Thiocyanate ion selective electrode based on bis(N-3-methylphenyl salicylidenaminato)copper(Ⅱ) ionophore

被引:0
|
作者
A.Benvidi [1 ]
M.T.Ghanbarzadeh [1 ]
M.Dehghan [1 ]
M.Mazloum-Ardakani [1 ]
R.Vafazadeh [1 ]
机构
[1] Department of Chemistry,Faculty of Science,Yazd University
关键词
Thiocyanate; PVC membrane electrode; Potentiometric determination; lonophore;
D O I
暂无
中图分类号
O646.54 [电极过程];
学科分类号
081704 ;
摘要
In this work a PVC membrane electrode based on bis(N-3-methyl phenyl salicylidenaminato)copper(II)as ionophore was prepared.The electrode was tested by inorganic anions and showed good selectivity for thiocyanate ion.This sensor showed Nerstian behavior with a slope of a-59.3 mV per decade at 25℃.The proposed electrode exhibited a wide linear range from 1.0 × 10mol/L to 1.0× 10mol/L with a detection limit of 5.0×10mol/L.The electrode response was independent of pH in the range of 4.0-10.0.The response time is about 9-21s,and the electrode can be used for over 60 days without considerable deterioration.The prepared sensor was applied as an indicator electrode in potentiometric titration of SCN with Ag~+ ion and to determine the thiocyanate in samples of urine and saliva.
引用
收藏
页码:1639 / 1642
页数:4
相关论文
共 50 条
  • [31] A selective membrane electrode for Lanthanum(III) ion based on a hexaaza macrocycle derivative as ionophore
    Singh, Ashok Kumar
    Saxena, Puja
    Mehtab, Sameena
    Gupta, Barkha
    ANALYTICAL SCIENCES, 2006, 22 (10) : 1339 - 1344
  • [32] A Selective Membrane Electrode for Lanthanum(III) Ion Based on a Hexaaza Macrocycle Derivative as Ionophore
    Ashok Kumar Singh
    Puja Saxena
    Sameena Mehtab
    Barkha Gupta
    Analytical Sciences, 2006, 22 : 1339 - 1344
  • [33] Voltammetric determination of phosphates using ion-selective electrode based on organotin ionophore
    Martynov, Leonid Yu.
    Sergeeva, Anastasia S.
    Sakharov, Konstantin A.
    Shkinev, Valery M.
    Yashtulov, Nikolai A.
    Zaitsev, Nikolai K.
    MICROCHEMICAL JOURNAL, 2023, 191
  • [34] Performance evaluation of copper ion selective electrode based on cyanocopolymers
    Gupta, KC
    D'Arc, MJ
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (03) : 171 - 176
  • [35] Coated-wire copper(II)-selective electrode based on phenylglyoxal-α-monoxime ionophore
    A. Firooz
    M. Mazloum
    J. Safari
    M. Amini
    Analytical and Bioanalytical Chemistry, 2002, 372 : 718 - 722
  • [36] Salicylate-selective Potential Response of an Electrode Based on a Copper(II)-phthalocyanine Derivative as an Ionophore
    Xu Wenju
    Yuan Ruo
    Chai Yaqin
    CHINESE JOURNAL OF CHEMISTRY, 2009, 27 (01) : 99 - 104
  • [37] Novel thiocyanate-selective membrane sensor based on crown ether-cetyltrimethyl ammonium thiocyanate ion-pair as a suitable ionophore
    Arvand, M.
    Zanjanchi, M. A.
    Heydari, L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01): : 301 - 308
  • [38] Liquid membrane transport and silver selective electrode based on novel bis(3-pyridinecarboxylate) calix[4]arene as ionophore
    Liu, Y
    Zhao, BT
    Chen, LX
    He, XW
    MICROCHEMICAL JOURNAL, 2000, 65 (01) : 75 - 79
  • [39] Reflectance chemosensor based on bis-thiourea derivative as ionophore for copper(II) ion detection
    Razak, Nurul Hidayah Abdul
    Tan, Ling Ling
    Hasbullah, Siti Aishah
    Heng, Lee Yook
    MICROCHEMICAL JOURNAL, 2020, 153
  • [40] Highly thiocyanate-selective membrane electrodes based on the N,N′-bis-(benzaldehyde)-glycine copper(II) complex as a neutral carrier
    Chai, YQ
    Dai, JY
    Yuan, R
    Zhong, X
    Liu, Y
    Tang, DP
    DESALINATION, 2005, 180 (1-3) : 207 - 215