Gold nanolabels and enzymatic recycling dual amplification-based electrochemical immunosensor for the highly sensitive detection of carcinoembryonic antigen

被引:0
|
作者
ZHANG YuYong
School of Chemistry and Chemical Engineering
机构
基金
中国国家自然科学基金;
关键词
amplification; electrochemical immunosensor; carcinoembryonic antigen; redox-recycling;
D O I
暂无
中图分类号
R730.4 [肿瘤诊断学];
学科分类号
摘要
A sensitive electrochemical immunoassay system for the detection of a protein tumor biomarker through a dual amplified strategy was reported. Firstly, this protocol involves in the electropolymerization of o-aminobenzoic acid (o-ABA) on a glass carbon electrode (GCE). Subsequently, capture anti-CEA (Ab1) is covalently linked to poly(o-ABA) (PAB) film, via N-(3-dimethylamminopropyl)-N′-ethylcarbodiimide hydrochloride (EDC), and N-hydroxysulfosuccinimid sodium salt (NHS) activation of the carboxyl groups and surface blocking with ethanolamine. Later, the target, carcinoembryonic antigen (CEA), is sandwiched between an electrode surface confined Ab1 and the alkaline phosphatase-labeled signal anti-CEA antibodies conjugated with gold nanoparticles (Ab2-ALP-AuNP bioconjugates). The dual biocatalytic signal amplification for CEA mon- itoring is achieved by coupling the numerous enzymes loaded on the AuNPs with redox-recycling of the enzymatic products in the presence of the secondary enzyme and the corresponding substrate. The novel dramatic signal amplification strategy, ex- hibits a good linearity at the studied concentration range from 0.005 to 50 ng mL-1 towards CEA with a detection limit of 2 pg mL1 (S/N=3). There is a 5-100-fold improvement in detection limit compared to other similar studies. The developed dual signal amplified strategy shows good selectivity, regeneration, stability and acceptable reproducibility. Therefore, the signal amplification approach holds great potential applications in detection of ultra-trace protein biomarkers.
引用
收藏
页码:1770 / 1776
页数:7
相关论文
共 50 条
  • [41] Multiple amplification-based fluorometric aptasensor for highly sensitive detection of Staphylococcus aureus
    Chen, Wei
    Zhang, Yanke
    Lai, Qingteng
    Li, Youzhen
    Liu, Zhengchun
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2022, 106 (19-20) : 6733 - 6743
  • [42] A sensitive electrochemical biosensor for microRNA detection based on streptavidin-gold nanoparticles and enzymatic amplification
    Peng, Yunlin
    Jiang, Jianhui
    Yu, Ruqin
    ANALYTICAL METHODS, 2014, 6 (09) : 2889 - 2893
  • [43] Highly sensitive electrochemical immunosensor for the simultaneous detection of multiple tumor markers for signal amplification
    Wang, Na
    Wang, Jing
    Zhao, Xiaoqing
    Chen, Hou
    Xu, Hui
    Bai, Liangjiu
    Wang, Wenxiang
    Yang, Huawei
    Wei, Donglei
    Yuan, Baiqing
    TALANTA, 2021, 226
  • [44] Multiple amplification-based fluorometric aptasensor for highly sensitive detection of Staphylococcus aureus
    Wei Chen
    Yanke Zhang
    Qingteng Lai
    Youzhen Li
    Zhengchun Liu
    Applied Microbiology and Biotechnology, 2022, 106 : 6733 - 6743
  • [45] New Electrochemical Immunosensor of Au/Holey Graphene Oxide and Au/ZnO for Sensitive Detection of Carcinoembryonic Antigen
    Jing, Aihua
    Xu, Qiong
    Feng, Wenpo
    Li, Yu
    Liang, Gaofeng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (12): : 11212 - 11224
  • [46] Fabrication of a novel electrochemical immunosensor for the sensitive detection of carcinoembryonic antigen using a double signal attenuation strategy
    Wang, Xiao
    Liao, Xiaochen
    Zhang, Bingjian
    Chen, Siyu
    Zhang, Mengmeng
    Mei, Lisha
    Zhang, Li
    Qiao, Xiuwen
    Hong, Chenglin
    ANALYTICA CHIMICA ACTA, 2022, 1232
  • [47] Ultrasensitive analysis of carcinoembryonic antigen based on MoS2-based electrochemical immunosensor with triple signal amplification
    Su, Shao
    Sun, Qian
    Wan, Ling
    Gu, Xiaodan
    Zhu, Dan
    Zhou, Yi
    Chao, Jie
    Wang, Lianhui
    BIOSENSORS & BIOELECTRONICS, 2019, 140 : 77 - 82
  • [48] Highly Sensitive Detection of miRNA-21 Based on Electrochemical Immunosensor
    Shi, Yue
    Wang, Qi
    Xu, Fengqin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (01):
  • [49] Highly Sensitive Detection of miRNA-21 Based on Electrochemical Immunosensor
    Shi, Yue
    Wang, Qi
    Xu, Fengqin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (12):
  • [50] A highly sensitive electrochemical immunosensor based on electrospun nanocomposite for the detection of parathion
    Yin, Wen-jia
    Zhang, Jing-xian
    Wang, Hong
    Wang, Yu
    Zeng, Xi
    Xu, Zhen-lin
    Yang, Jin-yi
    Xiao, Zhi-li
    Hammock, Bruce D.
    Wen, Peng
    FOOD CHEMISTRY, 2023, 404