Developing a chloramine decay index to understand nitrification:A case study of two chloraminated drinking water distribution systems

被引:1
|
作者
Sina Moradi [1 ]
Sanly Liu [1 ]
Christopher W.K.Chow [2 ,3 ]
John van Leeuwen [3 ]
David Cook [2 ]
Mary Drikas [2 ]
Rose Amal [1 ]
机构
[1] School of Chemical Engineering,The University of New South Wales
[2] Australian Water Quality Centre,SA Water Corporation
[3] Centre for Water Management and Reuse,School of Natural and Built Environments,University of South Australia
基金
澳大利亚研究理事会;
关键词
HPSEC; Water distribution systems; Nitrification; Chloramine decay;
D O I
暂无
中图分类号
TU991.25 [饮水消毒、水生物防除];
学科分类号
摘要
The management of chloramine decay and the prevention of nitrification are some of the critical issues faced by water utilities that use chloramine as a disinfectant.In this study,potential association between high performance size exclusion chromatography(HPSEC)data obtained with multiple wavelength Ultraviolet(UV) detection from two drinking water distribution systems in Australia and nitrification occurrence was investigated.An increase in the absorbance signal of HPSEC profiles with UV detection at λ = 230 nm between apparent molecular weights of 200 to 1000 Da was observed at sampling sites that experienced rapid chloramine decay and nitrification while its absorbance signal at λ =254 nm decreased.A chloramine decay index(C.D.I) defined as the ratio of area beneath the HPSEC spectra at two different wavelengths of 230 and 254 nm,was used in assessing chloramine decay occurrences.The C.D.Is of waters at locations that experienced nitrification were consistently higher than locations not experiencing nitrification.A simulated laboratory study showed that the formation of nitrite/nitrate and/or soluble microbial products and/or the release of extracellular polymeric substances(EPS) during nitrification may contribute to the C.D.I.increase.These findings suggest that C.D.I derived from HPSEC with multiple wavelength UV detection could be an informative index to track the occurrence of rapid chloramine decay and nitrification.
引用
收藏
页码:170 / 179
页数:10
相关论文
共 50 条
  • [31] Relative importance of the phenomena responsible for chlorine decay in drinking water distribution systems
    Kiéné, L
    Lu, W
    Lévi, Y
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (06) : 219 - 227
  • [32] Evaluation of chlorine decay kinetics expressions for drinking water distribution systems modelling
    Kastl, GJ
    Fisher, IH
    Jegatheesan, V
    JOURNAL OF WATER SERVICES RESEARCH AND TECHNOLOGY-AQUA, 1999, 48 (06): : 219 - 226
  • [33] A comparative study of water quality using two quality indices and a risk index in a drinking water distribution network
    García-Ávila F.
    Zhindón-Arévalo C.
    Valdiviezo-Gonzales L.
    Cadme-Galabay M.
    Gutiérrez-Ortega H.
    del Pino L.F.
    Environmental Technology Reviews, 2022, 11 (01) : 49 - 61
  • [34] Using nitrification potential curves to evaluate full-scale drinking water distribution systems
    Fleming, Kala K.
    Harrington, Gregory W.
    Noguera, Daniel R.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2008, 100 (10): : 92 - +
  • [35] Using nitrification potential curves to evaluate full-scale drinking water distribution systems
    American Water, 1025 Laurel Oak Rd., Voorhees, NJ 08043, United States
    不详
    J Am Water Works Assoc, 2008, 10 (92-103+10):
  • [36] BLADDER-CANCER IN MASSACHUSETTS RELATED TO CHLORINATED AND CHLORAMINATED DRINKING-WATER - A CASE-CONTROL STUDY
    ZIERLER, S
    FEINGOLD, L
    DANLEY, RA
    CRAUN, G
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1988, 43 (02): : 195 - 200
  • [37] Evaluation of biological stability and corrosion potential in drinking water distribution systems: a case study
    C. C. Chien
    C. M. Kao
    C. W. Chen
    C. D. Dong
    H. Y. Chien
    Environmental Monitoring and Assessment, 2009, 153 : 127 - 138
  • [38] Evaluation of biological stability and corrosion potential in drinking water distribution systems: a case study
    Chien, C. C.
    Kao, C. M.
    Chen, C. W.
    Dong, C. D.
    Chien, H. Y.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2009, 153 (1-4) : 127 - 138
  • [39] The Case for Monitoring for Legionella pneumophila in Drinking Water Distribution Systems
    Lechevallier, Mark W.
    WATER, 2025, 17 (04)
  • [40] Bacterial regrowth in water distribution systems and its relationship to the water quality: Case study of two distribution systems in Korea
    Yoon, TH
    Lee, Y
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2004, 14 (02) : 262 - 267