Time-Resolved Laser Speckle Contrast Imaging (TR-LSCI) of Cerebral Blood Flow

被引:2
|
作者
Fathi, Faraneh [1 ]
Mazdeyasna, Siavash [1 ]
Singh, Dara [1 ]
Huang, Chong [1 ]
Mohtasebi, Mehrana [1 ]
Liu, Xuhui [1 ]
Haratbar, Samaneh Rabienia [1 ]
Zhao, Mingjun [1 ]
Chen, Li [2 ]
Ulku, Arin Can [3 ]
Mos, Paul [3 ]
Bruschini, Claudio [3 ]
Charbon, Edoardo [3 ]
Chen, Lei [4 ]
Yu, Guoqiang [1 ]
机构
[1] Univ Kentucky, Dept Biomed Engn, Lexington, KY 40506 USA
[2] Univ Kentucky, Markey Canc Ctr, Biostat & Bioinformat Shared Resource Facil, Lexington, KY 40536 USA
[3] Ecole Polytech Fed Lausanne, Sch Engn, CH-2002 Neuchatel, Switzerland
[4] Univ Kentucky, Spinal Cord & Brain Injury Res Ctr, Dept Physiol, Lexington, KY 40506 USA
基金
瑞士国家科学基金会; 美国国家卫生研究院;
关键词
Logic gates; Cameras; Head; Optical imaging; Speckle; Photonics; Lasers; Biomedical optical imaging; Single-photon avalanche diodes; Adaptive optics; Cerebral blood flow; depth-sensitive; gated single-photon-avalanche-diode camera; laser speckle contrast imaging; parallel computation; time-resolved; SPECTROSCOPY; TOMOGRAPHY; PATHOPHYSIOLOGY; SEPARATION; CORTEX;
D O I
10.1109/TMI.2024.3486084
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To address many of the deficiencies in optical neuroimaging technologies, such as poor tempo-spatial resolution, low penetration depth, contact-based measurement, and time-consuming image reconstruction, a novel, noncontact, portable, time-resolved laser speckle contrast imaging (TR-LSCI) technique has been developed for continuous, fast, and high-resolution 2D mapping of cerebral blood flow (CBF) at different depths of the head. TR-LSCI illuminates the head with picosecond-pulsed, coherent, widefield near-infrared light and synchronizes a fast, high-resolution, gated single-photon avalanche diode camera to selectively collect diffuse photons with longer pathlengths through the head, thus improving the accuracy of CBF measurement in the deep brain. The reconstruction of a CBF map was dramatically expedited by incorporating convolution functions with parallel computations. The performance of TR-LSCI was evaluated using head-simulating phantoms with known properties and in-vivo rodents with varied hemodynamic challenges to the brain. TR-LSCI enabled mapping CBF variations at different depths with a sampling rate of up to 1 Hz and spatial resolutions ranging from tens/hundreds of micrometers on rodent head surfaces to 1-2 millimeters in deep brains. With additional improvements and validation in larger populations against established methods, we anticipate offering a noncontact, fast, high-resolution, portable, and affordable brain imager for fundamental neuroscience research in animals and for translational studies in humans.
引用
收藏
页码:1206 / 1217
页数:12
相关论文
共 50 条
  • [31] Temporal clustering analysis of cerebral blood flow activation maps measured by laser speckle contrast imaging
    Wang, Z
    Luo, QM
    COMPLEX DYNAMICS, FLUCTUATIONS, CHAOS, AND FRACTALS IN BIOMEDICAL PHOTONICS, 2004, 5 (19): : 13 - 21
  • [32] Intraoperative laser speckle contrast imaging with retrospective motion correction for quantitative assessment of cerebral blood flow
    Richards, Lisa M.
    Towle, Erica L.
    Fox, Douglas J., Jr.
    Dunn, Andrew K.
    NEUROPHOTONICS, 2014, 1 (01)
  • [33] A study on an improved laser speckle contrast blood flow imaging methodology
    Han, Guang
    Lu, Jie
    Dong, Xinming
    Li, De
    Yuan, Jixin
    Yang, Qinglong
    Wang, Huiquan
    Chen, Ruijuan
    Wu, Yifan
    Wang, Jinhai
    Min, Xiaolin
    INFRARED PHYSICS & TECHNOLOGY, 2024, 142
  • [34] Laser Speckle Contrast Imaging for Monitoring Changes in Microvascular Blood Flow
    Ambrus, Rikard
    Strandby, Rune B.
    Svendsen, Lars Bo
    Achiam, Michael P.
    Steffensen, John F.
    Svendsen, Morten Bo Sondergaard
    EUROPEAN SURGICAL RESEARCH, 2016, 56 (3-4) : 87 - 96
  • [35] Enhancing Contrast of Laser Speckle Blood Flow Imaging through Polarization
    Cao, Ruixi
    Sang, Xu
    Li, Dong
    Chen, Bin
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (10): : 2736 - 2740
  • [36] Nephron blood flow dynamics measured by laser speckle contrast imaging
    Holstein-Rathlou, Niels-Henrik
    Sosnovtseva, Olga V.
    Pavlov, Alexey N.
    Cupples, William A.
    Sorensen, Charlotte Mehlin
    Marsh, Donald J.
    AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2011, 300 (02) : F319 - F329
  • [37] Real-time quantification of bowel perfusion using Laparoscopic Laser Speckle Contrast Imaging (LSCI) in a porcine model
    Mehrotra, Saloni
    Liu, Yao Z.
    Nwaiwu, Chibueze A.
    Buharin, Vasiliy E.
    Stolyarov, Roman
    Schwaitzberg, Steven D.
    Kalady, Matthew F.
    Kim, Peter C. W.
    BMC SURGERY, 2023, 23 (01)
  • [38] Optical coherence Doppler tomography quantifies laser speckle contrast imaging for blood flow imaging in the rat cerebral cortex
    Luo, Zhongchi
    Wang, Zhenguo
    Yuan, Zhijia
    Dua, Congwu
    Pan, Yingtian
    OPTICS LETTERS, 2008, 33 (10) : 1156 - 1158
  • [39] Lightweight denoising speckle contrast image GAN for real-time denoising of laser speckle imaging of blood flow
    Sang, Xu
    Cao, Ruixi
    Niu, Liushuan
    Chen, Bin
    Li, Dong
    Li, Qiang
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (03): : 1118 - 1142
  • [40] Histogram analysis of laser speckle contrast image for cerebral blood flow monitoring
    Arkady SABDURASHITOV
    Vladislav VLYCHAGOV
    Olga ASINDEEVA
    Oxana VSEMYACHKINAGLUSHKOVSKAYA
    Valery VTUCHIN
    Frontiers of Optoelectronics, 2015, 8 (02) : 187 - 194