Experimental Study on Measurement of Flame Temperature Distribution Using the Two-Color Method

被引:0
|
作者
Fan Jiang Shi Liu Gang Lu Yong Yan Haigang Wang Yanmin Song Renxiong Ma Zhonggang PanInstitute of Engineering Thermophysics
机构
关键词
flame; temperature distribution; two-color method;
D O I
暂无
中图分类号
TK31 [量测技术及仪表];
学科分类号
080702 ;
摘要
A novel optical instrumentation system for flame characterization was developed and tested. The two-color system is capable of performing on-line measurement of flame and temperature distribution, providing temporal and spatial characterization of the combustion process. In addition, the system has the advantage of being non-intrusive. The on-line measurement of temperature distribution on a methane-air combustor revealed some interesting characteristics. When air flow rate was kept constant, an increase in CH4 flow rate would enhance the combustion intensity and elevate the flame temperature. While under constant CH4 flow rate, the increase of air flow rate would lead the measured flame temperature first to increase and then decrease. The drop of temperature might partially be caused by the heat losses due to excessive air. However, with insufficient soot particles in the flame, the temperature could be under-evaluated.
引用
收藏
页码:378 / 382
页数:5
相关论文
共 50 条
  • [21] Numerical study on uncertainty of two-color method
    Wei, D.
    Xiao, M.
    Aketagawa, M.
    JOURNAL OF THE EUROPEAN OPTICAL SOCIETY-RAPID PUBLICATIONS, 2015, 10
  • [22] Two-Color Pyrometer for Process Temperature Measurement During Machining
    Tapetado, Alberto
    Diaz-Alvarez, Jose
    Henar Miguelez, Maria
    Vazquez, Carmen
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2016, 34 (04) : 1380 - 1386
  • [23] Whole field measurement of temperature in water using two-color laser induced fluorescence
    Sakakibara, J
    Adrian, RJ
    EXPERIMENTS IN FLUIDS, 1999, 26 (1-2) : 7 - 15
  • [24] Surface Temperature Measurement with Unknown Emissivity Using a Two-color Pyrometer Placed with a Reflector
    Che, Xunjian
    Xie, Zhi
    2017 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, AUTOMOTIVE AND MATERIALS ENGINEERING (CMAME), 2017, : 214 - 217
  • [25] Whole field measurement of temperature in water using two-color laser induced fluorescence
    J. Sakakibara
    R. J. Adrian
    Experiments in Fluids, 1999, 26 : 7 - 15
  • [26] Two-color heterodyne optical zooming method for nanometer measurement
    Wu, GH
    Zeng, LJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (07): : 2254 - 2256
  • [27] Non-contact Temperature Measurement of Micro-heaters with Two-color Method Using a Single Photon Detector
    Zhang, Wenyi
    Zhang, Enbo
    Bain, James A.
    2024 IEEE 35TH MAGNETIC RECORDING CONFERENCE, TMRC 2024, 2024,
  • [28] Study on sensitivity of two-color Z-scan method for nonlinear optical measurement
    Jia, Zhenhong
    Liu, Xin
    Jiguang Zazhi/Laser Journal, 2000, 21 (01): : 19 - 20
  • [29] A data processing method for two-Color pyrometers in accurate temperature measurement of high-temperature flow fields
    Chen, Jinlong
    Guo, Yongcai
    Wang, Dongying
    Xue, Shaoqian
    Jiao, Min
    Gao, Chao
    MEASUREMENT, 2025, 243
  • [30] Measurement of the temperature distribution within monodisperse combusting droplets in linear streams using two-color laser-induced fluorescence
    G. Castanet
    P. Lavieille
    M. Lebouché
    F. Lemoine
    Experiments in Fluids, 2003, 35 : 563 - 571