On-line measurement of temperature and water vapor in CH4 /air premixed flame using near-infrared diode laser

被引:0
|
作者
陶波 [1 ]
叶锡生 [1 ]
胡志云 [1 ]
张立荣 [1 ]
刘晶儒 [1 ]
机构
[1] State Key Laboratory of Laser Interaction with Matter,Northwest Institute of Nuclear Technology
关键词
line; air premixed flame using near-infrared diode laser; On-line measurement of temperature and water vapor in CH4; CH;
D O I
暂无
中图分类号
TN248.4 [半导体激光器];
学科分类号
0803 ; 080401 ; 080901 ;
摘要
We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for temperature measurements.The measurements are performed on a flat burner based on scannedwavelength direct absorption spectroscopy using two adjacent water lines at 7153.75 and 7154.35 cm 1.Real-time results are acquired using a data acquisition card with a Labview data processing program.The standard uncertainties of the temperature and water concentration measurements are 2.3% and 5.1%,respectively.
引用
收藏
页码:1098 / 1101
页数:4
相关论文
共 50 条
  • [31] Investigation of Dilution Effect on CH4/Air Premixed Turbulent Flame Using OH and CH2O Planar Laser-Induced Fluorescence
    Yang, Li
    Weng, Wubin
    Zhu, Yanqun
    He, Yong
    Wang, Zhihua
    Li, Zhongshan
    ENERGIES, 2020, 13 (02)
  • [32] Two-dimensional temperature measurement of premixed CH4/Air laminar flame based on a wavelength-integrated thin-filament pyrometry
    Hu, Zongjie
    Luo, Ting
    Zhang, Junjie
    Gao, Yu
    Li, Zhilong
    GLOBAL INTELLIGENT INDUSTRY CONFERENCE 2020, 2021, 11780
  • [33] A fast-response near-infrared tunable diode laser absorption spectrometer for in situ measurements of CH4 in the upper troposphere and lower stratosphere
    E.C. Richard
    K.K. Kelly
    R.H. Winkler
    R. Wilson
    T.L. Thompson
    R.J. McLaughlin
    A.L. Schmeltekopf
    A.F. Tuck
    Applied Physics B, 2002, 75 : 183 - 194
  • [34] A fast-response near-infrared tunable diode laser absorption spectrometer for in situ measurements CH4 in the upper troposphere and lower stratosphere
    Richard, EC
    Kelly, KK
    Winkler, RH
    Wilson, R
    Thompson, TL
    McLaughlin, RJ
    Schmeltekopf, AL
    Tuck, AF
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3): : 183 - 194
  • [36] Precise measurement of the 13CH4/12CH4 ratio of diluted methane using a near-infrared laser absorption spectrometer
    Tsuji, K
    Fujikawa, S
    Yamada, K
    Yoshida, N
    Yamamoto, K
    Kikugawa, T
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) : 326 - 333
  • [37] Temperature and CO concentration measurements in a partially premixed CH4/air coflowing jet flame using coherent anti-Stokes Raman scattering
    Datta, A
    Beyrau, F
    Seeger, T
    Leipertz, A
    COMBUSTION SCIENCE AND TECHNOLOGY, 2004, 176 (11) : 1965 - +
  • [38] Near-infrared compressive line sensing imaging system using individually addressable laser diode array
    Ouyang, Bing
    Hou, Weilin
    Caimi, Frank M.
    Dalgleish, Fraser R.
    Vuorenkoski, Anni K.
    Gong, Sue
    Britton, Water
    COMPRESSIVE SENSING IV, 2015, 9484
  • [39] Effects of Carbon Dioxide and Water Vapor Addition on Benzene and PAH Formation in a Laminar Premixed CH4/O2/Ar Flame
    Wu, Yuxin
    Liu, Fengshan
    Sun, Yunlan
    Zhu, Baozhong
    COMBUSTION SCIENCE AND TECHNOLOGY, 2019, 191 (10) : 1866 - 1897
  • [40] A fibered near-infrared laser heterodyne radiometer for simultaneous remote sensing of atmospheric CO2 and CH4
    Wang, Jingjing
    Sun, Chunyan
    Wang, Guishi
    Zou, Mingmin
    Tan, Tu
    Liu, Kun
    Chen, Weidong
    Gao, Xiaoming
    OPTICS AND LASERS IN ENGINEERING, 2020, 129