Effects of green façade retrofitting on thermal performance and energy efficiency of existing buildings in northern China: An experimental study

被引:0
|
作者
Qi, Sun [1 ]
Utaberta, Nangkula [1 ]
Kiet, Allen Lau Khin [2 ]
Yanfang, Xu [3 ]
Xiyao, Han [4 ]
机构
[1] UCSI Univ Malaysia, Fac Engn Technol & Built Environm, Sch Architecture & Design, Kuala Lumpur, Malaysia
[2] Taylors Univ, Sch Architecture Bldg & Design, Subang Jaya, Malaysia
[3] Shandong Jianzhu Univ, Sch Art, Jinan 250101, Shandong, Peoples R China
[4] Jilin Jianzhu Univ, Sch Int Commun, Changchun 130119, Jilin, Peoples R China
关键词
Green fa & ccedil; ade; Energy saving; Building thermal performance; Plants; Indoor air temperature; FACADES; TEMPERATURE; SYSTEMS; IMPACT; WALLS; CHALLENGES; PLANTS; ROOFS;
D O I
10.1016/j.enbuild.2025.115550
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, vertical greenery systems have gradually entered public attention, and more and more people are beginning to know it. This study aims to explore the impact of green fa & ccedil;ade retrofitting on building thermal performance and building energy consumption under hot summer conditions in northern China and to derive detailed data for future building energy efficiency retrofitting. This article used a comparative experiment to complete this research. Four laboratories of the same structure were constructed in Shandong Province, China. A movable metal frame was installed on the outside of the laboratory, and the green fa & ccedil;ades could be adjusted to direct green fa & ccedil;ades or indirect green fa & ccedil;ades according to the need of the experiment. In addition, two different plants were studied. This study was carried out under two experimental conditions: cooling and no cooling. The experiment was carried out from July to August 2024. According to the data obtained from the experiment, the green fa & ccedil;ade well reduced the surface temperature of the walls around the experimental room and the average temperature level in the room. The most significant temperature drop of 23.1 degrees C was observed on the surface of the external walls of the room with the indirect green fa & ccedil;ade covered with Parthenocissus quinquefolia. The data show that the average temperature in several experimental rooms decreased by 1-5 degrees C. The indirect green fa & ccedil;ade improves the thermal insulation of the building envelope better than the direct green fa & ccedil;ade. In the cooling experiments, the room with indirect green fa & ccedil;ades covered with Parthenocissus quinquefolia has the highest energy-saving rate of 45.75 %. However, the room with direct green fa & ccedil;ades covered with Humulus scandens only has an energy saving rate of 6.43 %.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Numerical study on the winter thermal performance and energy saving potential of thermo-activated PCM composite wall in existing buildings
    Chen, Sarula
    Yang, Yang
    Olomi, Chris
    Zhu, Li
    BUILDING SIMULATION, 2020, 13 (02) : 237 - 256
  • [32] Numerical study on the winter thermal performance and energy saving potential of thermo-activated PCM composite wall in existing buildings
    Sarula Chen
    Yang Yang
    Chris Olomi
    Li Zhu
    Building Simulation, 2020, 13 : 237 - 256
  • [33] Analysis and proposal of implementation effects of heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China in "the 11th Five-Year Plan" period
    Bao, Lingling
    Zhao, Jing
    Zhu, Neng
    ENERGY POLICY, 2012, 45 : 521 - 528
  • [34] Numerical and Experimental Study on Energy Performance of Photovoltaic-Heat Pipe Solar Collector in Northern China
    Chen, Hongbing
    Chen, Xilin
    Chu, Sai
    Zhang, Lei
    Xiong, Yaxuan
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2015, 2015
  • [35] Comparative experimental study on the thermal and energy performance of photovoltaic and green roofs in hot-humid climates
    Zhan, Qiaosheng
    Ma, Yuchan
    Lin, Zhenghao
    Yin, Shi
    Xiao, Yiqiang
    BUILDING AND ENVIRONMENT, 2025, 271
  • [36] Theoretical and experimental study on the performance of a high-efficiency thermodynamic cycle for ocean thermal energy conversion
    Peng, Jingping
    Ge, Yunzheng
    Chen, Fengyun
    Liu, Lei
    Wu, Haoyu
    Liu, Weimin
    RENEWABLE ENERGY, 2022, 185 : 734 - 747
  • [37] Check and evaluation system on heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of china based on multi-index comprehensive evaluation method
    Zhao, Jing
    Wu, Yong
    Zhu, Neng
    ENERGY POLICY, 2009, 37 (06) : 2124 - 2130
  • [38] Individual and Combined Effects of 3D Buildings and Green Spaces on the Urban Thermal Environment: A Case Study in Jinan, China
    Wang, Jiayun
    Meng, Fei
    Lu, Huanhuan
    Lv, Yongqiang
    Jing, Tingting
    ATMOSPHERE, 2023, 14 (06)
  • [39] An experimental study on the thermal and energy performance of self-sustaining green roofs under severe drought conditions in summer
    Zheng, Xing
    Yang, Zhenjing
    Yang, Jiachuan
    Tang, Mingfang
    Feng, Chi
    ENERGY AND BUILDINGS, 2022, 261
  • [40] Effects of thermal energy storage and solar water preheater on the performance of cascade solar still - An experimental study
    Zarei, Mohammad
    Rashidi, Saman
    Rafee, Roohollah
    Li, Guiqiang
    JOURNAL OF ENERGY STORAGE, 2025, 112