Behaviour tree based control strategies for resilient heat pump operation in residential buildings

被引:0
|
作者
Urban, Piet [1 ]
Klement, Peter [1 ]
Schlueters, Sunke [1 ]
Schoenfeldt, Patrik [1 ]
机构
[1] DLR Inst Networked Energy Syst, Carl von Ossietzky Str 15, D-26129 Oldenburg, Germany
关键词
Behaviour tree; Decision tree; CART; Optimisation; MILP; Heat pump; Energy management; Machine learning; FRAMEWORK;
D O I
10.1016/j.egyr.2024.12.039
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Behaviour trees area proven concept in the creation of complex task-switching control and artificial intelligence for robotic systems and non-player characters in the computer games industry. Requirements such as flexibility, maintainability, reusability of functionalities or expandability also apply to the control of decentralised energy systems. Despite this, there is a noticeable research gap regarding the application of behaviour trees in that sector. Based on a foundational heating system, including thermodynamic modelling of a part-load capable heat pump with TESPy, tree structures for its control are created using the Python library py_trees for implementation. With a view to minimising the annual operational performance indicators electricity price and CO2 emissions, which reflect the optimal use of renewable shares, several control strategies are compared. We identify and illustrate the principal limitations of decision trees, mixed-integer linear optimisation performed with oemof-solph, as well as a classic rule-based approach. The proposed higher-level behaviour tree combines the strengths of such approaches whilst pursuing the additional target of reducing the start-up and associated wear of the heat pump without significantly increasing the computation time.
引用
收藏
页码:1054 / 1068
页数:15
相关论文
共 50 条
  • [41] Joint Optimization of HVAC and Active Insulation Control Strategies in Residential Buildings
    Sepehri, Amin
    Pavlak, Gregory
    ASHRAE TRANSACTIONS 2022, VOL 128, PT 2, 2022, 128 : 132 - 139
  • [42] Demand Control Strategies of a PCM Enhanced Ventilation System for Residential Buildings
    Hu, Yue
    Heiselberg, Per Kvols
    Larsen, Tine Steen
    APPLIED SCIENCES-BASEL, 2020, 10 (12):
  • [43] Demand-Based Control Design for Efficient Heat Pump Operation of Electric Vehicles
    Dvorak, Dominik
    Basciotti, Daniele
    Gellai, Imre
    ENERGIES, 2020, 13 (20)
  • [44] Investigation of Heat Pump Operation Strategies with Thermal Storage in Heating Conditions
    Jung, Wangsik
    Kim, Dongjun
    Kang, Byung Ha
    Chang, Young Soo
    ENERGIES, 2017, 10 (12)
  • [45] Estimation of energy efficiency of heat pumps in residential buildings using real operation data
    Brudermueller, Tobias
    Potthoff, Ugne
    Fleisch, Elgar
    Wortmann, Felix
    Staake, Thorsten
    NATURE COMMUNICATIONS, 2025, 16 (01)
  • [46] Analysis of a HVAC zoning control system with an air-to-water heat pump and a ducted fan coil unit in residential buildings
    Hernandez, Francisco Fernandez
    Atienza-Marquez, Antonio
    Suarez, Jose Miguel Pena
    Cantalejo, Juan Antonio Bandera
    Muriano, Mari Carmen Gonzalez
    APPLIED THERMAL ENGINEERING, 2022, 215
  • [47] Analysis of the Operation of an Aerothermal Heat Pump in a Residential Building Using Building Information Modelling
    Torregrosa-Jaime, Barbara
    Gonzalez, Benjamin
    Martinez, Pedro J.
    Paya-Ballester, Gaspar
    ENERGIES, 2018, 11 (07):
  • [48] How window ventilation behaviour affects the heat resilience in multi-residential buildings
    Schunemann, Christoph
    Schiela, David
    Ortlepp, Regine
    BUILDING AND ENVIRONMENT, 2021, 202
  • [49] Control strategy for the operation of a reversible heat-pump in greenhouses
    Applied Engineering in Agriculture, 1995, 11 (06):
  • [50] Seasonal COP of a residential magnetocaloric heat pump based on MnFePSi
    Quijano, Diego Pineda
    Lima, Beatriz Fonseca
    Ferreira, Carlos Infante
    Bruck, Ekkes
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 164 : 38 - 48