Three-dimensional integral imaging display system based on negative lens array

被引:0
|
作者
张雷 [1 ]
焦小雪 [1 ]
孙羽 [1 ]
王淑玲 [1 ]
谢艳 [1 ]
刘少鹏 [1 ]
机构
[1] School of Science, Hebei University of Engineering
基金
中国国家自然科学基金;
关键词
Three-dimensional integral imaging display system based on negative lens array;
D O I
暂无
中图分类号
TN873 [显示设备、显示器];
学科分类号
0810 ; 081001 ;
摘要
An integral imaging display system based on negative lens array in real mode is proposed in this letter. Compared with the conventional integral imaging system with positive lens array, the negative one has a huge advantage on viewing angle. The minimum viewing angle of the imaging display system based on negative lens array is the maximum viewing angle of the positive one with the same parameters. And the imaging display system based on negative lens array can enhance the viewing angle to 180° with special parameters. Other parameters, such as resolution and depth-of-field, are the same in both systems. Another advantage is that the proposed imaging display system based on negative lens array can fill the image area gap between 0 and 2f. The feasibility of our proposed method is experimentally proved.
引用
收藏
页码:279 / 281
页数:3
相关论文
共 50 条
  • [31] Flat dielectric metasurface lens array for three dimensional integral imaging
    Zhang, Jianlei
    Wang, Xiaorui
    Yang, Yi
    Yuan, Ying
    Wu, Xiongxiong
    [J]. OPTICS COMMUNICATIONS, 2018, 414 : 1 - 4
  • [32] Three-dimensional electro-floating display system using an integral imaging method
    Min, SW
    Hahn, M
    Kim, J
    Lee, B
    [J]. OPTICS EXPRESS, 2005, 13 (12): : 4358 - 4369
  • [33] Three-dimensional display system for medical imaging with computer-generated integral photography
    Nakajima, S
    Masamune, K
    Sakuma, I
    Dohi, T
    [J]. STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS VII, 2000, 3957 : 60 - 67
  • [34] Wide-viewing-angle three-dimensional display system using HOE lens array
    Takahashi, Hideya
    Fujinami, Hiromitsu
    Yamada, Kenji
    [J]. STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XIII, 2006, 6055
  • [35] Flatbed-type omnidirectional three-dimensional display system using holographic lens array
    Takahashi, Hideya
    Chikayama, Manabu
    Yamada, Kenji
    [J]. STEREOSCOPIC DISPLAYS AND APPLICATIONS XIX, 2008, 6803
  • [36] Calibration of the lens’ axial position error for macrolens array based integral imaging display system
    [J]. Yan, Xingpeng (yanxp02@gmail.com), 1600, Elsevier Ltd (142):
  • [37] Three-dimensional resolvability in an integral imaging system
    Kavehvash, Zahra
    Martinez-Corral, Manuel
    Mehrany, Khashayar
    Bagheri, Saeed
    Saavedra, Genaro
    Navarro, Hector
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2012, 29 (04) : 525 - 530
  • [38] Calibration of the lens' axial position error for macrolens array based integral imaging display system
    Yan, Zhan
    Yan, Xingpeng
    Jiang, Xiaoyu
    Wang, Chenqing
    Liu, Yunpeng
    Wang, Xi
    Su, Zhongting
    Jing, Tao
    [J]. OPTICS AND LASERS IN ENGINEERING, 2021, 142
  • [39] Display characteristics of one-dimensional integral imaging in virtual mode based on lenticular lens array
    Lyu, Yuan-Zhi
    Wang, Shi-Gang
    Yu, Jue-Qiong
    Wang, Xiao-Yu
    Li, Xue-Song
    [J]. Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2013, 43 (03): : 753 - 757
  • [40] Three-dimensional display system based on computer-generated integral photography
    Min, SW
    Jung, S
    Park, JH
    Lee, B
    [J]. STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS VIII, 2001, 4297 : 187 - 195