Evaluating newer generation intraocular lens calculation formulas in manual versus femtosecond laser-assisted cataract surgery

被引:2
|
作者
Harrish Nithianandan [1 ]
Soumya Sharma [2 ]
Eric S.Tam [3 ,4 ,5 ]
Hannah Chiu [3 ,4 ,5 ]
Rajiv Maini [4 ]
Sohel Somani [3 ,4 ,5 ]
机构
[1] Department of Ophthalmology & Visual Sciences, McGill University
[2] Ryerson University
[3] Department of Ophthalmology, University of Toronto
[4] Uptown Eye Specialists
[5] William Osler Health System
关键词
phacoemulsification; cataract; femtosecond laser; intraocular lens;
D O I
暂无
中图分类号
R779.6 [眼外科手术学];
学科分类号
100212 ;
摘要
AIM: To determine the refractive accuracy of the Haigis,Barrett Universal II(Barrett), and Hill-radial basis function 2.0(Hill-RBF) intraocular lens(IOL) power calculations formulas in eyes undergoing manual cataract surgery(MCS)and refractive femtosecond laser-assisted cataract surgery(Re LACS).METHODS: This was a REB-approved, retrospective interventional comparative case series of 158 eyes of 158 patients who had preoperative biometry completed using the IOL Master 700 and underwent implantation of a Tecnis IOL following uncomplicated cataract surgery using either MCS or ReLACS. Target spherical equivalence(SE) was predicted using the Haigis, Barrett, and Hill-RBF formulas.An older generation formula(Hoffer Q) was included in the analysis. Mean refractive error(ME) was calculated one month postoperatively. The lens factors of all formulas were retrospectively optimized to set the ME to 0 for each formula across all eyes. The median absolute errors(MedAE)and the proportion of eyes achieving an absolute error(AE)within 0.5 diopters(D) were compared between the two formulas among MCS and ReLACS eyes, respectively.RESULTS: Of the 158 eyes studied, 64 eyes underwent MCS and 94 eyes underwent ReLACS. Among MCS eyes,the MedAE did not differ between the formulas(P=0.59),however among ReLACS eyes, Barrett and Hill-RBF were more accurate(P=0.001). Barrett and Hill-RBF were both more likely to yield AE<0.5 D among both groups(P<0.001).CONCLUSION: The Barrett and Hill-RBF formula lead to greater refractive accuracy and likelihood of refractive success when compare to Haigis in eyes undergoing Re LACS.
引用
收藏
页码:1174 / 1178
页数:5
相关论文
共 50 条
  • [21] Femtosecond laser-assisted versus phacoemulsification for cataract extraction and intraocular lens implantation: clinical outcomes review
    Ewe, Shaun Y.
    Abell, Robin G.
    Vote, Brendan J.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (01) : 54 - 60
  • [22] Femtosecond laser-assisted intraocular lens exchange
    Fram, Nicole R.
    Masket, Samuel
    Alsetri, Hasan
    Pham, Don
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12): : E84 - E87
  • [23] Clinical Results of Femtosecond Laser-assisted Cataract Surgery in Eyes with Posterior Chamber Phakic Intraocular Lens
    Bang, Chan Woo
    Choi, Jae Won
    Han, Sang Youp
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (09): : 1035 - 1041
  • [24] Femtosecond laser-assisted cataract surgery for the white cataract
    Chee, Soon-Phaik
    Chan, Nicole Shu-Wen
    Yang, Younian
    Ti, Seng-Ei
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (04) : 544 - 550
  • [25] AN UMBRELLA REVIEW COMPARING THE SAFETY AND EFFECTIVENESS OF FEMTOSECOND LASER-ASSISTED CATARACT SURGERY WITH MANUAL CATARACT SURGERY
    Hsiao, C.
    Ferko, N.
    Ainslie-Garcia, M.
    Pan, S. M.
    Cheng, H.
    [J]. VALUE IN HEALTH, 2021, 24 : S224 - S224
  • [26] Incidence of cystoid macular edema in femtosecond laser-assisted cataract surgery compared with manual cataract surgery
    Oakley, Carmen
    Ewe, Shaun Y. P.
    Vote, Brendan J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1332 - 1332
  • [27] New intraocular lens designs for femtosecond laser-assisted cataract operations Chances and benefits
    Holland, Detlef
    Ruefer, Florian
    [J]. OPHTHALMOLOGE, 2020, 117 (05): : 424 - 430
  • [28] Higher Order Aberrations in Femtosecond Laser-Assisted Versus Manual Cataract Surgery: A Retrospective Cohort Study
    Ernest, Paul H.
    Popovic, Marko
    Schlenker, Matthew B.
    Klumpp, Lindsay
    Ahmed, Iqbal Ike K.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (02) : 102 - +
  • [29] Comparison of phacoemulsification parameters between manual and femtosecond laser-assisted cataract surgery
    Yesilirmak, Nilufer
    Diakonis, Vasilios F.
    Batlle, Juan F.
    Sayed-Ahmed, Ibrahim O.
    Davis, Zachary
    Waren, Daniel P.
    Yoo, Sonia H.
    O'Brien, Terrence P.
    Donaldson, Kendall E.
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (05): : 542 - 547
  • [30] Observation of Visual Quality after Femtosecond Laser-Assisted Cataract Surgery Combined with Trifocal Intraocular Lens Implantation
    Ma, Jianli
    Sun, Xuequan
    Liu, Yang
    Liu, Yumei
    [J]. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022