Strip line beam position monitor for HLS LINAC

被引:1
|
作者
LI Ji-Hao*
机构
关键词
Beam position monitor; Strip line; Reflection; Coupling; Sensitivity;
D O I
暂无
中图分类号
TL506 [加速器参数的测量];
学科分类号
摘要
The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the original interceptive fluorescent target. This paper gives out the theoretical analysis and bench test result of the strip line BPM. The BPM has a characteristic impedance of (50±5)?, a reflection coefficient of less than –4 dB, a band-width of 400 MHz, a coupling coefficient of less than -15 dB, and a sensitivity of 1.16 dB/mm. Additionally, the strip line BPM has a good linearity.
引用
收藏
页码:257 / 259
页数:3
相关论文
共 50 条
  • [41] Rogowski Beam Position Monitor
    Suvarna, Rahul
    Nass, Alexander
    Rathmann, Frank
    Soltner, Helmut
    Pretz, Joerg
    19TH WORKSHOP ON POLARIZED SOURCES, TARGETS AND POLARIMETRY, 2023,
  • [42] Output beam energy measurement of a 100-MeV KOMAC drift tube linac by using a stripline beam position monitor
    Han-Sung Kim
    Journal of the Korean Physical Society, 2015, 67 : 1382 - 1386
  • [43] Output beam energy measurement of a 100-MeV KOMAC drift tube linac by using a stripline beam position monitor
    Kim, Han-Sung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (08) : 1382 - 1386
  • [44] First demonstration of simultaneous measurement of beam current, beam position, and beam tilt on induction linac using combined B-dot monitor
    He, Xiaozhong
    Pang, Jian
    Chen, Nan
    Li, Qin
    Dai, Wenhua
    Ma, Chaofan
    Zhao, Liangchao
    Gao, Feng
    Dai, Zhiyong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (06):
  • [45] BEAM CURRENT AND POSITION MONITORS AT NBS LINAC
    MENKE, JL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (02): : 262 - +
  • [46] BEAM CURRENT AND POSITION MONITORS AT NBS LINAC
    MENKE, JL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1971, NS18 (03) : 909 - &
  • [47] A Beam-Induced Fluorescence Monitor at the Low-Energy Beam Transport Line of the Proton Linac at the Institute for Nuclear Research
    Gavrilov, S. A.
    Kalinin, Yu. G.
    Polonik, I. I.
    Titov, A. I.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2024, 67 (SUPPL2) : S167 - S173
  • [48] The upgrade of HLS linac control system
    Liu, G
    Li, W
    Li, C
    Li, J
    Chen, L
    Bao, X
    Wang, J
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2357 - 2359
  • [49] Design and upgrading of HLS Linac modulators
    Shang, L
    Luo, XF
    Wang, W
    Hong, J
    Lu, YM
    Zhang, Y
    Zhao, F
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 (12): : 1133 - 1137
  • [50] Nondestructive beam energy-spread monitor using multi-strip-line electrodes
    Suwada, T
    Satoh, M
    Furukawa, K
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2003, 6 (03):