Geometric calibration for a SPECT system dedicated to breast imaging

被引:0
|
作者
武丽伟 [1 ,2 ]
曹学香 [1 ,3 ]
王璐 [1 ,2 ]
黄先超 [1 ]
柴培 [1 ]
贠明凯 [1 ]
张玉包 [3 ]
张龙 [3 ]
单保慈 [1 ]
魏龙 [1 ,3 ]
机构
[1] Key Laboratory of Nuclear Analysis Techniques, Institute of High Energy Physics, Chinese Academy of Sciences
[2] Graduate University of Chinese Academy of Sciences
[3] Beijing Engineering Research Center of Radiographic Techniques and Equipment
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
R816.4 [胸部及呼吸系]; TP391.41 [];
学科分类号
080203 ; 1001 ; 100105 ; 100207 ; 100602 ;
摘要
Geometric calibration is critical to the accurate SPECT reconstruction. In this paper, a geometric calibration method was developed for a dedicated breast SPECT system with a tilted parallel beam (TPB) orbit. The acquisition geometry of the breast SPECT was firstly characterized. And then its projection model was established based on the acquisition geometry. Finally, the calibration results were obtained using a nonlinear optimization method that fitted the measured projections to the model. Monte Carlo data of the breast SPECT were used to verify the calibration method. Simulation results showed that the geometric parameters with reasonable accuracy could be obtained by the proposed method.
引用
收藏
页码:1019 / 1024
页数:6
相关论文
共 50 条
  • [1] Geometric calibration for a SPECT system dedicated to breast imaging
    Wu Li-Wei
    Cao Xue-Xiang
    Wang Lu
    Huang Xian-Chao
    Chai Pei
    Yun Ming-Kai
    Zhang Yu-Bao
    Zhang Long
    Shan Bao-Ci
    Wei Long
    CHINESE PHYSICS C, 2012, 36 (10) : 1019 - 1024
  • [2] Geometric calibration for a SPECT system dedicated to breast imaging
    武丽伟
    曹学香
    王璐
    黄先超
    柴培
    贠明凯
    张玉包
    张龙
    单保慈
    魏龙
    Chinese Physics C, 2012, 36 (10) : 1019 - 1024
  • [3] Observer detection limits for a dedicated SPECT breast imaging system
    Cutler, S. J.
    Perez, K. L.
    Barnhart, H. X.
    Tornai, M. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07): : 1903 - 1916
  • [4] A high-performance SPECT-CT system for dedicated molecular breast imaging
    Tornai, M. P.
    McKinley, R. L.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (04) : 673 - 674
  • [5] Geometric calibration of a hyperspectral imaging system
    Spiclin, Ziga
    Katrasnik, Jaka
    Burmen, Miran
    Pernus, Franjo
    Likar, Bostjan
    APPLIED OPTICS, 2010, 49 (15) : 2813 - 2818
  • [6] Geometric Calibration of an OCT Imaging System
    Ourak, M.
    Tamadazte, B.
    Laurent, G. J.
    Andreff, N.
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2018, : 3993 - 3999
  • [7] Dynamic imaging with a novel dedicated cardiac SPECT system
    Huang, Qiu
    Boutchko, Rostyslav
    Reutter, Bryan
    Gullberg, Grant
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [8] Initial quantification of MIBI concentration in asymptomatic breast tissue with a dedicated SPECT-CT breast imaging system
    Mann, Steve
    Perez, Kristy
    McCracken, Emily
    Shah, Jainil
    Wong, Terence
    Choudhury, Kingshuk Roy
    Tornai, Martin
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [9] Novel Patient Optimized Acquisition Trajectories for Dedicated Breast SPECT Imaging
    Perez, Kristy L.
    Cutler, Spencer J.
    Madhav, Priti
    Tornai, Martin P.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5388 - +
  • [10] Dedicated PICO-SPECT: An approach to clinical breast imaging.
    Tornai, MP
    Bowsher, JE
    Jaszczak, RJ
    Greer, KL
    Hardenbergh, PH
    Coleman, RE
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 207P - 208P