Application of Cooling Water in Controlled Runout Table Cooling on Hot Strip Mill

被引:0
|
作者
LIU Zheng-dong [1 ]
I V Samarasekera [2 ]
机构
[1] Central Iron and Steel Research Institute
[2] University of British Columbia
关键词
cooling water; controlled runout table; hot strip mill;
D O I
10.13228/j.boyuan.issn1006-706x.2004.03.037
中图分类号
TG335.5 [板材、带材、箔材轧制];
学科分类号
080201 ; 080503 ;
摘要
The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to study the heat transfer by water jet impingement boiling during runout,apilot facility was constructed at the University of British Columbia.On this pilot facility,the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters,such as cooling water temperature,water jet impingement velocity,initial strip temperature,water flow rate,water nozzle diameter and array of water nozzles,on the heat transfer of heated strip.The results obtained contribute to the optimization of cooling water during runout.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 50 条
  • [31] Algorithm Design and Application of Laminar Cooling Feedback Control in Hot Strip Mill
    Liu En-yang
    Zhang Dian-hua
    Sun Jie
    Peng Liang-gui
    Gao Bai-hong
    Su Li-tao
    [J]. JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2012, 19 (04) : 39 - 42
  • [32] Algorithm Design and Application of Laminar Cooling Feedback Control in Hot Strip Mill
    En-yang Liu
    Dian-hua Zhang
    Jie Sun
    Liang-gui Peng
    Bai-hong Gao
    Li-tao Su
    [J]. Journal of Iron and Steel Research International, 2012, 19 : 39 - 42
  • [33] Online Monitor and Control of Cooling Temperature on Run-out Table of Hot Strip Mill
    Li, Hai-Jun
    Li, Li-Gang
    Li, Yong-Lin
    Wang, Guo-Dong
    [J]. STEEL RESEARCH INTERNATIONAL, 2015, 86 (11) : 1225 - 1233
  • [34] Simulation of accelerated strip cooling on the hot rolling mill run-out roller table
    Muhin, U.
    Belskij, S.
    Makarov, E.
    Koynov, T.
    [J]. FRATTURA ED INTEGRITA STRUTTURALE, 2016, (37): : 305 - 311
  • [35] EQUIPMENT FOR ACCELERATED COOLING OF STRIP ON DELIVERY TABLE OF 810 MILL
    GERTSEV, AI
    STEPANOV, BE
    SMIRNOV, VN
    KOBZAR, AI
    YASHKIN, EP
    [J]. STEEL IN THE USSR, 1979, 9 (07): : 357 - 358
  • [36] Modernization of the run-out table cooling control system at Krakatau Steel hot strip mill
    Bujang, F
    Driyono, J
    [J]. REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1997, 94 (7-8): : 901 - 906
  • [37] Receding Horizon Control for Hot Strip Mill Cooling Systems
    Hashimoto, Tomoaki
    Yoshioka, Yusuke
    Ohtsuka, Toshiyuki
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2013, 18 (03) : 998 - 1005
  • [38] Mathematic modeling on flexible cooling system in hot strip mill
    Peng Liang-gui
    Liu Xiang-hua
    Zhao Xian-ming
    Wu Di
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2014, 21 (01) : 43 - 49
  • [39] Development of Cooling Process Control Technique in Hot Strip Mill
    HAN Bin
    LIU Xiang-hua
    WANG Guo-dong
    SHE Guang-fu
    [J]. Journal of Iron and Steel Research(International), 2005, 12 (01) : 12 - 16
  • [40] Development of cooling process control technique in hot strip mill
    Han, B
    Liu, XH
    Wang, GD
    She, GF
    [J]. JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2005, 12 (01) : 12 - 16