Real-Time Vivo Tooth Mobility Measurement and Analysis

被引:0
|
作者
Richter EJ
机构
[1] Germany
[2] Prothetik
[3] Uni-Wuerzburg
[4] Zahnklinik
关键词
Tooth Mobility; Optical Fiber; Displacement Sensor; Vivo Measurement;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The significance and research status of tooth mobility (TM) measurement are introduced. There are many methods to measure the TM, but up to now no one does vivo dynamic TM measurement. An optical-electronic method is raised to measure it in this paper. The measurement theory is introduced and a measurement system is setup. Special proceeding is done for this measurement because of the small oral cavity measurement area. It is the first time to get vivo dynamic TM measurement result at last. The measurement result is analysed and a new movement period is discovered. It shows that this method satisfies for the dynamical tooth movement. Further research is suggested.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 50 条
  • [1] REAL-TIME MEASUREMENT OF HUMAN TOOTH ERUPTION WITH MOIRE MAGNIFICATION
    TRENTINI, CJ
    GIERIE, WV
    PROFFIT, WR
    [J]. JOURNAL OF DENTAL RESEARCH, 1995, 74 : 255 - 255
  • [2] Real-time analysis of apoptosis in vivo
    Lee, P
    Segal, MS
    [J]. CYTOMETRY, 4TH EDITION: NEW DEVELOPMENTS, 2004, 75 : 343 - 354
  • [3] Computer image analysis for real-time measurement of microvessel diameter in vivo and in vitro.
    Neild, T
    [J]. JOURNAL OF VASCULAR RESEARCH, 1998, 35 : 73 - 73
  • [4] Recent advances in the real-time, in vivo measurement of drugs and biomarkers
    Plaxco, K. W.
    [J]. CLINICA CHIMICA ACTA, 2024, 558
  • [6] REAL-TIME CONTOURING OF TOOTH IMPRINTS
    JONGSMA, FHM
    RUISSEN, KJ
    LAMBRECHTS, P
    VANHERLE, G
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 492 : 500 - 506
  • [7] Real-time measurement of in vitro enamel demineralization in the vicinity of the restoration–tooth interface
    S. E. P. Dowker
    P. Anderson
    J. C. Elliott
    [J]. Journal of Materials Science: Materials in Medicine, 1999, 10 : 379 - 382
  • [8] In vivo real-time measurement of nitric oxide in anesthetized rat brain
    Barbosa, Rui M.
    Lourenco, Catia F.
    Santos, Ricardo M.
    Pomerleau, Francois
    Huettl, Peter
    Gerhardt, Greg A.
    Laranjinha, Joao
    [J]. NITRIC OXIDE, PT G: OXIDATIVE AND NITROSATIVE STRESS IN REDOX REGULATION OF CELL SIGNALING, 2008, 441 : 351 - 367
  • [9] A needle temperature microsensor for in vivo and real-time measurement of the temperature in acupoints
    Cui, RF
    Liu, JH
    Ma, WT
    Hu, HB
    Zhou, XD
    Li, HY
    Hu, JM
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2005, 119 (01) : 128 - 132
  • [10] REAL-TIME MEASUREMENT AND ANALYSIS OF HARMONICS IN POWER SYSTEMS
    Demirbas, Sevki
    Bayhan, Sertac
    [J]. JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2009, 24 (03): : 461 - 468