Dual Torch Plasma Arc Furnace for Medical Waste Treatment

被引:0
|
作者
刘斌 [1 ]
M.KIKUCHI [1 ]
李和平 [2 ]
T.IWAO [3 ]
T.INABA [1 ]
机构
[1] Graduate School of Science and Engineering,Chuo University,Tokyo 112-8551,Japan
[2] Department of Engineering Physics,Tsinghua University,Beijing 100084,China
[3] Faculty of Engineering,Musashi Institute of Technology,Tokyo 158-8557,Japan
关键词
dual torch; plasma arc furnace; medical waste;
D O I
暂无
中图分类号
O539 [等离子体物理的应用];
学科分类号
摘要
In this paper,characteristics of a dual torch plasma arc used for hazardous wastetreatment and operated at atmospheric pressure are studied,and also compared with those of themulti-torch plasma arc and the single torch plasma arc.The dual torch plasma arc is generatedbetween the cathode and anode with argon as the working gas.The temperature distributionsof the plasma arc are measured using a spectroscope and line pair method with the assumptionof local thermodynamic equilibrium (LTE) for the DC arc current I=100 A and argon flow rateQ = 15 slpm.The measurements show that the temperatures of the dual torch arc plasma in theregions near the cathode,the anode and the center point are 10,000 K,11,000 K and 9,000 K,respectively.And the high temperature region of the multi torch plasma arc is of double or muchwider size than that of a conventional dual torch plasma arc and single plasma torch.Based onthe preceding studies,a dual torch plasma arc furnace is developed in this study.The measuredgas temperature at the center region of the argon arc is about 11,000 K for the case of I = 200 Aand Q=30 slpm operated in atmosphere.
引用
收藏
页码:709 / 712
页数:4
相关论文
共 50 条
  • [41] Analysis of the Impact of Plasma Jet Mode on Medical Waste Gasification Furnace
    Shi, Haoyang
    Wang, Pingyang
    Wang, Shu
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (06) : 2157 - 2167
  • [42] Plasma arc systems for waste treatment and metal recovery
    Eschenbach, RC
    JOM-JOURNAL OF THE MINERALS METALS & MATERIALS SOCIETY, 1996, 48 (06): : 49 - 52
  • [43] Plasma arc systems for waste treatment and metal recovery
    Purdue University
    不详
    不详
    不详
    JOM, 6 (49-52):
  • [44] Plasma length on characteristics of DC argon plasma torch arc
    Iwao, T
    Inaba, T
    VACUUM, 2002, 65 (3-4) : 299 - 304
  • [45] THE TREATMENT OF ELECTRIC-ARC FURNACE (EAF) STEEL PLANT DUSTS IN THE TETRONICS PLASMA FURNACE
    COWX, PM
    CHAPMAN, CD
    JOURNAL OF METALS, 1988, 40 (11): : 40 - 41
  • [46] Treatment of Hazardous Waste by Carbon Dioxide Capture from an Electric Arc Furnace
    Leon, Gustavo
    Cantu, Rodrigo
    Villarreal, Juan A.
    Micheloud, Osvaldo M.
    Montesinos-Castellanos, Alejandro
    ISIJ INTERNATIONAL, 2015, 55 (03) : 559 - 563
  • [47] Numerical analysis and experiment on a plasma torch with hollow electrodes for hazardous waste treatment
    Hur, M
    Cho, H
    Hong, SH
    HEAT AND MASS TRANSFER UNDER PLASMA CONDITIONS, 1999, 891 : 49 - 56
  • [48] Modeling and Performance Analysis of Municipal Solid Waste Treatment in Plasma Torch Reactor
    Elaissi, Samira
    Alsaif, Norah A. M.
    SYMMETRY-BASEL, 2023, 15 (03):
  • [49] Study of double-chamber air arc plasma torch and the application in solid-waste disposal
    曹亚文
    李斌
    韩先伟
    谭畅
    张志豪
    张晰哲
    魏建国
    Plasma Science and Technology, 2021, (06) : 57 - 67
  • [50] Study of double-chamber air arc plasma torch and the application in solid-waste disposal
    Cao, Yawen
    Li, Bin
    Han, Xianwei
    Tan, Chang
    Zhang, Zhihao
    Zhang, Xizhe
    Wei, Jianguo
    PLASMA SCIENCE & TECHNOLOGY, 2021, 23 (06)