Application of Direct Ignition Technology with Minimum Gasified Oil in Lignite-Fired Boiler

被引:1
|
作者
Peng Lixia1
2. Heilongjiang Power Co.
3. Heilongjiang Electric Power Research Institute Wang Ben
机构
关键词
rate; Application of Direct Ignition Technology with Minimum Gasified Oil in Lignite-Fired Boiler;
D O I
暂无
中图分类号
TM621.2 [锅炉及燃烧系统];
学科分类号
080802 ;
摘要
The firing is in the stable condition and the rate of oil saving comes up to 64%, after Fularji Power Plant adopted the technology of minimum gasified oil igniting pulverized lignite directly and the technology of multistage coal combustion with energy amplified stage by stage.
引用
收藏
页码:31 / 35
页数:5
相关论文
共 50 条
  • [21] Numerical examination of an operationally flexible lignite-fired boiler including its convective section using as supporting fuel pre-dried lignite
    Drosatos, P.
    Nikolopoulos, N.
    Nikolopoulos, A.
    Papapavlou, Ch.
    Grammelis, P.
    Kakaras, E.
    FUEL PROCESSING TECHNOLOGY, 2017, 166 : 237 - 257
  • [22] Study of the influence of vane angle on flow, gas species, temperature, and char burnout in a 200 MWe lignite-fired boiler
    Jing, Jianping
    Li, Zhengqi
    Chen, Zhichao
    Liu, Guangkui
    Liu, Chunlong
    FUEL, 2010, 89 (08) : 1973 - 1984
  • [23] Research and Application of Minimal-oil Ignition Technology on Pulverized Coal Fired Boilers
    Zhang, Wei
    Wei, Hong-Qiang
    Xu, Li-Hai
    Li, Jing-Tao
    Li, Fu-Ming
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 2775 - +
  • [24] Numerical simulation of the tiny-oil ignition burner in the coal fired boiler
    Key Lab. of Condition Monitoring and Control of Power Equipment, North China Electric Power University, Beijing 102206, China
    Kung Cheng Je Wu Li Hsueh Pao, 2008, 4 (609-612):
  • [25] Enhancing the overall efficiency of a lignite-fired oxyfuel power plant with CFB boiler and membrane-based air separation unit
    Kotowicz, Janusz
    Balicki, Adrian
    ENERGY CONVERSION AND MANAGEMENT, 2014, 80 : 20 - 31
  • [26] Exergy analysis of the flue gas pre-dried lignite-fired power system based on the boiler with open pulverizing system
    Han, Xiaoqu
    Liu, Ming
    Wu, Kaili
    Chen, Weixiong
    Xiao, Feng
    Yan, Junjie
    ENERGY, 2016, 106 : 285 - 300
  • [27] BIG-BROWN-GENERATING-STATION - NEW-TECHNOLOGY FABRIC FILTER IS CHOICE AT LIGNITE-FIRED PLANT
    PAFIMENI, SR
    MCKENNA, TA
    POWER, 1994, 138 (04) : 93 - 95
  • [28] Towards the improvement of thermal efficiency in lignite-fired power generation: Concerning the utilization of Polish lignite deposits in state-of-the-art IGCC technology
    Komatsu, Yosuke
    Sciazko, Anna
    Zakrzewski, Marcin
    Akiyama, Taro
    Hashimoto, Akira
    Shikazono, Naoki
    Kaneko, Shozo
    Kimijima, Shinji
    Szmyd, Janusz S.
    Kobayashi, Yoshinori
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2016, 40 (13) : 1757 - 1772
  • [29] Assessment of gaseous, PM and trace element emissions from a 300-MW lignite-fired boiler unit for various fuel qualities
    Kuprianov, V. I.
    Tanetsakunvatana, V.
    FUEL, 2006, 85 (14-15) : 2171 - 2179
  • [30] Numerical Study on Effect of Flue Gas Recirculation and Co-Firing with Biomass on Combustion Characteristics in Octagonal Tangentially Lignite-Fired Boiler
    Du, Jiajun
    Yang, Jiahui
    Zhao, Yonggang
    Guo, Qianxin
    Da, Yaodong
    Che, Defu
    ENERGIES, 2024, 17 (02)