Determination of PCDD/Fs and dioxin-like PCBs in food and feed using gas chromatography-triple quadrupole mass spectrometry

被引:0
|
作者
Huizhong Sun [1 ,2 ]
Pu Wang [1 ]
Honghua Li [1 ]
Yingming Li [1 ]
Shucheng Zheng [1 ,2 ]
Julius Matsiko [1 ,2 ]
Yanfen Hao [1 ,2 ]
Weiwei Zhang [1 ,2 ]
Dou Wang [1 ,2 ]
Qinghua Zhang [1 ,2 ,3 ]
机构
[1] State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences
[2] University of Chinese Academy of Sciences
[3] Institute of Environment and Health, Jianghan University
基金
中国国家自然科学基金;
关键词
PCDD/Fs; DL-PCBs; food; feed; GC-MS/MS;
D O I
暂无
中图分类号
TS207.5 [食品污染度的测定]; O657.63 [质谱分析]; S816.17 [饲料检验方法];
学科分类号
070302 ; 081704 ; 083201 ; 090502 ;
摘要
A method was developed on a gas chromatograph coupled to a triple quadrupole mass spectrometer(GC-MS/MS) for trace level determination of polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs) and dioxin-like polychlorinated biphenyls(DL-PCBs) in food and feed. The results demonstrated good sensitivity and repeatability for PCDD/Fs and DL-PCBs at an extremely low level(10 pg mL;for 2,3,7,8-TCDD/F), as well as wide linear response of over 3 or 4 orders of magnitude in concentration ranges; 0.5–200 ng mL;for PeCDD/F and 0.2–2000 ng mL;for DL-PCBs. The method detection limits for PCDD/Fs and DL-PCBs were in the range from 0.018–0.17 pg g;to 0.13–0.36 pg g;, respectively. The performance of the GC-MS/MS for food and feed sample analysis showed high precision and accuracy compared to the high resolution gas chromatograph/high resolution mass spectrometer. The results indicated the feasibility of GC-MS/MS as a confirmatory method for the measurement of PCDD/Fs and DL-PCBs in food and feed as required by European Union legislation.
引用
收藏
页码:670 / 677
页数:8
相关论文
共 50 条
  • [31] Determination of PCDD/Fs and dioxin-like PCBs in fish oils for feed ingredients by congener-specific chemical analysis and CALUX bioassay
    Hasegawa, Jun
    Guruge, Keerthi S.
    Seike, Nobuyasu
    Shirai, Yuji
    Yamata, Toshiaki
    Nakamura, Masafumi
    Handa, Hiroshi
    Yamanaka, Noriko
    Miyazaki, Shigeru
    CHEMOSPHERE, 2007, 69 (08) : 1188 - 1194
  • [32] PCDD/Fs, dioxin-like, and non-dioxin like PCBs in the sediments of high Arctic fjords, Svalbard
    Kannan, V. M.
    Gopikrishna, V. G.
    Saritha, V. K.
    Krishnan, K. P.
    Mohan, Mahesh
    MARINE POLLUTION BULLETIN, 2022, 174
  • [33] Gas Chromatography-Triple Quadrupole Mass Spectrometry Analysis of Dioxins in Soil
    Kwon, Young Sang
    Choi, Sung-Gil
    Lee, Seung-Min
    Kim, Jong-Hwan
    Seo, Jong-Su
    ACTA CHROMATOGRAPHICA, 2019, 31 (03) : 235 - 240
  • [34] PCDD/Fs and dioxin-like PCBs in sediment and biota from the Mondego estuary (Portugal)
    Nunes, Margarida
    Marchand, Philippe
    Vernisseau, Anais
    Le Bizec, Bruno
    Ramos, Fernando
    Pardal, Miguel A.
    CHEMOSPHERE, 2011, 83 (10) : 1345 - 1352
  • [35] Estimation and characterization of PCDD/Fs and dioxin-like PCBs from Chinese iron foundries
    Lv, Pu
    Zheng, Minghui
    Liu, Guorui
    Liu, Wenbin
    Xiao, Ke
    CHEMOSPHERE, 2011, 82 (05) : 759 - 763
  • [36] Validation of the CALUX bioassay for the screening of PCDD/Fs and dioxin-like PCBs in retail fish
    Tsutsumi, T
    Amakura, Y
    Nakamura, M
    Brown, DJ
    Clark, GC
    Sasaki, K
    Toyoda, M
    Maitani, T
    ANALYST, 2003, 128 (05) : 486 - 492
  • [37] Simulatneous determination of nitrapyrin and its metabolite residues in food crops by derivatization with gas chromatography-triple quadrupole mass spectrometry
    Sun Linghui
    Chen Jie
    Xu Juan
    Li Minqing
    Chen Wenrui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (06) : 695 - 701
  • [38] Quick determination of fipronil and its metabolites in eggs by gas chromatography-triple quadrupole mass spectrometry
    Deng Wujian
    Wu Weidong
    Zhao Xu
    Liang Hong
    Liang Shuwen
    Jin Baohui
    Wang Shen
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (06) : 547 - 551
  • [39] Simultaneous determination of 17 phthalate esters in Shengmaiyin by gas chromatography-triple quadrupole mass spectrometry
    Zhang Li
    Shang Chuxiang
    Sun Cheng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (06) : 653 - 657
  • [40] Rapid determination of sildenafil and its analogues in dietary supplements using gas chromatography-triple quadrupole mass spectrometry
    Mokhtar, S. U.
    Chin, S. -T.
    Kee, C. -L.
    Low, M. -Y.
    Drummer, O. H.
    Marriott, P. J.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 121 : 188 - 196