Experimentally-determined characteristics of radiant systems for office buildings

被引:0
|
作者
Hongyuan Jia
Xiufeng Pang
Philip Haves
侯恩哲
机构
关键词
Radiant systems; Stratification; Operative temperature; Variation in comfort; FLEXLAB;
D O I
暂无
中图分类号
TU83 [空气调节、采暖、通风及其设备];
学科分类号
081404 ;
摘要
Radiant heating and cooling systems have significant energy-saving potential and are gaining popularity in commercial buildings. The main aim of the experimental study reported here was to characterize the behavior of radiant cooling systems in a typical office environment,including the effect of ceiling fans on stratification,the variation in comfort conditions from perimeter to core,control on operative temperature vs. air temperature and the effect of carpet on cooling capacity. The goal was to limit both the first cost and the perceived risk associated with such systems. Two types of radiant systems,the radiant ceiling panel( RCP) system and the radiant slab( RS) system,were investigated. The experiments were carried out in one of the test cells that constitute the FLEXLAB test facility at the Law rence Berkeley National Laboratory in March and April 2016. In total,tentest cases( five for RCP and five for RS) were performed,covering a range of operational conditions. In cooling mode,the air temperature stratification is relatively small in the RCP,with a maximum value of 1. 6 K. The observed stratification effect was significantly greater in the RS,tw ice as much as that in the RCP.The maximum increase in dry bulb temperature in the perimeter zone due to solar radiation was 1. 2 K for RCP and 0. 9 K for RS-too small to have a significant impact on thermal comfort. The use of ceiling fans was able to reduce any excess stratification and provide better indoor comfort,if required. The use of thin carpet requires a 1 K low er supply chilled water temperature to compensate for the added thermal resistance,somew hat reducing the opportunities for water-side free cooling and increasing the risk of condensation. In both systems,the difference betw een the room operative temperature and the room air temperature is small when the cooling loads are met by the radiant systems. This makes it possible to use the air temperature to control the radiant systems in lieu of the operative temperature,reducing both first cost and maintenance costs.
引用
收藏
页码:118 / 118
页数:1
相关论文
共 50 条
  • [41] Experimentally Determined Evaporation Rates in Pervious Concrete Systems
    Syrrakou, Christina
    Pinder, George F.
    JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2014, 140 (01)
  • [42] Sensitivity of design parameters on energy, system and comfort performances for radiant cooled office buildings in the tropics
    Talami, Riccardo
    Jakubiec, J. Alstan
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 1786 - 1793
  • [43] Structural refinement of membrane proteins on the basis of experimentally-determined solvent accessibility from spin-label electron paramagnetic resonance spectroscopy
    Sompornpisut, Pornthep
    Perozo, Eduardo
    Roux, Benoit
    BIOPHYSICAL JOURNAL, 2007, : 318A - 319A
  • [44] Characteristics of bioaerosol profile in office buildings in Hong Kong
    Law, AKY
    Chau, CK
    Chan, GYS
    BUILDING AND ENVIRONMENT, 2001, 36 (04) : 527 - 541
  • [45] Principles and characteristics of biological assemblies in experimentally determined protein structures
    Xu, Qifang
    Dunbrack, Roland L., Jr.
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2019, 55 : 34 - 49
  • [46] Sensitivity analysis of experimentally determined grounding grid impulse characteristics
    Stojkovic, Z
    Savic, MS
    Nahman, JM
    Salamon, D
    Bukorovic, B
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) : 1136 - 1142
  • [47] Comparison of experimentally and theoretically determined radiation characteristics of photosynthetic microorganisms
    Kandilian, Razmig
    Pruvost, Jeremy
    Artu, Arnaud
    Lemasson, Camille
    Legrand, Jack
    Pilon, Laurent
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2016, 175 : 30 - 45
  • [48] An experimentally-determined general formalism for evaporation and isotope fractionation of Cu and Zn from silicate melts between 1300 and 1500 °C and 1 bar
    Sossi, Paolo A.
    Moynier, Frederic
    Treilles, Robin
    Mokhtari, Marwane
    Wang, Xiang
    Siebert, Julien
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2020, 288 : 316 - 340
  • [49] Analysis of Integrated Radiant Slab Heating and Cooling Systems for Residential Buildings
    Park, Benjamin
    Krarti, Moncef
    JOURNAL OF ARCHITECTURAL ENGINEERING, 2016, 22 (01)
  • [50] Occupants' operation of lighting and shading systems in office buildings
    Department of Building Physics and Building Ecology, Vienna University of Technology, Vienna, Austria
    Journal of Building Performance Simulation, 2008, 1 (01) : 57 - 65