Standard-sample bracketing calibration method combined with Mg as an internal standard for silicon isotopic compositions using multi-collector inductively coupled plasma mass spectrometry

被引:0
|
作者
Honglin Yuan [1 ]
Cheng Cheng [1 ]
Kaiyun Chen [1 ]
Zhian Bao [1 ]
机构
[1] State Key Laboratory of Continental Dynamics, Department of Geology, Northwest University, Collaborative Innovation Center of Continental Tectonics
基金
中国国家自然科学基金;
关键词
Si isotope; Mg internal standard; MC-ICPMS; Rock samples; High resolution;
D O I
暂无
中图分类号
P597 [同位素地质学与地质年代学];
学科分类号
070902 ;
摘要
Silicon isotope analysis traditionally uses a standard-sample bracketing(SSB) method that relies upon greater instrument stability than can be consistently expected. The following proposed method reduces the level of instrumental stability required for the analysis process and provides a valid solution for high-precision and accurate studies of Si isotopic compositions. Rock samples were dissolved by using alkali fusion and acidification.Silicon isotopes were purified with an ion exchange resin.Interfering peaks for isotopes were separated by using a Nu Plasma 1700 multi-collector inductively coupled plasma mass spectrometry(MS) system in high-resolution mode(M/DM [ 8000 RP). Two magnesium isotopes(Mg andMg) and three silicon isotopes(Si,Si, andSi) were analyzed in the same data collection cycle. Mg isotopes were used as an internal standard to calibrate the mass discrimination effects in MS analysis of Si isotopes in combination with the SSB method in order to reduce the effects of MS interference and instrumental mass discrimination on the accuracy of measurements. The conventional SSB method without the Mg internal standard and the proposed SSB method with Mg calibration delivered consistent results within two standard deviations.When Mg was used as an internal standard for calibration,the analysis precision was better than 0.05 % amu.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 50 条
  • [21] Accurate lithium isotopic analysis of twenty geological reference materials by multi-collector inductively coupled plasma mass spectrometry
    Li, Xiaoqiang
    Han, Guilin
    Zhang, Qian
    Qu, Rui
    Miao, Zhuang
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 188
  • [22] Determination of magnesium isotopic ratios of biological reference materials via multi-collector inductively coupled plasma mass spectrometry
    Goff, Samuel Le
    Albalat, Emmanuelle
    Dosseto, Anthony
    Godin, Jean-Philippe
    Balter, Vincent
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (10)
  • [23] Zirconium isotopic composition of zircon reference materials by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Xie, Jin-Cheng
    Zhu, Di-Cheng
    Wang, Qing
    Zhang, Liang-Liang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2023, 484
  • [24] Sm-Nd isotopic analysis of mixed standard solutions by multi-collector inductively coupled plasma mass spectrometry: evaluations on isobaric interference correction of Nd isotopic composition and external calibration of Sm/Nd ratio
    Ryu J.-S.
    Choi M.S.
    Jeong Y.-J.
    Cheong C.-S.
    Journal of Analytical Science and Technology, 4 (1)
  • [25] Polynomial mass bias functions for the internal standardization of isotope ratio measurements by multi-collector inductively coupled plasma mass spectrometry
    Doherty, William
    Gregoire, D. Conrad
    Bertrand, Nicole
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (03) : 407 - 414
  • [26] Common analyte internal standardization as a tool for correction for mass discrimination in multi-collector inductively coupled plasma-mass spectrometry
    Devulder, Veerle
    Lobo, Lara
    Van Hoecke, Karen
    Degryse, Patrick
    Vanhaecke, Frank
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 89 : 20 - 29
  • [27] Fast and precise boron isotopic analysis of carbonates and seawater using Nu Plasma II multi-collector inductively coupled plasma mass spectrometry and a simple sample introduction system
    Chen, Xin-Yang
    Teng, Fang-Zhen
    Catling, David C.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (14) : 1169 - 1178
  • [28] Fit for purpose validated method for the determination of the strontium isotopic signature in mineral water samples by multi-collector inductively coupled plasma mass spectrometry
    Brach-Papa, Christophe
    Van Bocxstaele, Marleen
    Ponzevera, Emmanuel
    Quetel, Christophe R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (03) : 229 - 234
  • [29] ACTIVITY RATIO OF URANIUM IN FUKUSHIMA SOIL SAMPLES USING MULTI-COLLECTOR INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
    Murugan, Rajamanickam
    Sahoo, Sarata Kumar
    Sorimachi, Atsuyuki
    Omori, Yasutaka
    Aono, Tatsuo
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (13-15) : 934 - 937
  • [30] Modified ion exchange separation for tungsten isotopic measurements from kimberlite samples using multi-collector inductively coupled plasma mass spectrometry
    Sahoo, YV
    Nakai, S
    Ali, A
    ANALYST, 2006, 131 (03) : 434 - 439