RF deffecting cavity for bunch length measurement in Tsinghua Thomson scattering X-ray source

被引:1
|
作者
施嘉儒 [1 ,2 ]
陈怀璧 [1 ,2 ]
唐传祥 [1 ,2 ]
黄文会 [1 ,2 ]
杜应超 [1 ,2 ]
郑曙昕 [1 ,2 ]
任丽 [1 ,2 ]
机构
[1] Department of Engineering Physics, Tsinghua University
[2] Key Laboratory of Particle and Radiation Imaging of Ministry of Education, Tsinghua University
基金
中国国家自然科学基金;
关键词
RF deffecting cavity; bunch length measurement; photocathode electron gun;
D O I
暂无
中图分类号
TL503.3 [注入装置];
学科分类号
082701 ;
摘要
An RF deffecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source. The cavity is a 2856 MHz, π-mode, 3-cell standing-wave cavity, to diagnose the 3.5 MeV beam produced by photocathode electron gun. With a larger power source, the same cavity will again be used to measure the accelerated beam with energy of 50 MeV before colliding with the laser pulse. The RF design using MAFIA for both the cavity shape and the power coupler is reviewed, followed by presenting the fabrication procedure and bench measurement results of two cavities.
引用
收藏
页码:161 / 164
页数:4
相关论文
共 50 条
  • [21] Precise control and measurement of Laser-RF synchronization for Thomson-scattering X-ray source
    Du, Qiang
    Du, Yingchao
    Yan, Lixin
    Huang, Wenhui
    Li, Jianmin
    Tang, Chuanxiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 637 : S137 - S140
  • [22] In-line phase-contrast imaging based on Tsinghua Thomson scattering x-ray source
    Zhang, Zhen
    Du, Yingchao
    Yan, Lixin
    Hua, Jianfei
    Yang, Jin
    Xiao, Yongshun
    Huang, Wenhui
    Chen, Huaibi
    Tang, Chuanxiang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (08):
  • [23] Recent progress of phase-contrast imaging at Tsinghua Thomson-scattering X-ray source
    Chi, Zhijun
    Yan, Lixin
    Du, Yingchao
    Zhang, Zhen
    Huang, Wenhui
    Chen, Huaibi
    Tang, Chuanxiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2017, 402 : 364 - 369
  • [24] RF photoinjector development for a short-pulse, hard X-ray Thomson scattering source
    Le Sage, GP
    Anderson, SG
    Cowan, TE
    Crane, JK
    Ditmire, T
    Rosenzweig, JB
    ADVANCED ACCELERATOR CONCEPTS, 2001, 569 : 391 - 404
  • [25] Relativistic nonlinear Thomson scattering as attosecond x-ray source
    Lee, K
    Cha, YH
    Shin, MS
    Kim, BH
    Kim, D
    PHYSICAL REVIEW E, 2003, 67 (02):
  • [26] Preliminary study of X-ray source based on Thomson scattering
    Huang, WH
    He, XZ
    Huang, G
    Tang, CX
    Lin, YZ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (04): : 446 - 450
  • [27] Compact soft x-ray source using Thomson scattering
    Kashiwagi, S
    Kuroda, R
    Oshima, T
    Nagasawa, F
    Kobuki, T
    Ueyama, D
    Hama, Y
    Washio, M
    Ushida, K
    Hayano, H
    Urakawa, J
    JOURNAL OF APPLIED PHYSICS, 2005, 98 (12)
  • [28] Measurement of Radiative Shock Properties by X-Ray Thomson Scattering
    Visco, A. J.
    Drake, R. P.
    Glenzer, S. H.
    Doeppner, T.
    Gregori, G.
    Froula, D. H.
    Grosskopf, M. J.
    PHYSICAL REVIEW LETTERS, 2012, 108 (14)
  • [29] X-ray based subpicosecond electron bunch characterization using 90° Thomson scattering
    Univ of California at Berkeley, Berkeley, United States
    Phys Rev Lett, 20 (4182-4185):
  • [30] X-ray Thomson Scattering Measurement in shock-compressed Beryllium
    Lee, H. J.
    Doeppner, T.
    Neumayer, P.
    Castor, J.
    Falcone, R. W.
    Fortmann, C.
    Hammel, B. A.
    Kritcher, A. L.
    Landen, O. L.
    Lee, R. W.
    Meyerhofer, D. D.
    Munro, D. H.
    Redmer, R.
    Regan, S. P.
    Weber, S.
    Wallace, R.
    Glenzer, S. H.
    SIXTH INTERNATIONAL CONFERENCE ON INERTIAL FUSION SCIENCES AND APPLICATIONS, PARTS 1-4, 2010, 244