In vivo real-time measurement of nitric oxide in anesthetized rat brain

被引:56
|
作者
Barbosa, Rui M.
Lourenco, Catia F.
Santos, Ricardo M.
Pomerleau, Francois
Huettl, Peter
Gerhardt, Greg A.
Laranjinha, Joao
机构
关键词
D O I
10.1016/S0076-6879(08)01220-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
During the last two decades nitric oxide (center dot NO) gas has emerged as a novel and ubiquitous intercellular modulator of cell functions. In the brain, center dot NO is implicated in mechanisms of synaptic plasticity but it is also involved in cell death pathways underlying several neurological diseases. Because of its hydrophobicity, small size, and rapid diffusion properties,the rate and pattern of center dot NO concentration changes are critical determinants for the understanding of its diverse actions in the brain. center dot NO measurement in vivo has been a challenging task due to its low concentration, short half-life, and high reactivity with other biological molecules, such as superoxide radical, thiols, and heme proteins. Electrochemical methods are versatile approaches for detecting and monitoring various neurotransmitters. When associated with microelectrodes inserted into the brain they provide high temporal and spatial resolution, allowing measurements of neurochemicals in physiological environments in a real-time fashion. To date, electrochemical detection of center dot NO is the only available technique that provides a high sensitivity, low detection limit, selectivity, and fast response to measure the concentration dynamics of center dot NO in vivo. We have used carbon fiber microelectrodes coated with two layers of Nafion and o-phenylenediamine to monitor the rate and pattern of center dot NO change in the rat brain in vivo. The analytical performance of microelectrodes was assessed in terms of sensitivity, detection limit, and selectivity ratios against major interferents: ascorbate, dopamine, noradrenaline, serotonin, and nitrite. For the in vivo recording experiments, we used a microelectrode/micropipette array inserted into the brain using a stereotaxic frame. The characterization of in vivo signals was assessed by electrochemical and pharmacological verification. Results support our experimental conditions that the measured oxidation current reflects variations in the center dot NO concentration in brain extracellular space. We report results from recordings in hippocampus and striatum upon stimulation of N-methyl-D-aspartate-subtype glutamate receptors. Moreover, the kinetics of center dot NO disappearance in vivo following pressure ejection of a center dot NO solution is also addressed.
引用
收藏
页码:351 / 367
页数:17
相关论文
共 50 条
  • [1] In vivo real-time measurement of nitric oxide generation in the rat gastrointestinal tract
    Tanaka, T
    Uneyama, H
    Yoshie, S
    Torii, K
    [J]. JOURNAL OF PHARMACOLOGICAL SCIENCES, 2004, 94 : 258P - 258P
  • [2] In vivo concentration dynamics of nitric oxide in anesthetized rat brain
    Lourenco, C. F.
    Santos, R. M.
    Gerhard, G. A.
    Barbosa, R. M.
    Laranjinha, J.
    [J]. FREE RADICAL RESEARCH, 2008, 42 : S49 - S49
  • [3] Real-time monitoring of nitric oxide in rat hippocampal brain slices
    Laranjinha, J
    Ledo, A
    Frade, J
    Barbosa, RM
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 2002, 33 : S194 - S194
  • [4] Real time in vivo measurement of nitric oxide concentration dynamics in the rat hippocampus
    Santos, Ricardo M.
    Lourenco, Cataia F.
    Gerhardt, Greg A.
    Laranjinha, Joao
    Barbosa, Rui M.
    [J]. FREE RADICAL RESEARCH, 2007, 41 : S53 - S53
  • [5] Direct Real-Time Measurement of Intra-Oocyte Nitric Oxide Concentration In Vivo
    Goud, Pravin T.
    Goud, Anuradha P.
    Najafi, Tohid
    Gonik, Bernard
    Diamond, Michael P.
    Saed, Ghassan M.
    Zhang, Xueji
    Abu-Soud, Husam M.
    [J]. PLOS ONE, 2014, 9 (06):
  • [6] The challenge of real-time measurements of nitric oxide release in the brain
    Wang, S.
    Paton, J. F. R.
    Kasparov, S.
    [J]. AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2006, 126 : 59 - 67
  • [7] The real-time in vivo electrochemical measurement of nitric oxide and carbon monoxide release upon direct epidural electrical stimulation of the rat neocortex
    Park, Sarah S.
    Hong, Minyoung
    Ha, Yejin
    Sim, Jeongeun
    Jhon, Gil-Ja
    Lee, Youngmi
    Suh, Minah
    [J]. ANALYST, 2015, 140 (10) : 3415 - 3421
  • [8] A sub-nanomolar real-time nitric oxide probe:: in vivo nitric oxide release in heart
    Mantione, KJ
    Stefano, GB
    [J]. MEDICAL SCIENCE MONITOR, 2004, 10 (04): : MT47 - MT49
  • [9] Real-time measurement of nitric oxide during surgery with cardiopulmonary bypass
    Yamasawa, T
    Hamanaka, S
    Inagaki, E
    Mochizuki, S
    Goto, M
    Miyasaka, T
    Ogasawara, Y
    Kawano, Y
    Kawamur, I
    Tanemoto, K
    [J]. NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2004, 11 (01): : 124 - 124
  • [10] Fluorescent probes for real-time measurement of nitric oxide in living cells
    Li, Huili
    Wan, Ajun
    [J]. ANALYST, 2015, 140 (21) : 7129 - 7141