Contrast-enhanced ultrasonography in the evaluation of incidental focal liver lesions: A cost-effectiveness analysis

被引:4
|
作者
Miriama Smajerova [1 ,2 ]
Hana Petrasova [1 ,2 ]
Jirina Little [1 ,2 ]
Petra Ovesna [3 ]
Tomas Andrasina [1 ,2 ]
Vlastimil Valek [1 ,2 ]
Eva Nemcova [1 ,2 ]
Barbora Miklosova [1 ,2 ]
机构
[1] Department of Radiology,University Hospital Brno
[2] Faculty of Medicine,Masaryk University
[3] Institute of Biostatistics and Analyses,Masaryk University
关键词
Contrast-enhanced ultrasonography; Focal liver lesion; Computed tomography; Magnetic resonance imaging; Economic analysis;
D O I
暂无
中图分类号
R575 [肝及胆疾病]; R445 [影像诊断学];
学科分类号
1002 ; 100201 ; 100207 ;
摘要
AIM To determine whether contrast-enhanced ultrasonography(CEUS) as the first-line method is more costeffective in evaluating incidentally discovered focal liver lesions(FLLs) than is computed tomography(CT) and magnetic resonance imaging(MRI). METHODS Between 2010 and 2015, our prospective study enrolled 459 patients with incidentally found FLLs. The biological nature of FLLs was assessed by CEUS in all patients. CT or MRI examinations were added in unclear cases. The sensitivity and specificity of CEUS were calculated. The total costs of CEUS examinations and of the added examinations performed in inconclusive cases were calculated. Afterwards, the theoretical expenses for evaluating incidentally discovered FLLs using CT or MRI as the first-line method were calculated. The resultswere compared. RESULTS The total cost of the diagnostic process using CEUS for all enrolled patients with FLLs was 75884 USD. When the expenses for additional CT and MRI examinations performed in inconclusive cases were added, the total cost was 90540 US dollar(USD). If all patients had been examined by CT or MR as the first-line method, the costs would have been 78897 USD or 384235 USD, respectively. The difference between the cost of CT and CEUS was 3013 USD(4%) and that between MRI and CEUS was 308352 USD(406.3%). We correctly described 97.06% of benign or malignant lesions, with 96.99% sensitivity and 97.09% specificity. Positive predictive value was 94.16% and negative predictive value was 98.52%. In cases with 4 and more lesions, malignancy is significantly more frequent and inconclusive findings significantly less frequent(P < 0.001).CONCLUSION While the costs of CEUS and CT in evaluating FLLs are comparable, CEUS examination is far more costeffective in comparison to MRI.
引用
收藏
页码:8605 / 8614
页数:10
相关论文
共 50 条
  • [31] Characterization of focal liver lesions with contrast-enhanced ultrasound
    Nicolau, C
    Catalá, V
    Brú, C
    EUROPEAN RADIOLOGY, 2003, 13 (Suppl 3) : N70 - N78
  • [32] Clinical value of contrast-enhanced ultrasonography in the characterization of focal liver lesions:a prospective multicenter trial
    Wen-Ping Wang
    Department of Ultrasound
    Department of Diagnostic Ultrasound
    Department of Electrodiagnosis
    Hepatobiliary&PancreaticDiseasesInternational, 2009, 8 (04) : 370 - 376
  • [33] Comparative diagnostic value of computed tomography and contrast-enhanced ultrasonography in diagnosis of focal liver lesions
    Zviniene, Kristina
    Zaboriene, Inga
    Basevicius, Algidas
    Pundzius, Juozas
    MEDICINA-LITHUANIA, 2009, 45 (10): : 751 - 763
  • [34] Computer-aided diagnosis for the classification of focal liver lesions by use of contrast-enhanced ultrasonography
    Shiraishi, Junji
    Sugimoto, Katsutoshi
    Moriyasu, Fuminori
    Kamiyama, Naohisa
    Doi, Kunio
    MEDICAL PHYSICS, 2008, 35 (05) : 1734 - 1746
  • [35] Clinical value of contrast-enhanced ultrasonography in the characterization of focal liver lesions: a prospective multicenter trial
    Wang, Wen-Ping
    Wu, Ying
    Luo, Yan
    Li, Rui
    Zhou, Xiao-Dong
    Zhang, Jun
    Qian, Chao-Wen
    Tan, Xu-Yan
    Xu, Qing-Hua
    Wang, Yan
    Yuan, Jian-Jun
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2009, 8 (04) : 370 - 376
  • [36] Hypoechoic focal liver lesions:: Characterization with contrast enhanced ultrasonography
    D'Onofrio, M
    Rozzanigo, U
    Masinielli, BM
    Caffarri, S
    Zogno, A
    Malagò, R
    Procacci, C
    JOURNAL OF CLINICAL ULTRASOUND, 2005, 33 (04) : 164 - 172
  • [37] Contrast-Enhanced Ultrasound for the Evaluation of Focal Liver Lesions - a Multicenter Trial in Romania
    Sandulescu, Larisa
    Badea, Radu
    Sporea, Ioan
    Popescu, Alina
    Socaciu, Mihai
    Saftoiu, Adrian
    MEDICAL ULTRASONOGRAPHY, 2011, 13 (03) : 258 - 259
  • [38] CHARACTERIZATION OF FOCAL LIVER LESIONS BY CONTRAST-ENHANCED ULTRASOUND IN THE NETHERLANDS: AN ECONOMIC EVALUATION
    Zaim, R.
    Taimr, P.
    De Knegt, R.
    Redekop, W.
    Uyl-de Groot, C.
    VALUE IN HEALTH, 2011, 14 (07) : A248 - A248
  • [39] Clinical value of contrast-enhanced ultrasonography in focal hypoechogenic lesions of thyroid
    Liang, Songnian
    Gao, Ningning
    Bian, Donglin
    Zhai, Qixi
    Yang, Puxu
    Huang, Kun
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (04) : 2077 - 2082
  • [40] Clinical value of contrast-enhanced ultrasonography in focal hypoechogenic lesions of thyroid
    Songnian Liang
    Ningning Gao
    Donglin Bian
    Qixi Zhai
    Puxu Yang
    Kun Huang
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 2077 - 2082