Electromagnetic Environmental Impact of 500-kV Double -Circuit Transmission Lines

被引:0
|
作者
Qi Jianzhao
机构
关键词
transmission line; frequency electric field intensity; frequency magnetic field strength;
D O I
暂无
中图分类号
TM726 [输配电线路];
学科分类号
080802 ;
摘要
The strength of the power frequency electric intensity and magnetic field of the 500-kV double circuit transmission lines was calculated by using the equivalent charge method and the Ampere’s Law, and the environmental impact factors of the fields were evaluated. By optimizing the phase sequence, the frequency electric intensity and magnetic field strength can be reduced. Within a distance of 25 m from the center of the transmission line, the power frequency electric intensity and magnetic field strength fall off sharply with the distance increase. Finally, the best phase sequence and the minimum ground clearance of the transmission lines were obtained to meet the requirements of the least impact on envionment.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [31] Development of 500-kV XLPE cables and accessories for long-distance underground transmission lines .5. Long-term performance for 500-kV XLPE cables and joints
    Kaminaga, K
    Ichihara, M
    Jinno, M
    Fujii, O
    Fukunaga, S
    Kobayashi, M
    Watanabe, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1185 - 1194
  • [32] Shanghai 500-kV Jing’an transmission & substation project completed
    Liu Chunsheng
    Electricity, 2010, 21 (02) : 3 - 3
  • [33] 500-KV TRANSMISSION-LINE RADIO NOISE PERFORMANCE
    PRIEST, KW
    WILLIAMS.DR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (06): : 1744 - 1744
  • [34] 5005 ALLOY CONDUCTOR FOR VEPCO 500-KV TRANSMISSION LINE
    RAWLS, JA
    ADAMS, HW
    SMALLING, CA
    HONDALUS, B
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (06): : 573 - &
  • [35] INSULATION PERFORMANCE ANALYSIS OF A 500-KV TRANSMISSION LINE DESIGN
    ANNESTRAND, S
    BOSSUYT, EF
    REPPEN, ND
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (03): : 429 - +
  • [36] Lightning performance of 500-kV double-circuit line schemes for the three-gorge project
    Huang, WG
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 736 - 743
  • [37] BPA 500-KV TRANSMISSION-LINE AND SUBSTATION DESIGN
    STEVENS, RF
    DAVIES, IT
    MARJERRISON, MN
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (06): : 687 - +
  • [38] ANALYSIS OF ELECTRIC AND MAGNETIC-FIELDS MEASURED NEAR TVAS 500-KV TRANSMISSION-LINES
    SENDAULA, M
    HILSON, DW
    MYERS, RC
    AKENS, LG
    WOOLERY, BJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (02): : 328 - 336
  • [39] A 500-KV CIRCUIT BREAKER USING SF6 GAS
    VANSICKLE, RC
    YECKLEY, RN
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (10): : 892 - +
  • [40] Effect of Line Voltage on Lightning Attachment to 220-kV and 500-kV Lines
    Podporkin, Georgy
    2017 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIV SIPDA), 2017, : 7 - 13