A modified interval subdividing based geometric calibration method for interior tomography

被引:0
|
作者
张峰 [1 ]
闫镔 [1 ]
李磊 [1 ]
席晓琦 [1 ]
江桦 [1 ]
机构
[1] National Digital Switching System Engineering & Technology Research Center
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
interior tomography; geometric calibration; interval subdividing; minimum interval;
D O I
暂无
中图分类号
O435 [几何光学];
学科分类号
070207 ; 0803 ;
摘要
The interior tomography is commonly met in practice, whereas the self-calibration method for geometric parameters remains far from explored. To determine the geometry of interior tomography, a modified interval subdividing based method, which was originally developed by Tan et al.,[11]was presented in this paper. For the self-calibration method, it is necessary to obtain the reconstructed image with only geometric artifacts. Therefore, truncation artifacts reduction is a key problem for the self-calibration method of an interior tomography. In the method, an interior reconstruction algorithm instead of the Feldkamp–Davis–Kress(FDK) algorithm was employed for truncation artifact reduction. Moreover, the concept of a minimum interval was defined as the stop criterion of subdividing to ensure the geometric parameters are determined nicely. The results of numerical simulation demonstrated that our method could provide a solution to the selfcalibration for interior tomography while the original interval subdividing based method could not. Furthermore, real data experiment results showed that our method could significantly suppress geometric artifacts and obtain high quality images for interior tomography with less imaging cost and faster speed compared with the traditional geometric calibration method with a dedicated calibration phantom.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 50 条
  • [41] Accurate and robust calibration method based on pattern geometric constraints for fringe projection profilometry
    Lu, Peng
    Sun, Changku
    Liu, Bin
    Wang, Peng
    APPLIED OPTICS, 2017, 56 (04) : 784 - 794
  • [42] Geometric calibration method based on a two-dimensional turntable for a directional polarimetric camera
    Huang, Chan
    Meng, Binghuan
    Chang, Yuyang
    Chen, Feinan
    Zhang, Miaomiao
    Han, Lin
    Xiang, Guangfeng
    Tu, Bihai
    Hong, Jin
    APPLIED OPTICS, 2020, 59 (01) : 226 - 233
  • [43] Geometric calibration method based on Euler transformation for a large field of view polarimetric imager
    Huang, Chan
    Chang, Yuyang
    Han, Lin
    Wu, Su
    Li, Shuang
    Luo, Donggen
    Sun, Liang
    Hong, Jin
    JOURNAL OF MODERN OPTICS, 2020, 67 (20) : 1524 - 1533
  • [44] Research on Calibration Method of Line-Structured Light Based on Multiple Geometric Constraints
    Li, Chunfeng
    Xu, Xiping
    Ren, Zhen
    Liu, Siyuan
    APPLIED SCIENCES-BASEL, 2023, 13 (10):
  • [45] Fuzzy analysis of geometric tolerances using interval method
    Wu, W.
    Rao, S. S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2006, 220 (04) : 489 - 497
  • [46] High Order Total Variation Method for Interior Tomography
    Yang, Jiansheng
    Yu, Hengyong
    Cong, Wenxiang
    Jiang, Ming
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [47] MODIFIED METHOD FOR CALIBRATION OF WARBURG MANOMETERS
    TIEMAN, JW
    BECK, JV
    EXPERIENTIA, 1951, 7 (10): : 389 - 389
  • [48] An efficient method of wavelength interval selection based on random frog for multivariate spectral calibration
    Yun, Yong-Huan
    Li, Hong-Dong
    Wood, Leslie R. E.
    Fan, Wei
    Wang, Jia-Jun
    Cao, Dong-Sheng
    Xu, Qing-Song
    Liang, Yi-Zeng
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 111 : 31 - 36
  • [49] A calibration-based method for interval reliability analysis of the multi-manipulator system
    Wang, Wei
    Liu, Shuangyao
    Wang, Jin
    Lu, Guodong
    EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2022, 24 (01): : 42 - 52
  • [50] CALIBRATION OF THERMOCOUPLES BY A MODIFIED WIRE METHOD
    LASEK, J
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1973, 23 (05) : 581 - 584