Preliminary clinical outcome of the femur RetroButton combined with glaze allergenic cortical press-fit bolt fixation

被引:0
|
作者
蔡谞 [1 ]
机构
[1] Dept,Gen Hosp PLA
关键词
ACL; Preliminary clinical outcome of the femur RetroButton combined with glaze allergenic cortical press-fit bolt fixation;
D O I
暂无
中图分类号
R687.3 [骨骼手术];
学科分类号
摘要
Objective To investigate the preliminary clinical outcome of the femur RetroButton combined with glaze allogenic cortical press-fit bolt fixation in ACL reconstruction.Methods A series of 10 patients suffered from ACL ruptures underwent
引用
收藏
页码:108 / 109
页数:2
相关论文
共 21 条
  • [1] Progressive cancellous and cortical bone remodeling after press-fit cup fixation
    Mueller, Lutz A.
    Voelk, Michael
    Kress, Alexander
    Pitto, Rocco P.
    Schmidt, Rainer
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) : 213 - 220
  • [2] Intramedullary reaming for press-fit fixation of a humeral component removes cortical bone asymmetrically
    Lee, Michael
    Chebli, Caroline
    Mounce, Doug
    Bertelsen, Alexander
    Richardson, Michael
    Matsen, Frederick, III
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (01) : 150 - 155
  • [3] The initial fixation of the press-fit acetabular shell – clinical observation and experimental study
    K. Kaneko
    Yukio Inoue
    Yasushi Yanagihara
    Souichi Uta
    Atsuhiko Mogami
    Hideaki Iwase
    Archives of Orthopaedic and Trauma Surgery, 2000, 120 : 323 - 325
  • [4] The initial fixation of the press-fit acetabular shell - clinical observation and experimental study
    Kaneko, K
    Inoue, Y
    Yanagihara, Y
    Uta, S
    Mogami, A
    Iwase, H
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (5-6) : 323 - 325
  • [5] Cortical bone viscoelasticity and fixation strength of press-fit femoral stems: A finite element model
    Shultz, TR
    Blaha, JD
    Gruen, TA
    Norman, TL
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01): : 7 - 12
  • [6] Cortical bone viscoelasticity and fixation strength of press-fit femoral stems:: An in-vitro model
    Norman, TL
    Ackerman, ES
    Smith, TS
    Gruen, TA
    Yates, AJ
    Blaha, JD
    Kish, VL
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01): : 13 - 17
  • [7] Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement
    Christopher, Scott A.
    Kim, Stanley E.
    Roe, Simon
    Pozzi, Antonio
    VETERINARY JOURNAL, 2016, 214 : 7 - 9
  • [8] Clinical Results of Hamstring Autografts in Anterior Cruciate Ligament Reconstruction: A Comparison of Femoral Knot/Press-Fit Fixation and Interference Screw Fixation
    Ho, Wei-Pin
    Lee, Chian-Her
    Huang, Chang-Hung
    Chen, Chih-Hwa
    Chuang, Tai-Yuan
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (07): : 823 - 832
  • [9] The initial fixation of Press-fit acetabular socket. Its clinical observation and fundamental studyFixation initiale de prothèse cotylïdienne “Press-Fit”. Observation clinique et étude expérimentale
    K. Kaneko
    Y. Inoue
    A. Mogami
    H. Iwase
    European Journal of Orthopaedic Surgery & Traumatology, 2000, 10 (2) : 115 - 119
  • [10] Combined press-fit and extracortical fixation in patellar tendon anterior cruciate ligament reconstruction results in reliable graft fixation and early bone block incorporation
    Feichtinger, Xaver
    Muji, Edin
    Domej, Marija Ana
    Pauzenberger, Leo
    Baierl, Andreas
    Kocijan, Roland
    Loho, Gerald
    Brandl, Georg
    KNEE, 2023, 43 : 18 - 27