A modified interval subdividing based geometric calibration method for interior tomography

被引:0
|
作者
张峰 [1 ]
闫镔 [1 ]
李磊 [1 ]
席晓琦 [1 ]
江桦 [1 ]
机构
[1] National Digital Switching System Engineering & Technology Research Center
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
interior tomography; geometric calibration; interval subdividing; minimum interval;
D O I
暂无
中图分类号
O435 [几何光学];
学科分类号
070207 ; 0803 ;
摘要
The interior tomography is commonly met in practice, whereas the self-calibration method for geometric parameters remains far from explored. To determine the geometry of interior tomography, a modified interval subdividing based method, which was originally developed by Tan et al.,[11]was presented in this paper. For the self-calibration method, it is necessary to obtain the reconstructed image with only geometric artifacts. Therefore, truncation artifacts reduction is a key problem for the self-calibration method of an interior tomography. In the method, an interior reconstruction algorithm instead of the Feldkamp–Davis–Kress(FDK) algorithm was employed for truncation artifact reduction. Moreover, the concept of a minimum interval was defined as the stop criterion of subdividing to ensure the geometric parameters are determined nicely. The results of numerical simulation demonstrated that our method could provide a solution to the selfcalibration for interior tomography while the original interval subdividing based method could not. Furthermore, real data experiment results showed that our method could significantly suppress geometric artifacts and obtain high quality images for interior tomography with less imaging cost and faster speed compared with the traditional geometric calibration method with a dedicated calibration phantom.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 50 条
  • [1] A modified interval subdividing based geometric calibration method for interior tomography
    Zhang Feng
    Yan Bin
    Li Lei
    Xi Xiao-Qi
    Jiang Hua
    CHINESE PHYSICS B, 2014, 23 (09)
  • [2] An interval subdividing based method for geometric calibration of cone-beam CT
    Tan, Shengqi
    Cong, Peng
    Liu, Ximing
    Wu, Zhifang
    NDT & E INTERNATIONAL, 2013, 58 : 49 - 55
  • [3] Fast cone-beam computed tomography geometric calibration method based on measuring tools
    Zhang C.
    Huang K.
    Chen H.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (01): : 175 - 182
  • [4] A new thermochemical method for subdividing accurately a given interval on the thermometer scale
    Richards, TW
    Thorvaldson, T
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1915, 37 : 81 - 86
  • [5] A novel method of micro-tomography geometric angle calibration with random phantom
    Li, Haocheng
    Hong, Wei
    Liu, Yu
    Mou, Xuanqin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (04) : 641 - 652
  • [6] A Method Based on Two Constraints for Camera Calibration Interior Parameters
    Du Yefei
    Dong Mingli
    Wang Jun
    Sun Peng
    ADVANCES IN PRECISION INSTRUMENTATION AND MEASUREMENT, 2012, 103 : 181 - 186
  • [7] Self-calibration Method for Robot Based on Geometric Constraints
    Shi, Jingfei
    Zhang, Hongsheng
    Liu, Yuan
    Wang, Daqing
    Gao, Lifu
    2016 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2016, : 1863 - 1867
  • [8] A geometric calibration method for inverse geometry computed tomography using P-matrices
    Slagowski, Jordan M.
    Dunkerley, David A. P.
    Hatt, Charles R.
    Speidel, Michael A.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [9] Improved and Modified Geometric Formulation of POE Based Kinematic Calibration of Serial Robots
    Lou, Yunjiang
    Chen, Tieniu
    Wu, Yuanqing
    Li, Zhibin
    Jiang, Shilong
    2009 IEEE-RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, 2009, : 5261 - +
  • [10] Geometric misalignment and calibration in cone-beam tomography
    von Smekal, L
    Kachelriess, M
    Stepina, E
    Kalender, WA
    MEDICAL PHYSICS, 2004, 31 (12) : 3242 - 3266