ELECTRONIC MONITORING OF FETAL HEART RATE AND DETERMINATION OF FETAL SCALP BLOOD pH IN PREDICTION OF INTRAPARTUM FETAL DISTRESS

被引:0
|
作者
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A prospective study on consecutive fetal monitoring in 559 deliveries was carried out. The difference between the first 30-minute and the last 30-minute monitoring was compared. Abnormal fetal heart rate (FHR) pattern in the last 30 minutes combined with abnormal fetal scalp blood pH has a good predictability of 1- and 5-minute Apgar scores. The correlation of fetal heart rate-uterine contraction (FHR-UC) monitoring (525 cases) and fetal scalp blood pH determinations (FSB-pH) (79 cases) with the fetal condition was assessed. It is indicated that the first 30-minute FHR tracing can reflect the fetal status in labor, and FHR-UC monitoring assessment is evidently superior to FSB-pH in the prediction of a vigorous fetus. Whereas, FSB-pH is superior to FHR-UC monitoring in the prediction of a compromised fetus.
引用
收藏
页码:132 / 137
相关论文
共 50 条
  • [41] Fetal ECG Analysis for Intrapartum Electronic Fetal Monitoring: A Review
    Devoe, Lawrence D.
    [J]. CLINICAL OBSTETRICS AND GYNECOLOGY, 2011, 54 (01): : 56 - 65
  • [42] INTRAPARTUM FETAL HEART-RATE PATTERNS AND FETAL OUTCOME - PREDICTION OF NEWBORN DEPRESSION
    RICHTER, R
    HOHL, M
    LUSCHER, KP
    STUCKI, D
    [J]. ZEITSCHRIFT FUR GEBURTSHILFE UND PERINATOLOGIE, 1979, 183 (04): : 264 - 271
  • [43] ELECTRONIC FETAL HEART-RATE MONITORING DURING CESAREAN-SECTION IN CASES OF FETAL DISTRESS
    PETRIKOVSKY, BM
    COHEN, M
    TANCER, ML
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1989, 29 (03) : 215 - 218
  • [44] Predicting normal pH with Intrapartum electronic fetal monitoring (EFM)
    Cahill, Alison G.
    Tuuli, Methodius G.
    Stout, Molly J.
    Deych, Elena
    Shannon, William
    Macones, George A.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 214 (01) : S250 - S251
  • [45] INTRAPARTUM ELECTRONIC FETAL MONITORING EFFICACY
    FRIBOURG, S
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 157 (04) : 1013 - 1014
  • [46] THE EFFICACY OF INTRAPARTUM ELECTRONIC FETAL MONITORING
    THACKER, SB
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 156 (01) : 24 - 30
  • [47] Intrapartum fetal pulse oximetry and fetal heart rate decelerations
    Puertas, A
    Navarro, M
    Velasco, R
    Montoya, E
    Miranda, JA
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2004, 85 (01) : 12 - 17
  • [48] COMPARISON OF INTRAPARTUM ELECTRONIC FETAL HEART-RATE MONITORING VERSUS INTERMITTENT AUSCULTATION IN DETECTING FETAL ACIDEMIA AT BIRTH
    VINTZILEOS, AM
    NOCHIMSON, DJ
    ANTSAKLIS, A
    VARVARIGOS, I
    GUZMAN, ER
    KNUPPEL, RA
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 173 (04) : 1021 - 1024
  • [49] Intrapartum fetal distress
    Dastur, Adi E.
    [J]. JOURNAL OF OBSTETRICS AND GYNECOLOGY OF INDIA, 2005, 55 (02): : 115 - 117
  • [50] CONTINUOUS INTRAPARTUM FETAL SCALP TISSUE PH AND ECG MONITORING BY A FIBEROPTIC PROBE
    HOCHBERG, HM
    ROBY, PV
    SNELL, HM
    SMITH, WD
    CHATTERJEE, MS
    [J]. JOURNAL OF PERINATAL MEDICINE, 1988, 16 : 71 - 86