Experimentally-determined characteristics of radiant systems for office buildings

被引:0
|
作者
Hongyuan Jia
Xiufeng Pang
Philip Haves
侯恩哲
机构
关键词
Radiant systems; Stratification; Operative temperature; Variation in comfort; FLEXLAB;
D O I
暂无
中图分类号
TU83 [空气调节、采暖、通风及其设备];
学科分类号
081404 ;
摘要
Radiant heating and cooling systems have significant energy-saving potential and are gaining popularity in commercial buildings. The main aim of the experimental study reported here was to characterize the behavior of radiant cooling systems in a typical office environment,including the effect of ceiling fans on stratification,the variation in comfort conditions from perimeter to core,control on operative temperature vs. air temperature and the effect of carpet on cooling capacity. The goal was to limit both the first cost and the perceived risk associated with such systems. Two types of radiant systems,the radiant ceiling panel( RCP) system and the radiant slab( RS) system,were investigated. The experiments were carried out in one of the test cells that constitute the FLEXLAB test facility at the Law rence Berkeley National Laboratory in March and April 2016. In total,tentest cases( five for RCP and five for RS) were performed,covering a range of operational conditions. In cooling mode,the air temperature stratification is relatively small in the RCP,with a maximum value of 1. 6 K. The observed stratification effect was significantly greater in the RS,tw ice as much as that in the RCP.The maximum increase in dry bulb temperature in the perimeter zone due to solar radiation was 1. 2 K for RCP and 0. 9 K for RS-too small to have a significant impact on thermal comfort. The use of ceiling fans was able to reduce any excess stratification and provide better indoor comfort,if required. The use of thin carpet requires a 1 K low er supply chilled water temperature to compensate for the added thermal resistance,somew hat reducing the opportunities for water-side free cooling and increasing the risk of condensation. In both systems,the difference betw een the room operative temperature and the room air temperature is small when the cooling loads are met by the radiant systems. This makes it possible to use the air temperature to control the radiant systems in lieu of the operative temperature,reducing both first cost and maintenance costs.
引用
收藏
页码:118 / 118
页数:1
相关论文
共 50 条
  • [1] Experimentally-determined characteristics of radiant systems for office buildings
    Jia, Hongyuan
    Pang, Xiufeng
    Haves, Philip
    APPLIED ENERGY, 2018, 221 : 41 - 54
  • [2] Activated carbon efficient atomistic model construction that depicts experimentally-determined characteristics
    Huang, Yang
    Cannon, Fred S.
    Watson, Justin K.
    Reznik, B.
    Mathews, Jonathan P.
    CARBON, 2015, 83 : 1 - 14
  • [3] EXPERIMENTALLY-DETERMINED VS THEORETICAL VALUES OF ROVING STRENGTH
    SWIECH, T
    TEXTILE RESEARCH JOURNAL, 1978, 48 (11) : 637 - 646
  • [4] DEPENDENCE OF THE DEFORMATION ENERGY OF BASIC NUCLEAR STATE ON THE EXPERIMENTALLY-DETERMINED CHARACTERISTICS OF ROTATIONAL BANDS
    BEGZHANOV, RB
    BELENKII, VM
    VOLMYANSKII, EI
    DUBRO, VG
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1978, 42 (12): : 2632 - 2633
  • [5] PHYSICAL CONDITION OF FELSIC MAGMA CONSTRAINED BY EXPERIMENTALLY-DETERMINED PHASE-RELATIONS
    SEKINE, T
    ARAMAKI, S
    GEOCHEMICAL JOURNAL, 1992, 26 (05) : 279 - 290
  • [6] Using an experimentally-determined model of the evolution of pore structure for the calcination of cycled limestones
    Dai, Peng
    Gonzalez, Belen
    Dennis, John S.
    CHEMICAL ENGINEERING JOURNAL, 2016, 304 : 175 - 185
  • [7] Experimentally-determined dose calibrator settings for a yttrium-90 radioimmunotherapy agent.
    Cessna, JT
    Karam, LR
    Coursey, BM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U85 - U85
  • [8] Using an experimentally-determined model of the evolution of pore structure for the gasification of chars by CO2
    Dai, Peng
    Dennis, John S.
    Scott, Stuart A.
    FUEL, 2016, 171 : 29 - 43
  • [9] Correlations Between Experimentally-Determined Melting Temperatures and GC-Content for Short DNA Strands
    Tulpan, Dan
    Montemanni, Roberto
    Smith, Derek H.
    CURRENT BIOINFORMATICS, 2017, 12 (04) : 296 - 302
  • [10] Green Scheduling for Radiant Systems in Buildings
    Nghiem, Truong X.
    Behl, Madhur
    Pappas, George J.
    Mangharam, Rahul
    2012 IEEE 51ST ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), 2012, : 7577 - 7582