Tremor suppression strategy of the tremor suppression robot

被引:0
|
作者
赵杰 [1 ]
李军强 [1 ]
樊继壮 [1 ]
臧希喆 [1 ]
机构
[1] State Key Laboratory of Robotics and System,Harbin Institute of Technology
关键词
magnetorheological damper; fuzzy neural network; data fusion; tremor suppression strategy;
D O I
暂无
中图分类号
TP242 [机器人];
学科分类号
1111 ;
摘要
Based on the development of the performance of magnetorheological damper,the tremor suppression strategy that uses angle displacement sensor and force sensor to sense the information of the tremor and uses the fuzzy neural network as the control algorithm is presented. The information of the maximum tremor torque can be achieved exactly by means fusing the data of displacement sensor and the data of force sensor. Due to the slow change of the maximum tremor torque,the fuzzy neural network with single input variable and single output variable is adopted as the control algorithm,and the mathematic model of fuzzy neural network is worked out. The elbow tremor suppression model is established to provide tremor information for fuzzy neural network training and tremor suppression strategy simulation,then the off-line fuzzy neural network training is finished with the selected training data set,and the tremor suppression strategy is simulated. Simulation results show that the tremor suppression strategy has presented is effectually for the tremor suppression.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [31] Dynamically responsive intervention for tremor suppression
    Manto, M
    Topping, M
    Soede, M
    Sanchez-Lacuesta, J
    Harwin, W
    Pons, J
    Williams, J
    Skaarup, S
    Normie, L
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (03): : 120 - 132
  • [32] A wearable tremor-suppression orthosis
    Kotovsky, J
    Rosen, MJ
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1998, 35 (04): : 373 - 387
  • [33] Volitional Suppression of Parkinsonian Resting Tremor
    Blakemore, Rebekah L.
    MacAskill, Michael R.
    Myall, Daniel J.
    Anderson, Tim J.
    MOVEMENT DISORDERS CLINICAL PRACTICE, 2019, 6 (06): : 470 - 478
  • [34] Tremor suppression through impedance control
    Pledgie, S
    Barner, KE
    Agrawal, SK
    Rahman, T
    IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, 2000, 8 (01): : 53 - 59
  • [35] Optimal digital filtering for tremor suppression
    Gonzalez, JG
    Heredia, EA
    Rahman, T
    Barner, KE
    Arce, GR
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (05) : 664 - 673
  • [36] The anatomic specificity of rest tremor suppression
    Davis, TL
    Charles, PD
    Kao, C
    Fang, JY
    Fenichel, GM
    Konrad, PE
    MOVEMENT DISORDERS, 2004, 19 : S319 - S319
  • [37] Estimation of Instantaneous Tremor Parameters for FES-Based Tremor Suppression
    Gallego, J. A.
    Rocon, E.
    Pons, J. L.
    2010 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2010, : 2922 - 2927
  • [38] Voluntary suppression of Parkinson's tremor
    Blakemore, R.
    MacAskill, M.
    Myall, D.
    Anderson, T.
    MOVEMENT DISORDERS, 2018, 33 : S548 - S548
  • [39] A Review on Wearable Technologies for Tremor Suppression
    Lora-Millan, Julio S.
    Delgado-Oleas, Gabriel
    Benito-Leon, Julian
    Rocon, Eduardo
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [40] Essential tremor suppression using a novel anti-tremor orthosis
    Mugge, W.
    Elstgeest, L.
    van Ginkel, M.
    Pol, L.
    de Lange, I. J.
    Pambakian, N.
    Souza, A.
    Helmich, R.
    Kamphuis, D.
    MOVEMENT DISORDERS, 2023, 38 : S434 - S434