摘要
A Fricke-PVA-xylenol orange (FPX) hydrogel dosimeter, in good transparency, was prepared by physical crosslinking for three-dimensional dose measurements. The process of mixing the chemical dosimeter with the PVA solution was carried out at room temperature, which reduced the influence of auto-oxidation rate. Gradation in color was obviously observed with different distance from the radiation source after 6 MeV electron beam irradiation for radiotherapy. The effects of irradiation dose and three components of the FPX gel dosimeter, i.e. ferrous ions, xylenol orange (XO) and sulphuric acid on sensitivity and stability of dose response were investigated by UV-vis spectropho-tometric measurement. The dose response of the FPX gel dosimeter was linear in the range 0.0 Gy. The orthogonal test was employed to find the optimal composition of the gel dosimeter with a sensitivity of about 0.095 cm-1·Gy-1. It was found that XO concentration greatly affected the sensitivity of dose response and lower concentrations of the ferrous ion and XO gave higher sensitivity within the range 0.0 Gy.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 50 条
  • [21] End-to-end quality assurance for stereotactic radiotherapy with Fricke-Xylenol orange-Gelatin gel dosimeter and dual-wavelength cone-beam optical CT readout
    Rousseau, Alice
    Stien, Christel
    Gouriou, Jean
    Bordy, Jean-Marc
    Boissonnat, Guillaume
    Chabert, Isabelle
    Dufreneix, Stephane
    Blideanu, Valentin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 113
  • [22] How Xylenol Orange and Ferrous Ammonium Sulphate Influence the Dosimetric Properties of PVA-GTA Fricke Gel Dosimeters: A Spectrophotometric Study
    Scotti, Martina
    Arosio, Paolo
    Brambilla, Elisa
    Gallo, Salvatore
    Lenardi, Cristina
    Locarno, Silvia
    Orsini, Francesco
    Pignoli, Emanuele
    Pedicone, Luca
    Veronese, Ivan
    GELS, 2022, 8 (04)
  • [23] Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters
    Gambarini, G.
    Veronese, I.
    Bettinelli, L.
    Felisi, M.
    Gargano, M.
    Ludwig, N.
    Lenardi, C.
    Carrara, M.
    Collura, G.
    Gallo, S.
    Longo, A.
    Marrale, M.
    Tranchina, L.
    d'Errico, F.
    RADIATION MEASUREMENTS, 2017, 106 : 622 - 627
  • [24] Study of light transmittance from layers of Fricke-xylenol-orange-gel dosimeters
    Gambarini, G
    Birattari, C
    Mariani, M
    Marchesini, R
    Pirola, L
    Prestini, P
    Sella, M
    Tomatis, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 321 - 324
  • [25] Characterization of Radiochromic Hydrogel Dosimeter-Ferrous Xylenol Orange Enhanced to Have a Higher Melting Point
    da Silveira, Matheus Antonio
    Pavoni, Juliana Fernandes
    Jordan, Kevin
    Baffa, Oswaldo
    BRAZILIAN JOURNAL OF PHYSICS, 2024, 54 (05)
  • [26] Fricke-Xylenol orange-Gelatin gel characterization with dual wavelength cone-beam optical CT scanner for applications in stereotactic and dynamic radiotherapy
    Rousseau, Alice
    Stien, Christel
    Bordy, Jean-Marc
    Blideanu, Valentin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 97 : 1 - 12
  • [27] Effect of D-(+)-Glucose on the Stability of Polyvinyl Alcohol Fricke Hydrogel Three-Dimensional Dosimeter for Radiotherapy
    Yang, Yuejiao
    Chen, Jie
    Yang, Liming
    Chen, Bin
    Sheng, Zhenmei
    Luo, Wenyun
    Sui, Guoping
    Lu, Xun
    Chen, Jianxin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2016, 48 (03) : 608 - 612
  • [28] Does the gelation temperature or the sulfuric acid concentration influence the dosimetric properties of radiochromic PVA-GTA Xylenol Orange Fricke gels?
    Gallo, Salvatore
    Gambarini, Grazia
    Veronese, Ivan
    Argentiere, Simona
    Gargano, Marco
    Ianni, Luca
    Lenardi, Cristina
    Ludwig, Nicola
    Pignoli, Emanuele
    D'Errico, Francesco
    RADIATION PHYSICS AND CHEMISTRY, 2019, 160 : 35 - 40
  • [29] Synthesis and Characterization of PVP/PVA Hydrogels Using E-beam Irradiation
    Hwang, In-Seol
    Lee, Mi-Hwa
    Lim, Jung-Hyurk
    Kim, Kyung-Min
    7TH IEEE INTERNATIONAL NANOELECTRONICS CONFERENCE (INEC) 2016, 2016,
  • [30] E-beam resist outgassing for study of correlation between resist sensitivity and e-beam optic contamination
    Lee, Sung-Il
    Jeong, Yun Song
    Park, Cheol Hong
    Kim, Hee Bom
    Shin, Inkyun
    Jeon, Chan-Uk
    PHOTOMASK AND NEXT-GENERATION LITHOGRAPHY MASK TECHNOLOGY XX, 2013, 8701