Study on Measurement Method and Influencing Factors of Surface Temperature for Rock Under Microwave Irradiation

被引:0
|
作者
Ma, Zhongjun [1 ]
Zhao, Xiaobao [2 ]
Yang, Shuo [2 ]
Zheng, Yanlong [3 ]
Long, Yangwei [2 ]
Che, Ping [4 ]
机构
[1] Ningbo Univ, Inst Rock Mech, Ningbo 315211, Peoples R China
[2] Nanjing Univ, Sch Earth Sci & Engn, Nanjing 210093, Peoples R China
[3] Southeast Univ, Sch Civil Engn, Nanjing 211189, Peoples R China
[4] Jiangsu East China Geol Construct Grp Co Ltd, Nanjing 210000, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Microwave rock breaking; Real-time temperature measurement; Non-real-time temperature measurement; Temperature correction model;
D O I
10.1007/s00603-025-04403-0
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Temperature is crucial for evaluating the effectiveness and understanding the mechanisms of microwave-induced rock weakening. However, the measurement of actual temperature for microwave-treated rock using real-time and non-real-time methods, as well as its influencing factors, have not been systematically studied. In this paper, the cooling processes of rock surface after multimode microwave heating was first investigated using the non-real-time temperature measurement method (with an infrared thermal imager). The effects of initial temperature, wind speed, and cooling time on rock surface temperature were preliminarily investigated. On this basis, the numerical model was calibrated using the experimental results and then numerical simulations were conducted for rock samples under multimode microwave heating and microwave surface irradiation. The experimental and numerical results indicate that, with increasing cooling time, the surface temperature continuously decreases, and the cooling rate gradually diminishes. Within the same period, the higher the initial surface temperature or the greater the wind speed, the larger the surface temperature drop. Subsequently, the applicable conditions for non-real-time temperature measurement were clarified, and a correction model for the highest surface temperature of rock samples under multimode microwave heating and microwave surface irradiation was established, respectively. The cooling mechanisms of rock surface under the two types of microwave irradiation were also revealed. Finally, for the real-time temperature measurement with infrared sensors, the deviation range between the highest surface temperature and the temperatures at the centers of side and top surfaces of rock samples was provided, with heating by multimode microwave oven in this study as an example. The results show that the temperatures at the centers of side and top surfaces of the sample treated by multimode microwave were 20-30% lower than the highest surface temperature.
引用
收藏
页码:5861 / 5873
页数:13
相关论文
共 50 条
  • [31] Experimental Investigation on Failure Mechanism of Hot Dry Rock under Microwave Irradiation
    He, Leping
    Huang, Chengyi
    Hu, Qijun
    Zeng, Junsen
    Wang, Haoyu
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2023, 23 (04)
  • [32] Remote measurement of the temperature distribution on the surface of solids under high-power laser irradiation
    Zinin, P., V
    Bulatov, K. M.
    Bykov, A. A.
    Mantrova, Yu, V
    Kutuza, I. B.
    PHYSICS-USPEKHI, 2022, 65 (08) : 852 - 863
  • [33] Heating characteristics of igneous rock-forming minerals under microwave irradiation
    Zhao, Q. H.
    Zhao, X. B.
    Zheng, Y. L.
    Li, J. C.
    He, L.
    He, J. L.
    Zou, C. J.
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2020, 135
  • [34] Temperature measurement on tissue surface during laser irradiation
    Surya C. Gnyawali
    Yicho Chen
    Feng Wu
    Kenneth E. Bartels
    James P. Wicksted
    Hong Liu
    Chandan K. Sen
    Wei R. Chen
    Medical & Biological Engineering & Computing, 2008, 46 : 159 - 168
  • [35] Temperature measurement on tissue surface during laser irradiation
    Gnyawali, Surya C.
    Chen, Yicho
    Wu, Feng
    Bartels, Kenneth E.
    Wicksted, James P.
    Liu, Hong
    Sen, Chandan K.
    Chen, Wei R.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (02) : 159 - 168
  • [36] TEMPERATURE-DEPENDENT PERMEABILITY OF LIPOSOMES UNDER MICROWAVE IRRADIATION
    OLLIVON, M
    VERDIER, P
    BIOPHYSICAL JOURNAL, 1985, 47 (02) : A429 - A429
  • [37] MEASUREMENT OF SEA-SURFACE TEMPERATURE BY MICROWAVE RADIOMETER
    VANMELLE, MJ
    MARINE TECHNOLOGY SOCIETY JOURNAL, 1973, 7 (03) : 32 - 40
  • [38] Spatial Patterns of Land Surface Temperature and Their Influencing Factors: A Case Study in Suzhou, China
    Feng, Yongjiu
    Gao, Chen
    Tong, Xiaohua
    Chen, Shurui
    Lei, Zhenkun
    Wang, Jiafeng
    REMOTE SENSING, 2019, 11 (02)
  • [39] Factors influencing resolution of raman distributed temperature measurement system
    Wang Z.
    Ye Z.
    Xia Y.
    Yang C.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (12): : 65 - 73
  • [40] Temperature Measurement Error and Its Influencing Factors of FBG Sensor under Rotor Whirling Conditions Based on Space-Coupled Transmission Method
    Chen Sitong
    Huang Junbin
    Gu Hongcan
    Yao Gaofei
    Xu Dan
    Li Zheyu
    ACTA PHOTONICA SINICA, 2024, 53 (04)