Microstructural ordering of nanofibers in flow-directed assembly

被引:0
|
作者
GAO EnLai [1 ]
WANG ShiJun [1 ]
DUAN ChuanHua [2 ]
XU ZhiPing [1 ,3 ]
机构
[1] Applied Mechanics Laboratory, Department of Engineering Mechanics, and Center for Nano and Micro Mechanics,Tsinghua University
[2] Department of Mechanical Engineering, Boston University
[3] Applied Mechanics and Structure Safety Key Laboratory of Sichuan Province, School of Mechanics and Engineering,Southwest Jiaotong University
基金
中国国家自然科学基金;
关键词
nanofiber; nanostructured assemblies; shear flow; solvent evaporation; alignment; stacking order; densification; dissipative particle dynamics;
D O I
暂无
中图分类号
TQ340.1 [基础理论]; TB383.1 [];
学科分类号
摘要
Fabrication of highly ordered and dense nanofibers assemblies is of key importance for high-performance and multi-functional material and device applications. In this work, we design an experimental approach in silico, where shear flow and solvent evaporation are applied to tune the alignment, overlap of nanofibers, and density of the assemblies. Microscopic dynamics of the process are probed by dissipative particle dynamics simulations, where hydrodynamic and thermal fluctuation effects are fully modeled. We find that microstructural ordering of the assembled nanofibers can be established within a specific range of the Peclet numbers and evaporation rates, while the properties of nanofibers and their interaction are crucial for the local stacking order. The underlying mechanisms are elucidated by considering the competition between hydrodynamic coupling and thermal fluctuation. Based on these understandings, a practical design of flow channels for nanofiber assembly with promising mechanical performance is outlined.
引用
收藏
页码:1545 / 1554
页数:10
相关论文
共 50 条
  • [41] EXERCISE ELECTROCARDIOGRAPHY AND FLOW-DIRECTED RIGHT HEART CATHETERIZATION IN FEMALES
    HAERER, W
    BAUER, U
    FRICK, G
    HERZ KREISLAUF, 1984, 16 (06): : 299 - 303
  • [42] BEDSIDE FLOW-DIRECTED BALLOON CATHETERIZATION IN THE CRITICALLY ILL PATIENT
    MILLEN, JE
    GLAUSER, FL
    MEDICAL COLLEGE OF VIRGINIA QUARTERLY, 1978, 14 (04): : 172 - 175
  • [43] DISTAL SPLENIC ARTERY EMBOLIZATION WITH A FLOW-DIRECTED BALLOON CATHETER
    MAZER, M
    SMITH, CW
    MARTIN, VN
    RADIOLOGY, 1985, 154 (01) : 245 - 245
  • [44] INTRACARDIAC KNOTTING OF A FLOW-DIRECTED BALLOON-TIPPED CATHETER
    FIBUCH, EE
    TUOHY, GF
    ANESTHESIA AND ANALGESIA, 1980, 59 (03): : 217 - 219
  • [45] FLOW-DIRECTED USE OF ELECTROLYTICALLY DETACHABLE PLATINUM EMBOLIZATION COILS
    TEITELBAUM, GP
    HIGASHIDA, RT
    HALBACH, VV
    LARSEN, DW
    MCDOUGALL, CG
    DOWD, CF
    HIESHIMA, GB
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (03) : 453 - 456
  • [46] PULMONARY COMPLICATIONS OF FLOW-DIRECTED BALLOON-TIPPED CATHETER
    FOOTE, GA
    SCHABEL, SI
    HODGES, M
    NEW ENGLAND JOURNAL OF MEDICINE, 1974, 290 (17): : 927 - 931
  • [47] COMPLICATION OF THE REUSE OF FLOW-DIRECTED PULMONARY-ARTERY CATHETERS
    PARK, GR
    SCOTT, DHT
    BRITISH MEDICAL JOURNAL, 1982, 284 (6311): : 258 - 259
  • [48] FLOW-DIRECTED CATHETER FOR SUPERSELECTIVE ARTERIAL CATHETERIZATION - AN EXPERIMENTAL EVALUATION
    WRIGHT, KC
    WALLACE, S
    CHARNSANGAVEJ, C
    LEE, YY
    CARRASCO, CH
    GIANTURCO, C
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1986, 9 (01) : 54 - 56
  • [49] COMPLICATIONS ASSOCIATED WITH BALLOON-TIPPED, FLOW-DIRECTED CATHETERS
    NICHOLS, WW
    NICHOLS, MA
    BARBOUR, H
    HEART & LUNG, 1979, 8 (03): : 503 - 506
  • [50] FLOW-DIRECTED ATRIAL CATHETER PLACEMENT FOR VENTRICULOATRIAL SHUNTS - TECHNICAL NOTE
    BARKER, FG
    TATTER, SB
    NEUROSURGERY, 1994, 35 (03) : 534 - 535