Ventilation of air-conditioned residential buildings: A case study in Hong Kong

被引:0
|
作者
Z.T.Ai [1 ]
C.M.Mak [1 ]
D.J.Cui [1 ]
P.Xue [1 ]
侯恩哲 [1 ]
机构
[1] 《建筑节能》杂志社
关键词
Ventilation; Room air conditioner; Residential buildings; Carbon dioxide(CO2); On-site measurements;
D O I
暂无
中图分类号
TU83 [空气调节、采暖、通风及其设备];
学科分类号
081404 ;
摘要
More and more studies reported that there were insufficient ventilation and excessive CO;concentration in air-conditioned residential buildings, but few solutions were provided. This study investigates the overnight evolution of CO;concentration in air-conditioned residential buildings and then focuses mainly on the evaluation of three ventilation strategies, including overnight natural ventilation, short-term mechanical ventilation and short-term natural ventilation. On-site measurements were conducted in a typical residential bedroom in Hong Kong in September. The indoor and outdoor CO;concentration, air temperature and relative humidity as well as the outdoor wind speed during the measurements were analysed. Ventilation rates were calculated based on the time series of CO;concentration. This study confirms that additional ventilation is usually needed in air-conditioned residential buildings. Overnight natural ventilation with even a small opening is associated with excessive energy consumption and deteriorated indoor thermal environment. Short-term natural ventilation strategies are inefficient and uncontrollable. Compared to the best short-term natural ventilation strategy, a reasonably designed short-term mechanical ventilation strategy requires only a 41% of ventilation period to complete one full replacement of indoor air and to reach a lower indoor CO;concentration. Nighttime case studies and a theoretical analysis suggest that a few several-minute mechanical ventilation periods could potentially maintain an acceptable indoor air quality for a normal sleeping period of 8 h.
引用
收藏
页码:5 / 5
页数:1
相关论文
共 50 条
  • [31] Investigation of indoor air quality at residential homes in Hong Kong - case study
    Lee, SC
    Li, WM
    Ao, CH
    ATMOSPHERIC ENVIRONMENT, 2002, 36 (02) : 225 - 237
  • [32] CHARACTERISTICS OF ELECTRICITY CONSUMPTION IN COMMERCIAL BUILDINGS - SURVEY OF ELECTRICITY CONSUMPTION IN FULLY AIR-CONDITIONED OFFICE BUILDINGS AND HOTELS IN HONG-KONG, IMPLICATIONS FOR ENERGY-CONSERVATION IN BUILDINGS
    LAM, JC
    CHAN, ALS
    BUILDING RESEARCH AND INFORMATION, 1994, 22 (06): : 313 - 318
  • [33] A PARAMETRIC STUDY OF THE ENERGY EFFICIENCY OF EXISTING AIR-CONDITIONED BUILDINGS IN KUWAIT
    Kulaib, Aboelyazied
    Kalendar, Abdulrahim
    Hussain, Shafqat
    Alhendal, Yousuf
    JOURNAL OF GREEN BUILDING, 2021, 16 (01): : 163 - 178
  • [34] Evaluating the Influence of Window Types on the Natural Ventilation Performance of Residential Buildings in Hong Kong
    Gao, C. F.
    Lee, W. L.
    INTERNATIONAL JOURNAL OF VENTILATION, 2011, 10 (03) : 227 - 238
  • [35] Using Rn-222 to manage the air quality of air conditioned buildings in Hong Kong
    Chan, Daniel W. T.
    Wong, C. S.
    Tung, Thomas C. W.
    INDOOR AND BUILT ENVIRONMENT, 2008, 17 (05) : 467 - 471
  • [36] Influence of window opening degree on natural ventilation performance of residential buildings in Hong Kong
    Liu, Tianqi
    Lee, W. L.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (01) : 28 - 41
  • [37] INDOOR/OUTDOOR AIR POLLUTANT RELATIONSHIPS FOR AIR-CONDITIONED BUILDINGS
    YOCUM, JE
    COTE, WA
    ASHRAE JOURNAL, 1971, 13 (01): : 54 - &
  • [38] Indoor and outdoor air quality investigation at six residential buildings in Hong Kong
    Lee, SC
    Chang, M
    Chan, KY
    ENVIRONMENT INTERNATIONAL, 1999, 25 (04) : 489 - 496
  • [39] Indoor and outdoor air quality investigation at six residential buildings in Hong Kong
    Lee, Shun-Cheng
    Chang, Maureen
    Chan, Ka-Yee
    Environment International, 1999, 25 (04): : 489 - 496
  • [40] Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildings
    Wu, PC
    Li, YY
    Chiang, CM
    Huang, CY
    Lee, CC
    Li, FC
    Su, HJ
    INDOOR AIR, 2005, 15 (01) : 19 - 26