Longitudinal instability caused by long driftsin the C-ADS injector-Ⅰ

被引:0
|
作者
李智慧 [1 ]
唐靖宇 [1 ]
闫芳 [1 ]
耿会平 [1 ]
孟才 [1 ]
孙彪 [1 ]
程鹏 [1 ]
郭臻 [1 ]
孙纪磊 [1 ]
机构
[1] Institute of High Energy Physics,Chinese Academy of Sciences
基金
中国国家自然科学基金;
关键词
parametric resonance; instability; phase advance; low energy superconducting linac;
D O I
暂无
中图分类号
TL53 [直线加速器];
学科分类号
082701 ;
摘要
The period length is usually much larger than the cavity effective length in a low energy superconducting linac.The long drifts between cavities will not only decrease the acceptance of the linac, but also lead to possible instability. The linac will be more sensitive to mismatch and other perturbations. From the longitudinal motion equation, the function which describes the parametric resonance is deduced and the relation between the instability region and the cavity filling factor is discussed. It indicates that if the zero current phase advance per period is kept below 90°, instability driven by parametric resonance will never occur. The space charge effect will enhance the instability, so that a stricter limitation on the phase advance per cell is required. From the numerical simulation results for two different schemes of Injector-Ⅰ of the C-ADS driver linac, one can find that even with just three cells in the unstable region, significant emittance growth can be observed. Further investigations show that it is apt to produce halo particles under resonance, and the machine becomes more sensitive to errors and mismatches. Therefore, it is important to keep all cells in the stable region throughout the linac of very high beam power to minimize beam losses.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 36 条
  • [31] Preliminary Design of CSNS-II LINAC SRF LLRF based on C-ADS Injector I
    Xie, Zhexin
    Guo, Kai
    Mu, Zhencheng
    Liu, Huachang
    Ma, Xinpeng
    Gan, Nan
    Wang, Qunyao
    Wan, Maliang
    Wang, Bo
    Zhang, Hui
    Wang, Hexin
    Rong, Linyan
    Zhang, Cong
    Wan, Yun
    Zhou, Wenzhong
    Peng, Jun
    Lin, Haiyin
    He, Feisi
    Mi, Zhenghui
    Zhu, Peng
    Zhang, Yuliang
    Ge, Rui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [32] MTCA.4-based LLRF control system for the C-ADS proton Linac injector I
    Liu R.
    Ma X.P.
    Gan N.
    Lin H.Y.
    Wang Q.Y.
    Mi Z.H.
    Wang S.Z.
    Huang X.F.
    Wu Y.
    Wang G.W.
    Chi Y.L.
    Pan W.
    Radiation Detection Technology and Methods, 2017, 1 (1)
  • [33] Physics design for the C-ADS main linac based on two dif f erent injector design schemes
    闫芳
    李智慧
    孟才
    唐靖宇
    孙彪
    Chinese Physics C, 2014, 38 (02) : 88 - 96
  • [34] Physics design for the C-ADS main linac based on two dif f erent injector design schemes
    闫芳
    李智慧
    孟才
    唐靖宇
    孙彪
    Chinese Physics C, 2014, (02) : 88 - 96
  • [35] Magnetic Field and Strain Measurements of a Superconducting Solenoid Magnet for C-ADS Injector-II During Excitation and Quench Test
    Guan, Mingzhi
    Wang, Xingzhe
    Ma, Lizhen
    Zhou, Youhe
    Zhao, Hongwei
    Xin, Canjie
    Yang, Linliang
    Wu, Wei
    Yang, Xiaoliang
    JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2013, 26 (07) : 2361 - 2368
  • [36] Magnetic Field and Strain Measurements of a Superconducting Solenoid Magnet for C-ADS Injector-II During Excitation and Quench Test
    Mingzhi Guan
    Xingzhe Wang
    Lizhen Ma
    Youhe Zhou
    Hongwei Zhao
    Canjie Xin
    Linliang Yang
    Wei Wu
    Xiaoliang Yang
    Journal of Superconductivity and Novel Magnetism, 2013, 26 : 2361 - 2368