Performance assessment of water mist applied in gas burning suppression in underground coal mine

被引:3
|
作者
余明高 [1 ]
郑立刚 [1 ]
刘志超 [2 ]
潘荣锟 [1 ]
贾海林 [1 ]
袁俊 [3 ]
机构
[1] School of Safety Science and Engineering,Henan Polytechnic University,Jiaozuo 454000,China
[2] School of Mechanical Science and Engineering,Henan Polytechnic University,Jiaozuo 454000,China
[3] Huarun Thermal Power Ltd.,Tangshan 301900,China
关键词
gas burning; water mist; coal mine; fire suppression; performance assessment;
D O I
暂无
中图分类号
TD753.7 [];
学科分类号
081903 ;
摘要
The main objective of the present study was introduced water mist suppressiontechnology to prevent and control gas burning which occurred during drilling at Wu20160working-face in No.10 coal mine of Pingdingshan Ltd..Based on the self-developed ex-periment platform,a series of fire suppression tests to evaluate the performance of a watermist system were conducted.The detailed measurements of the spray characteristics,i.e.,the Sauter Mean Diameter(SMD),the velocity and spray angle which are the main pa-rameters considered in the Study,were obtained by using LS-2000 Sizer.The amount ofwater consumed and the water flux density distribution over the cross section downstreamthe nozzle exit were measured by cup collector method.The operating pressure of thewater mist nozzle is set to 0.5 MPa,the droplet SMD of 104 pm,the water flux density dis-tribution from 0.71 to 8.47 L/(m2.min),the average velocity of 2.14 m/s.The experimentalresults show that the averaged time required for extinguishment is 3.14 s,and the corre-sponding amount of water used during fire test is about 0.11 kg.The gas fire suppressionsystem reduces the temperature in combustion chamber of the experimental apparatusbelow the ignition point of the gas,which can effectively avoid the occurrence of the gasfire in coal mine.
引用
收藏
页码:48 / 52
页数:5
相关论文
共 50 条
  • [11] Applied water mist fire suppression system in historic buildings
    Lee M.-J.
    Wen I.-J.
    Chung K.-C.
    Journal of Applied Fire Science, 2010, 20 (01): : 55 - 69
  • [12] The influence of forced ventilation airflow on water spray for dust suppression on heading face in underground coal mine
    Wang, Hetang
    Wang, Chen
    Wang, Deming
    POWDER TECHNOLOGY, 2017, 320 : 498 - 510
  • [13] Effect of flue gas desulfurization (FGD) by-product on water quality at an underground coal mine
    Lamminen, M
    Wood, J
    Walker, H
    Chin, YP
    He, YT
    Traina, SJ
    JOURNAL OF ENVIRONMENTAL QUALITY, 2001, 30 (04) : 1371 - 1381
  • [14] Key Technologies and Applications of Gas Drainage in Underground Coal Mine
    Zhou, Bo
    Xue, Sheng
    Cheng, Jiansheng
    Li, Wen Quan
    Xiao, Jiaping
    3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2018, 113
  • [15] Evaluation of underground coal gas drainage performance: Mine site measurements and parametric sensitivity analysis
    Liu, Peng
    Fan, Jinyang
    Jiang, Deyi
    Li, Jiajun
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 148 : 711 - 723
  • [16] Risk Assessment of Water Inrush in an Underground Coal Mine Based on GIS and Fuzzy Set Theory
    Yang, Binbin
    Sui, Wanghua
    Duan, Lihong
    MINE WATER AND THE ENVIRONMENT, 2017, 36 (04) : 617 - 627
  • [17] Qualitative Assessment of Strata Control in an Indian Underground Coal Mine
    Ala C.K.
    Tripathy D.P.
    Journal of The Institution of Engineers (India): Series D, 2016, 97 (1) : 99 - 104
  • [18] Study on the Interaction Mechanism between Residual Coal and Mine Water in Goaf of Coal Mine Underground Reservoir
    Jiang, Binbin
    Zhao, Ze
    Liu, Deqian
    Cao, Zhiguo
    Tang, Jiawei
    Wu, Min
    Zhang, Haiqin
    Li, Peng
    Liang, Dingcheng
    SUSTAINABILITY, 2023, 15 (20)
  • [19] Water quality changes of a closed underground coal mine in Korea
    Cheong, Young Wook
    Yim, Gil-Jae
    Ji, Sang Woo
    Kang, Sang Soo
    Skousen, Jeffery
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2012, 184 (01) : 503 - 513
  • [20] Water quality changes of a closed underground coal mine in Korea
    Young Wook Cheong
    Gil-Jae Yim
    Sang Woo Ji
    Sang Soo Kang
    Jeffery Skousen