Effective ablation settings that predict chronic scar after atrial ablation with HELIOSTAR™ multi-electrode radiofrequency balloon catheter

被引:0
|
作者
Ishidoya, Yuki [1 ,2 ]
Kwan, Eugene [1 ,2 ,3 ]
Hunt, Bram [1 ,2 ,3 ]
Lange, Matthias [1 ,2 ,3 ]
Sharma, Tushar [4 ]
Dosdall, Derek J. [1 ,2 ,3 ,5 ]
Macleod, Rob S. [2 ,3 ]
Kholmovski, Eugene G. [6 ,7 ]
Bunch, T. Jared [1 ]
Ranjan, Ravi [1 ,2 ,3 ]
机构
[1] Univ Utah, Div Cardiovasc Med, 30 N 1900 Rm 4A100, Salt Lake City, UT 84132 USA
[2] Univ Utah, Nora Eccles Harrison Cardiovasc Res & Training Ins, Salt Lake City, UT 84112 USA
[3] Univ Utah, Dept Biomed Engn, Salt Lake City, UT 84112 USA
[4] Biosense Webster Inc, Irvine, CA USA
[5] Univ Utah, Sch Med, Div Cardiothorac Surg, Salt Lake City, UT USA
[6] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
[7] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USA
关键词
Radiofrequency balloon; Magnetic resonance imaging; Catheter ablation; Lesion formation; Chronic scar;
D O I
10.1007/s10840-024-01948-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundRadiofrequency balloon (RFB) ablation (HELIOSTAR (TM), Biosense Webster) has been developed to improve pulmonary vein ablation efficiency over traditional point-by-point RF ablation approaches. We aimed to find effective parameters for RFB ablation that result in chronic scar verified by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR).MethodsA chronic canine model (n = 8) was used to ablate in the superior vena cava (SVC), the right superior and the left inferior pulmonary vein (RSPV and LIPV), and the left atrial appendage (LAA) with a circumferential ablation approach (RF energy was delivered to all electrodes simultaneously) for 20 s or 60 s. The electroanatomical map with the ablation tags was projected onto the 3-month post-ablation LGE-CMR. Tags were divided into two groups depending on whether they correlated with CMR-based scar (ScarTags) or non-scar tissue (Non-ScarTags). The effective parameters for scar formation were estimated by multivariate logistic regression.ResultsThis study assessed 80 lesions in the SVC, 80 lesions in the RSPV, 20 lesions in the LIPV, and 30 lesions in the LAA (168 ScarTags and 42 Non-ScarTags). In the multivariate analysis, two variables were associated with chronic scar formation: temperature of electrode before energy application (odds ratio (OR) 0.805, p = 0.0075) and long RF duration (OR 2.360, p = 0.0218), whereas impedance drop was not associated (OR 0.986, p = 0.373).ConclusionLower temperature of the electrode before ablation and long ablation duration are critical parameters for durable atrial scar formation with RFB ablation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Ablation of atrial fibrillation in the rapid pacing canine model using a multi-electrode loop catheter
    Avitall, B
    Urbonas, A
    Millard, S
    Urboniene, D
    Helms, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (06) : 1733 - 1740
  • [22] One-year follow-up after irrigated multi-electrode radiofrequency ablation of persistent atrial fibrillation
    Pavlovic, Nikola
    Sticherling, Christian
    Knecht, Sven
    Reichlin, Tobias
    Muehl, Aline
    Schaer, Beat
    Osswald, Stefan
    Kuehne, Michael
    EUROPACE, 2016, 18 (01): : 85 - 91
  • [23] Natriuretic peptide levels predict recurrence of atrial fibrillation after radiofrequency catheter ablation
    den Uijl, Dennis W.
    Delgado, Victoria
    Tops, Laurens F.
    Ng, Arnold C. T.
    Boersma, Eric
    Trines, Serge A.
    Zeppenfeld, Katja
    Schalij, Martin J.
    van der Laarse, Arnoud
    Bax, Jeroen J.
    AMERICAN HEART JOURNAL, 2011, 161 (01) : 197 - 203
  • [24] Left atrial function and scar after catheter ablation of atrial fibrillation
    Wylie, John V., Jr.
    Peters, Dana C.
    Essebag, Vidal
    Manning, Warren J.
    Josephson, Mark E.
    Hauser, Thomas H.
    HEART RHYTHM, 2008, 5 (05) : 656 - 662
  • [25] Effective contact and outcome after pulmonary vein isolation in novel circular multi-electrode atrial fibrillation ablation
    Gal, P.
    Buist, T. J.
    Smit, J. J. J.
    Adiyaman, A.
    Misier, A. R. Ramdat
    Delnoy, P. P. H. M.
    Elvan, A.
    NETHERLANDS HEART JOURNAL, 2017, 25 (01) : 16 - 23
  • [26] Long-term outcomes (>2 years) of atrial fibrillation ablation using a multi-electrode ablation catheter in patients with paroxysmal atrial fibrillation
    Khang-Li Looi
    Parag Gajendragadkar
    Tamer Taha
    Maros Elsik
    Elizabeth Scully
    Patrick Heck
    Simon Fynn
    Munmohan Virdee
    David Begley
    Journal of Interventional Cardiac Electrophysiology, 2013, 36 : 61 - 69
  • [27] Effective contact and outcome after pulmonary vein isolation in novel circular multi-electrode atrial fibrillation ablation
    P. Gal
    T. J. Buist
    J. J. J. Smit
    A. Adiyaman
    A. R. Ramdat Misier
    P. P. H. M. Delnoy
    A. Elvan
    Netherlands Heart Journal, 2017, 25 : 16 - 23
  • [28] Characterization of reconduction of pulmonary veins after pulmonary vein isolation using a multi-electrode duty cycled radiofrequency ablation catheter
    Langbein, A.
    Karolyi, L.
    Weinmann, T.
    Scharfe, F.
    Spitzer, S. G.
    EUROPEAN HEART JOURNAL, 2015, 36 : 575 - 575
  • [29] Atrial fibrillation occurrence after radiofrequency catheter ablation for atrial flutter
    Marquie, C
    Gonin, X
    Klug, D
    Degeeter, G
    Brigadeau, F
    Kouakam, C
    Lacroix, D
    Kacet, S
    EUROPEAN HEART JOURNAL, 2003, 24 : 598 - 598
  • [30] Pulmonary vein isolation to treat paroxysmal atrial fibrillation: conventional versus multi-electrode radiofrequency ablation
    Beukema, Rypko J.
    Elvan, Arif
    Smit, Jaap Jan J.
    Delnoy, Peter Paul H. M.
    Misier, Anand R. Ramdat
    Reddy, Vivek
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (02) : 143 - 152