Value of digital subtraction angiography in endovascular graft exclusion for abdominal aortic aneurysms

被引:0
|
作者
赵珺
景在平
王震堂
叶华
包俊敏
赵志青
冯翔
曲乐丰
陆清声
叶必远
机构
关键词
digital subtraction angiography; aortic aneurysm; abdominal; endovascular graft exclusion;
D O I
暂无
中图分类号
R543.1 [主动脉疾病];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the value of digital subtraction angiography (DSA) in management of endovascular graft exclusion (EVGE) for abdominal aortic aneurysms. Methods: Monitored by DSA and fluoroscopy, stent-graft complex were introduced into the aneurysm sac via femoral arteries and were deployed at the proximal and distal necks to exclude the sac from circulation. Results: The success rate of deployment was 94. 74% (36/38). Endoleaks occurred in 4 cases. One converted to open surgery because of sac rupture 4 days after deployment. Thrombosis and stenosis occurred in 2 cases. Three patients died shortly after the operation (< 3 months). Conclusion: DSA can monitor EVCE on real-time throughout the whole procedure. It can meet the needs of measurement, location, evaluating, detecting, and also can be much helpful in correcting complications. Moreover, it provides large visual field and operating space, and is a very important monitoring method for EVGE.
引用
收藏
页码:13 / 16
页数:4
相关论文
共 50 条
  • [41] Abdominal Aortic Aneurysms: Endovascular Repair
    Jim, Jeffrey
    Sanchez, Luis A.
    [J]. MOUNT SINAI JOURNAL OF MEDICINE, 2010, 77 (03): : 238 - 249
  • [42] Endovascular repair of abdominal aortic aneurysms
    Bell, PRF
    [J]. VASCULAR MEDICINE, 2002, 7 (04) : 253 - 255
  • [43] A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysms - Discussion
    LoGerfo, F
    Faries, P
    Sicard, G
    Brewster, D
    Meyer, J
    Zwolak, R
    [J]. JOURNAL OF VASCULAR SURGERY, 2002, 35 (06) : 1128 - 1128
  • [44] Endovascular Stent graft repair of abdominal aortic aneurysms after liver transplantation
    Mekeel, KL
    Lee, WA
    Reed, AI
    Hemming, AW
    [J]. LIVER TRANSPLANTATION, 2005, 11 (08) : 993 - 997
  • [45] Safety and effectiveness of the TREO stent graft for the endovascular treatment of abdominal aortic aneurysms
    Eagleton, Matthew J.
    Stoner, Michael
    Henretta, John
    Dryjski, Maciej
    Panneton, Jean
    Tassiopoulos, Apostolos
    Mehta, Manish
    Pearce, Benjamin
    Sharafuddin, Mel J.
    [J]. JOURNAL OF VASCULAR SURGERY, 2021, 74 (01) : 114 - +
  • [46] Comparison of CT angiography and digital subtraction angiography for exclusion of vertebrobasilar aneurysms in patients with perimesencephalic type of subarachnoid hemorrhage
    Velthuis, BK
    Rinkel, GJ
    Ramos, LM
    Witkamp, TD
    VanLeeuwen, MS
    [J]. RADIOLOGY, 1997, 205 : 160 - 160
  • [47] INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY IN INTRACRANIAL ANEURYSMS
    BUTLER, P
    JHA, AN
    LYE, RH
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 816 - 816
  • [48] Endovascular exclusion of leaking thoracic aortic aneurysms
    Woody, JD
    Walot, I
    Donayre, CE
    Eugene, J
    Carey, JS
    White, RA
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 : 79 - 83
  • [49] INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY IN INTRACRANIAL ANEURYSMS
    BUTLER, P
    FREER, CEL
    JHA, AN
    LYE, RH
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (712): : 323 - 326
  • [50] Exclusion of accessory renal arteries during endovascular repair of abdominal aortic aneurysms - Discussion
    Hollier, L
    Rhee, RY
    Spence, R
    O'Donnell, S
    Criado, F
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 34 (05) : 884 - 884