Measurement Error of Refractive Index for Spectacle Lens

被引:0
|
作者
叶佳意 [1 ,2 ]
蒋伟忠 [1 ,2 ]
唐玲玲 [1 ]
机构
[1] Research Institute ,Donghua University
[2] College of Materials Science and Engineering,Donghua University
关键词
spectacles lens; refractive index; measurement error; V prism refractometer;
D O I
10.19884/j.1672-5220.2017.04.023
中图分类号
TS959.6 [眼镜及其制造];
学科分类号
摘要
As an important optical constant of optical properties for spectacle lens,the refractive index measurement is studied using V prism refractometer. In the experiment,according to various factors inducing measurement error,the experimental results are analyzed,which include right angle deviation,contact liquid,curvature,and focusing accuracy. The study results show that focusing accuracy is the most important factor of influence for measurement,consists of contact liquid wettability,sample shape,and effective width of light transmission. In addition,the refractive index measurement is less affected by angle deviation of sample and the refractive index deviation of contact liquid. On the basis of the experimental data analysis,it is possible to relax the deviation of right angle of the sample to 1’ or 2’.
引用
收藏
页码:613 / 616
页数:4
相关论文
共 50 条
  • [21] Prevalence of Refractive Error and Spectacle Coverage in Zoba Ma'ekel Eritrea: A Rapid Assessment of Refractive Error
    Chan, Ving Fai
    Mebrahtu, Goitom
    Ramson, Prasidh
    Wepo, Mary
    Naidoo, Kovin S.
    OPHTHALMIC EPIDEMIOLOGY, 2013, 20 (03) : 131 - 137
  • [22] Prevalence of refractive error, presbyopia and spectacle coverage in Kahama District, Tanzania: a rapid assessment of refractive error
    Mashayo, Eden R.
    Chan, Ving Fai
    Ramson, Prasidh
    Chinanayi, Farai
    Naidoo, Kovin S.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2015, 98 (01) : 58 - 64
  • [23] Effect of refractive index measurement error on immersion grating spectral lines
    Qian, Tang
    Min, Zhang Chun
    Chang, Zhao Bao
    FIFTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATION, 2019, 11023
  • [24] Crystalline Lens Power and Refractive Error
    Iribarren, Rafael
    Morgan, Ian G.
    Nangia, Vinay
    Jonas, Jost B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (02) : 543 - 550
  • [25] Refractive error, through the lens of the patient
    Foreman, Joshua
    Dirani, Mohamed
    Taylor, Hugh
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (07): : 673 - 674
  • [26] The measurement of refractive index profile and aberration of radial gradient index lens by using imaging method
    Sun, XH
    Ma, H
    Ming, H
    Zheng, ZQ
    Yang, JW
    Xie, JP
    OPTICS AND LASER TECHNOLOGY, 2004, 36 (02): : 163 - 166
  • [27] The Refractive Error and Vision Impairment Estimation with Spectacle Data Study
    Moore, Michael
    Loughman, James
    Butler, John S.
    Ohlendorf, Arne
    Wahl, Siegfried
    Flitcroft, Daniel I.
    OPHTHALMOLOGY SCIENCE, 2022, 2 (01):
  • [28] VARIFOCAL SPECTACLE LENS SURFACE POWER MEASUREMENT
    FOWLER, CW
    SULLIVAN, CM
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1988, 8 (02) : 231 - 233
  • [29] Remote measurement of spherocylindrical spectacle lens prescriptions
    Guan, Yuanxin
    Miller, Joseph M. M.
    Harvey, Erin M. M.
    Schwiegerling, Jim
    OPTICAL ENGINEERING, 2022, 61 (12)
  • [30] Deflectometric measurement of mechanical spectacle lens deformation
    Peral, A
    Alonso, J
    Sanz, JC
    Bernabeu, E
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2000, 20 (06) : 473 - 479