Computation and parameterization of normalized glandular dose using Geant4

被引:1
|
作者
Omrane Kadri [1 ,2 ]
Mohammed Ali Alnafea [1 ]
Khaled Shamma [1 ]
机构
[1] Department of Radiological Sciences, College of Applied Medical Sciences,King Saud University
关键词
Monte Carlo simulation; Geant4; Normalized glandular dose; Parameterization;
D O I
10.13538/j.1001-8042/nst.26.030303
中图分类号
R816.8 [外科、骨科];
学科分类号
1001 ; 100105 ; 100207 ; 100602 ;
摘要
The average absorbed dose in glandular tissue is the most appropriate parameter for the assessment of the radiation-induced risk during breast imaging. The aims of this work concern:(1) the investigation of the variation effect of any related update to photon cross-section data-bases on the computation of the normalized glandular dose(Dg N) for mammography quality control tests and(2) the proposition of a parameterization method leading to provide Dg N values function of the breast thickness(T) and the particle energy(E) instead of E alone, as normally known. We analyzed the change effect of the photon cross-section data-bases on the computation of Dg N. Those coefficients, generated using the Geant4 Monte Carlo toolkit, were studied over a range of compressed breast thickness of 2–8 cm for monoenergetic(1–120 ke V by 1 ke V intervals) and polyenergetic(23–35 k Vp by 2 k Vp intervals) X-ray beams. Moreover, breast tissue composition ranging from about0% glandular(about 100% adipose) to 100% glandular(0% adipose) was also covered. The successful parameterization of Dg N look-up table function of the breast thickness and energy, will compact its analytical form without loss of accuracy. All parameterization fits resulted in r2 values of 0.999 or better.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [1] Computation and parameterization of normalized glandular dose using Geant4
    Kadri, Omrane
    Alnafea, Mohammed Ali
    Shamma, Khaled
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (03)
  • [2] DOSE CALIBRATOR MODELLING WITH GEANT4
    O'Keefe, G.
    [J]. INTERNAL MEDICINE JOURNAL, 2018, 48 : 10 - 11
  • [3] Calculating the Outdoor Dose Deposited by γ-Photons Using GEANT4
    Argintaru, Danut
    Baban, Valerica
    Constantinescu, Eliodor
    [J]. ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS, AND NANOTECHNOLOGIES V, 2010, 7821
  • [4] Calculating the Indoor Dose Deposited by γ-Photons Using GEANT4
    Argintaru, Danut
    Baban, Valerica
    Constantinescu, Eliodor
    [J]. ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS, AND NANOTECHNOLOGIES V, 2010, 7821
  • [5] Geant4 Benchmarking for IMRT Dose Calculations
    Hancox, C.
    Seco, J.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [6] Influence of Geant4 parameters on dose distribution and computation time for carbon ion therapy simulation
    Zahra, Nabil
    Frisson, Thibault
    Grevillot, Loic
    Lautesse, Philippe
    Sarrut, David
    [J]. PHYSICA MEDICA, 2010, 26 (04) : 202 - 208
  • [7] Normalized mean glandular dose computation from mammography using GATE: a validation study
    Myronakis, Marios E.
    Zvelebil, Marketa
    Darambara, Dimitra G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2247 - 2265
  • [8] The Geant4 Simulation Toolkit and Applications For the Geant4 Collaboration
    Apostolakis, John
    [J]. MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 73 - 92
  • [9] Study on GEANT4 code applications to dose calculation using imaging data
    Jeong Ok Lee
    Jeong Ku Kang
    Jhin Kee Kim
    Hyeong Cheol Kwon
    Jung Soo Kim
    Bu Gil Kim
    Dong Hyeok Jeong
    [J]. Journal of the Korean Physical Society, 2015, 67 : 195 - 198
  • [10] Study on GEANT4 Code Applications to Dose Calculation Using Imaging Data
    Lee, Jeong Ok
    Kang, Jeong Ku
    Kim, Jhin Kee
    Kwon, Hyeong Cheol
    Kim, Jung Soo
    Kim, Bu Gil
    Jeong, Dong Hyeok
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 195 - 198