The Representativeness of Air Quality Monitoring Sites in the Urban Areas of a Mountainous City

被引:0
|
作者
Minjin MA [1 ]
Yue CHEN [1 ]
Fan DING [2 ]
Zhaoxia PU [3 ]
Xudong LIANG [4 ]
机构
[1] College of Atmospheric Sciences, Lanzhou University
[2] State Key Laboratory of Severe Weather, Chinese Academy of Meteorological Sciences
[3] College of Computer and Communication, Lanzhou University of Technology
[4] Department of Atmospheric Sciences, University of Utah
基金
国家重点研发计划;
关键词
mountainous cities; air quality monitoring; site representativeness;
D O I
暂无
中图分类号
X831 [大气监测];
学科分类号
0706 ; 070602 ;
摘要
Lanzhou is a typical mountainous city with severe air pollution in northwestern China. This study uses hourly observational data of air pollutants at five air quality monitoring sites in Lanzhou from July to December 2015 to discuss data quality control and the representativeness of the monitoring sites(four urban sites and one suburban site). A fuzzy matrix is applied to study primary air pollutants. The results show that of the six routinely monitored pollutants,the primary pollutant is PM0 during the study period. Based on lag correlation analysis and one-way analysis of variance, it is concluded that there are redundant observations at the four urban sites for the timely diffusion and transport of air pollutants from the same general area. The coefficient of divergence(COD) method is then used to evaluate the spatial distribution differences, and the primary air pollutant PM0 shows differences at each site. COD can be used as a positive indicator to describe site representativeness. To evaluate the overall air pollution in the valley, correlation analysis is performed between the PM0 concentration retrieved from aerosol optical depth satellite data and the concentration from the four urban monitoring sites. Among these, the correlation between the workers’ hospital site data and the retrieval data is the highest, passing the 90% confidence level. A new representative evaluation model for air quality monitoring sites, R= 0.77 COD + 0.23R, is established by using COD and correlation coefficients between routine observations and satellite retrieval products. From this model, it can be concluded that the biological products institute site in Lanzhou is the most representative site for the evaluation of air pollution out of the four urban air quality monitoring sites from July to December 2015.
引用
收藏
页码:236 / 250
页数:15
相关论文
共 50 条
  • [21] Air Quality Mon Air Quality Monitoring in Selected Urban Areas in Myanmar during 2007-2008
    Tin Hlaing Ohnmar May
    Swe Than Than
    Htwe Tin Nwe
    Aye Myo Myo
    Htwe Yi Yi
    Maw Aung Myint
    Lwin Phone
    [J]. PROGRESS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, VOL II, PTS A AND B, 2009, : 545 - 556
  • [22] Air quality in Kuwait urban areas
    Matar, Hamad B.
    Al-Otaibi, Fahad A.
    Almutairi, Saad K.
    Alhubail, Jamal A.
    [J]. ENVIRONMENTAL QUALITY MANAGEMENT, 2024, 33 (03) : 555 - 566
  • [23] View: implementing low cost air quality monitoring solution for urban areas
    Jahangir Ikram
    Amer Tahir
    Hasanat Kazmi
    Zonia Khan
    Rabi Javed
    Usama Masood
    [J]. Environmental Systems Research, 1 (1):
  • [24] The importance of local scale for assessing, monitoring and predicting of air quality in urban areas
    Ortolani, Chiara
    Vitale, Marcello
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2016, 26 : 150 - 160
  • [25] AIR QUALITY IN A MOUNTAINOUS CITY: A CASE STUDY IN CHONGQING, CHINA
    Wang, Shu-min
    Yu, Hui
    Song, Li
    Xie, Yun-cheng
    Zhu, Qi-hong
    [J]. FRESENIUS ENVIRONMENTAL BULLETIN, 2015, 24 (09): : 2699 - 2706
  • [26] Representativeness of an air quality monitoring station for PM2.5 and source apportionment over a small urban domain
    Yatkin, S.
    Gerboles, M.
    Belis, C. A.
    Karagulian, F.
    Lagler, F.
    Barbiere, M.
    Borowiak, A.
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2020, 11 (02) : 225 - 233
  • [27] On air quality monitoring in industrial areas
    Ando, B
    Baglio, S
    Condurso, D
    Graziani, S
    Pitrone, N
    [J]. WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 325 - 329
  • [28] Monitoring air quality with lichens: A comparison between mapping in forest sites and in open areas
    Policnik, Helena
    Simoncic, Primoz
    Batic, Franc
    [J]. ENVIRONMENTAL POLLUTION, 2008, 151 (02) : 395 - 400
  • [29] AIR QUALITY MONITORING IN MEGA CITY
    Nakata, Makiko
    [J]. 2014 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2014, : 4135 - 4138
  • [30] Assessment of parameters describing representativeness of air quality in-situ measurement sites
    Henne, S.
    Brunner, D.
    Folini, D.
    Solberg, S.
    Klausen, J.
    Buchmann, B.
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2010, 10 (08) : 3561 - 3581