Determination of mass attenuation coefficient, effective atomic number and effective electron density for tungsten alloys

被引:2
|
作者
机构
[1] Tellili, Borhan
[2] Elmahroug, Youssef
[3] Souga, Chedly
来源
Elmahroug, Y. (youssef_phy@hotmail.fr) | 1600年 / Inderscience Enterprises Ltd., 29, route de Pre-Bois, Case Postale 856, CH-1215 Geneva 15, CH-1215, Switzerland卷 / 08期
关键词
Chemical compositions - Cross-sections - Effective atomic number - Effective electron densities - Energy ranges - Incident photon energy - Mass attenuation coefficients;
D O I
10.1504/IJNEST.2014.063022
中图分类号
学科分类号
摘要
In this study, the mass attenuation coefficient, the effective atomic number and the effective electron density have been calculated for some tungsten alloys in the energy range from 100 keV to 100 GeV by using WinXCom program. The variation of these parameters with incident photon energy is shown graphically. The results show that all these parameters vary with the incident photon energy and the chemical composition. Copyright © 2014 Inderscience Enterprises Ltd.
引用
收藏
相关论文
共 50 条
  • [1] Studies on mass attenuation coefficient, effective atomic number and electron density of some vitamins
    D. Demir
    A. Turşucu
    T. Öznülüer
    [J]. Radiation and Environmental Biophysics, 2012, 51 : 469 - 475
  • [2] Studies on mass attenuation coefficient, effective atomic number and electron density of some vitamins
    Demir, D.
    Tursucu, A.
    Oznuluer, T.
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2012, 51 (04) : 469 - 475
  • [3] Measurements of mass attenuation coefficient, effective atomic number and electron density of some amino acids
    Kore, Prashant S.
    Pawar, Pravina P.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 98 : 86 - 91
  • [4] Pocket formula for mass attenuation coefficient, effective atomic number, and electron density of human tissues
    H. C. Manjunatha
    L. Seenappa
    [J]. Nuclear Science and Techniques, 2019, 30
  • [5] Pocket formula for mass attenuation coefficient, effective atomic number, and electron density of human tissues
    H.C.Manjunatha
    L.Seenappa
    [J]. Nuclear Science and Techniques, 2019, 30 (03) : 54 - 61
  • [6] Pocket formula for mass attenuation coefficient, effective atomic number, and electron density of human tissues
    Manjunatha, H. C.
    Seenappa, L.
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (03)
  • [7] Studies on mass attenuation coefficient, effective atomic number and electron density of some thermoluminescent dosimetric compounds
    Onder, P.
    Tursucu, A.
    Demir, D.
    Gurol, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 292 : 1 - 10
  • [8] The Direct-Zeff software for direct calculation of mass attenuation coefficient, effective atomic number and effective electron number
    Un, Adem
    Caner, Tanfer
    [J]. ANNALS OF NUCLEAR ENERGY, 2014, 65 : 158 - 165
  • [9] Variation of mass attenuation coefficient, effective atomic number, and electron density with incident photon energy of some organic acids
    Singh, Tejbir
    Kaur, Paramjeet
    Singh, Parjit S.
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 2007, 156 (02) : 229 - 243
  • [10] Accurate measurement of effective atomic number and electron density with X-ray attenuation coefficient spectrum
    Sakurai, H.
    Hoshi, K.
    Morimoto, I.
    Shiroto, Y.
    Ishizaki, K.
    Suzuki, K.
    Hasebe, Y.
    Ohno, Y.
    Torikoshi, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2023, 542 : 234 - 241