Corrosion Inhibition by Co-Immobilized Lysozyme and Lipase in Circulating Cooling Water System

被引:0
|
作者
Liu Fang [1 ]
Lü Yucui [1 ]
Jiang Guofei [1 ]
Chen Xiaorui [1 ]
Sun Juan [1 ]
Zhao Chaocheng [1 ]
机构
[1] State Key Laboratory of Petroleum Pollution Control, Department of Environmental and Safety Engineering, China University of Petroleum,Qingdao
基金
中国国家自然科学基金;
关键词
circulating cooling water; co-immobilization; lysozyme; lipase; corrosion inhibition;
D O I
暂无
中图分类号
Q814 [酶工程]; TE986 [油气加工设备的腐蚀与防护];
学科分类号
080706 ; 082203 ;
摘要
The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters were optimized by using the respond surface methodology(RSM). The corrosion inhibition performance of co-immobilized lipase and lysozyme was evaluated by weight loss measurements and electrochemical measurements. The results revealed that the optimal co-immobilization method should be the sequential immobilization of lysozyme and then lipase. The inhibition efficiency was 86.10% under the optimal co-immobilized conditions. Electrochemical data showed that co-immobilized lysozyme and lipase was a mixed-type inhibitor and the corrosion inhibition efficiency was 81%.
引用
收藏
页码:21 / 32
页数:12
相关论文
共 50 条
  • [21] Corrosion Inhibition of Carbon Steel in Cooling Water
    Hemmasian-Ettefagh, A.
    Amiri, M.
    Dehghanian, C.
    MATERIALS PERFORMANCE, 2010, 49 (03) : 60 - 65
  • [22] Phase-transited lysozyme nanofilm with co-immobilized copper ion and heparin as cardiovascular stent multifunctional coating
    Xu, Lehua
    He, Chenlong
    Yang, Shusheng
    Zhu, Yunxia
    Wang, Peng
    Wu, Shengming
    Guo, Fangfang
    Wang, Yilong
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2023, 230
  • [23] A MODEL SYSTEM OF COUPLED ACTIVITY OF CO-IMMOBILIZED CREATINE-KINASE AND MYOSIN
    ARRIODUPONT, M
    BECHET, JJ
    DALBIS, A
    EUROPEAN JOURNAL OF BIOCHEMISTRY, 1992, 207 (03): : 951 - 955
  • [24] Dynamic modelling of an integrated nitrogen removal system using Co-immobilized microorganisms
    dosSantos, VAPM
    Tramper, J
    Wijffels, RH
    IMMOBILIZED CELLS: BASICS AND APPLICATIONS, 1996, 11 : 486 - 493
  • [25] USE OF CO-IMMOBILIZED LYSOZYME AS A BACTERICIDE IN ENZYME COLUMNS - STEP TOWARD DESIGN OF SELF-STERILIZING ENZYME COLUMNS
    MATTIASSON, B
    BIOTECHNOLOGY AND BIOENGINEERING, 1977, 19 (05) : 777 - 780
  • [26] HYDROXYETHYLIDENEDIPHOSPHONIC ACID AS A CORROSION-INHIBITOR IN CIRCULATING COOLING WATER
    TESLYA, BM
    BURLOV, VV
    ERMOLINA, EY
    PROTECTION OF METALS, 1987, 23 (05): : 657 - 659
  • [27] ADVANCES IN IMMOBILIZED CELL-CULTURE - DEVELOPMENT OF CO-IMMOBILIZED MIXED CULTURE SYSTEM OF AEROBIC AND ANAEROBIC MICROORGANISMS
    KUROSAWA, H
    TANAKA, H
    PROCESS BIOCHEMISTRY, 1990, 25 (06) : 189 - 196
  • [28] Approaching environmental acceptability in cooling water corrosion inhibition
    Lake, D.L.
    Corrosion Prevention and Control, 1988, 35 (04): : 113 - 115
  • [29] A CIRCULATING WATER COOLING SYSTEM FOR A CAMAC CRATE
    PIERCE, WB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 286 - 290
  • [30] CO-IMMOBILIZED PYRUVATE-KINASE AND LACTATE-DEHYDROGENASE AS RECYCLING SYSTEM FOR ATP
    SLEGERS, G
    DELAET, S
    LAMBRECHT, RH
    BLOCK, C
    ENZYME AND MICROBIAL TECHNOLOGY, 1986, 8 (03) : 153 - 156