Effect of metronome rates on the quality of bag-mask ventilation during metronome-guided 30:2 cardiopulmonary resuscitation: A randomized simulation study

被引:0
|
作者
Ji Ung Na [1 ]
Sang Kuk Han [1 ]
Pil Cho Choi [1 ]
Dong Hyuk Shin [1 ]
机构
[1] Department of Emergency Medicine,Kangbuk Samsung Hospital,Sungkyunkwan University School of Medicine
关键词
Non-invasive ventilation; Resuscitation; Cardiac arrest; Cardiopulmonary resuscitation;
D O I
暂无
中图分类号
R459.7 [急症、急救处理];
学科分类号
100218 ;
摘要
BACKGROUND: Metronome guidance is a feasible and effective feedback technique to improve the quality of cardiopulmonary resuscitation(CPR). The rate of the metronome should be set between 100 to 120 ticks/minute and the speed of ventilation may have crucial effect on the quality of ventilation. We compared three different metronome rates(100, 110, 120 ticks/minute) to investigate its effect on the quality of ventilation during metronome-guided 30:2 CPR.METHODS: This is a prospective, randomized, crossover observational study using a Respi Trainer r. To simulate 30 chest compressions, one investigator counted from 1 to 30 in cadence with the metronome rate(1 count for every 1 tick), and the participant performed 2 consecutive ventilations immediately following the counting of 30. Thirty physicians performed 5 sets of 2 consecutive(total 10) bag-mask ventilations for each metronome rate. Participants were instructed to squeeze the bag over 2 ticks(1.0 to 1.2 seconds depending on the rate of metronome) and defl ate the bag over 2 ticks. The sequence of three different metronome rates was randomized.RESULTS: Mean tidal volume significantly decreased as the metronome rate was increased from 110 ticks/minute to 120 ticks/minute(343±84 m L vs. 294±90 m L, P=0.004). Peak airway pressure significantly increased as metronome rate increased from 100 ticks/minute to 110 ticks/minute(18.7 vs. 21.6 mm Hg, P=0.006).CONCLUSION: In metronome-guided 30:2 CPR, a higher metronome rate may adversely affect the quality of bag-mask ventilations. In cases of cardiac arrest where adequate ventilation support is necessary, 100 ticks/minute may be better than 110 or 120 ticks/minute to deliver adequate tidal volume during audio tone guided 30:2 CPR.
引用
收藏
页码:136 / 140
页数:5
相关论文
共 28 条
  • [21] A randomized cross-over study of the quality of cardiopulmonary resuscitation among females performing 30:2 and hands-only cardiopulmonary resuscitation
    Trowbridge C.
    Parekh J.N.
    Ricard M.D.
    Potts J.
    Patrickson W.C.
    Cason C.L.
    BMC Nursing, 8 (1)
  • [22] The effect on quality of chest compressions and exhaustion of a compression-ventilation ratio of 30:2 versus 15:2 during cardiopulmonary resuscitation -: A randomised trial
    Deschilder, Koen
    De Vos, Rien
    Stockman, Willem
    RESUSCITATION, 2007, 74 (01) : 113 - 118
  • [23] Efficacy of metronome sound guidance via a phone speaker during dispatcher-assisted compression-only cardiopulmonary resuscitation by an untrained layperson: a randomised controlled simulation study using a manikin
    Park, Sang O.
    Hong, Chong Kun
    Shin, Dong Hyuk
    Lee, Jun Ho
    Hwang, Seong Youn
    EMERGENCY MEDICINE JOURNAL, 2013, 30 (08) : 658 - U71
  • [24] Effect of socioemotional stress on the quality of cardiopulmonary resuscitation during advanced life support in a randomized manikin study
    Bjorshol, Conrad Arnfinn
    Myklebust, Helge
    Nilsen, Kjetil Lonne
    Hoff, Thomas
    Bjorkli, Cato
    Illguth, Eirik
    Soreide, Eldar
    Sunde, Kjetil
    CRITICAL CARE MEDICINE, 2011, 39 (02) : 300 - 304
  • [25] Passive continuous positive airway pressure ventilation during cardiopulmonary resuscitation: a randomized cross-over manikin simulation study
    Winkler, Bernd E.
    Muellenbach, Ralf M.
    Wurmb, Thomas
    Struck, Manuel F.
    Roewer, Norbert
    Kranke, Peter
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (01) : 93 - 101
  • [26] Passive continuous positive airway pressure ventilation during cardiopulmonary resuscitation: a randomized cross-over manikin simulation study
    Bernd E. Winkler
    Ralf M. Muellenbach
    Thomas Wurmb
    Manuel F. Struck
    Norbert Roewer
    Peter Kranke
    Journal of Clinical Monitoring and Computing, 2017, 31 : 93 - 101
  • [27] Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study
    Kwak, Se-Jung
    Kim, Young-Min
    Baek, Hee Jin
    Kim, Se Hong
    Yim, Hyeon Woo
    CLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE, 2016, 3 (03): : 148 - 157
  • [28] Effect of a feedback system on the quality of 2-minute chest compression-only cardiopulmonary resuscitation: a randomised crossover simulation study
    Wu, Chunshuang
    You, Jingyu
    Liu, Shaoyun
    Ying, Lan
    Gao, Yuzhi
    Li, Yulin
    Lu, Xiao
    Qian, Anyu
    Zhang, Mao
    Zhou, Guangju
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019,