UV light tolerance and reactivation potential of tetracycline-resistant bacteria from secondary effluents of a wastewater treatment plant

被引:1
|
作者
Jing-Jing Huang [1 ,2 ]
Jinying Xi [1 ]
Hong-Ying Hu [1 ]
Yi Li [3 ]
Sun-Qin Lu [3 ]
Fang Tang [1 ]
Yu-Chen Pang [1 ]
机构
[1] State Key Joint Laboratory of Environmental Simulation and Pollution Control,State Environmental Protection Key Laboratory of Microorganism Application and Risk Control,School of Environment,Tsinghua University
[2] China Power Engineering Consulting Group Co.LTD.
[3] College of Environmental Science and Engineering,Hohai University
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
X703 [废水的处理与利用]; X172 [环境微生物学];
学科分类号
071012 ; 0713 ; 083002 ;
摘要
Tetracycline-resistant bacteria(TRB) are of concern as emerging microbial contaminants in reclaimed water.To understand the effects of UV disinfection on TRB,both inactivation and reactivation profiles of TRB,as well as 16 tetracycline-resistant isolates from secondary effluent,were characterized in this study.The inactivation ratio of TRB was significantly lower(3.0-log) than that of heterotrophic bacteria(>4.0-log) in the secondary effluent.Additionally,the proportion of TRB significantly increased from 1.65%to 15.51%under20 mJ/cm2ultraviolet(UV) exposure.The inactivation rates of tetracycline-resistant isolates ranged from 0.57/s to 1.04/s,of which tetracycline-resistant Enterobacter-1 was the most tolerant to UV light.The reactivation of TRB,tetracycline-resistant isolated strains,as well as heterotrophic bacteria commonly occurred in the secondary effluent even after20 mJ/cm2UV exposure.The colony forming ability of TRB and heterotrophic bacteria reached 3.2-log and 3.0-log under 20 mJ/cm2UV exposure after 22 hr incubation.The final inactivation ratio of tetracycline-resistant Enterobacter-1 was 1.18-log under 20 mJ/cm2UV exposure after 22 hr incubation,which is similar to those of TRB(1.18-log) and heterotrophic bacteria(1.19-log).The increased proportion of TRB and the reactivation of tetracycline-resistant enterobacteria in reclaimed water could induce a microbial health risk during wastewater reuse.
引用
收藏
页码:146 / 153
页数:8
相关论文
共 50 条
  • [21] A novel system for the treatment of wastewater from a tomato processing plant with UV light
    Mahoney, Laura
    Younis, Bassam A.
    Simmons, Christopher W.
    WATER PRACTICE AND TECHNOLOGY, 2018, 13 (03) : 662 - 672
  • [22] A novel system for the treatment of wastewater from a tomato processing plant with UV light
    Mahoney L.
    Younis B.A.
    Simmons C.W.
    Younis, Bassam A. (bayounis@ucdavis.edu), 2018, IWA Publishing (13): : 662 - 672
  • [23] Effectiveness of wastewater treatment plant at the removal of nutrients, pathogenic bacteria, and antibiotic-resistant bacteria in wastewater from hospital source
    Grace O. Owojori
    Suraju A. Lateef
    Godson R. E. E. Ana
    Environmental Science and Pollution Research, 2024, 31 : 10785 - 10801
  • [24] Effectiveness of wastewater treatment plant at the removal of nutrients, pathogenic bacteria, and antibiotic-resistant bacteria in wastewater from hospital source
    Owojori, Grace O.
    Lateef, Suraju A.
    Ana, Godson R. E. E.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2024, 31 (07) : 10785 - 10801
  • [25] Inactivation and Regrowth of Antibiotic-resistant Bacteria by PAA Disinfection in the Secondary Effluent of a Municipal Wastewater Treatment Plant
    HUANG Jing Jing
    XI Jing Ying
    HU Hong Ying
    TANG Fang
    PANG Yu Chen
    Biomedical and Environmental Sciences, 2013, 26 (10) : 865 - 868
  • [26] Inactivation and Regrowth of Antibiotic-resistant Bacteria by PAA Disinfection in the Secondary Effluent of a Municipal Wastewater Treatment Plant
    Huang Jing Jing
    Xi Jing Ying
    Hu Hong Ying
    Tang Fang
    Pang Yu Chen
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2013, 26 (10) : 865 - 868
  • [27] Persistence of fecal indicator bacteria and associated genetic markers from wastewater treatment plant effluents in freshwater microcosms
    Chern, Eunice C.
    Wymer, Larry
    Brenner, Kristen
    Oshima, Kevin
    Haugland, Richard A.
    JOURNAL OF WATER AND HEALTH, 2022, 20 (01) : 205 - 215
  • [28] Plasmid sequence dataset of multidrug-resistant Enterobacterales isolated from hospital effluents and wastewater treatment plant
    Mutuku, Christopher
    Kutasy, Barbara
    Urban, Peter
    Melegh, Szilvia
    Herczeg, Robert
    Gazdag, Zoltan
    Virag, Eszter
    DATA IN BRIEF, 2022, 45
  • [29] Catalytic Ozonation of the Secondary Effluents from the Largest Chinese Petrochemical Wastewater Treatment Plant-A Stability Assessment
    Zhang, Siyu
    Wang, Hao
    Zhou, Yuexi
    Kamali, Mohammadreza
    He, Xuwen
    Khalaj, Mohammadreza
    Xia, Yu
    SUSTAINABILITY, 2022, 14 (04)
  • [30] Deciphering Multidrug-Resistant Plasmids in Disinfection Residual Bacteria from a Wastewater Treatment Plant
    Lin, Ze-Jun
    Zhou, Zhen-Chao
    Shuai, Xin-Yi
    Shan, Xiao-Yu
    Zhou, Jin-Yu
    Chen, Hong
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (15) : 6793 - 6803