Analysis of factors influencing contact arc erosion under capacitive inrush currents in high-voltage DC relays

被引:0
|
作者
Wang, Haitao [1 ,2 ]
Li, Shuge [1 ]
Lin, Zhen [3 ]
Li, Wei [3 ]
Liu, Qinneng [3 ]
Jiang, Wenli [3 ]
机构
[1] Hebei Univ Technol, State Key Lab Intelligent Power Distribut Equipmen, Tianjin 300401, Peoples R China
[2] Hebei Univ Technol, Prov & Ministerial Coconstruct Collaborat Innovat, Tianjin 300401, Peoples R China
[3] Contemporary Amperex Technol Co Ltd, Ningde 352100, Fujian, Peoples R China
关键词
TRANSVERSE MAGNETIC-FIELDS; PHYSICAL-PROPERTIES; PLASMA BEHAVIOR; SIMULATION; PRESSURE; METAL; HYDROGEN; SURFACE; RANGE; AIR;
D O I
10.1063/5.0255511
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
High-voltage DC relays are widely used in electric vehicles. Due to the presence of capacitive elements in the circuit, a large inrush current occurs at the moment of power-on, resulting in arcing between the relay contacts. This process erodes the contact surfaces, adversely affecting the relay's performance and lifespan. Although improvements such as pre-charged circuits are available, capacitive power-on arc erosion remains common. Therefore, this paper presents a two-dimensional simulation model for high-voltage DC relays, based on magnetohydrodynamics. The model incorporates two arc extinguishing methods: high-voltage arc extinguishing medium and magnetic blowout arc extinction. The simulation model is used to examine the dynamic process of arc erosion and the extent of contact erosion. Subsequently, the study selected eight operating conditions for simulations and experiments, then conducted a correlation analysis between the areas of contact melt pools post-simulation and the areas of contact erosion post-experiment. This confirmed the consistency of trends between the simulation results and experimental outcomes. Based on this, the study analyzes the effects of voltage, current, and capacitance on arc erosion, summarizing the physical processes and principles of arc erosion under different factors, and further examines the mechanisms of these factors from perspectives such as maximum instantaneous power and arc energy. Finally, the results indicate that current has the most significant impact on contact arc erosion. The simulation model has broad applicability and provides practical significance for analyzing arc erosion under capacitive inrush currents in high-voltage DC relays, significantly improving research efficiency.
引用
收藏
页数:15
相关论文
共 22 条
  • [1] Contact Erosion at High Currents in High-Voltage Gas Circuit Breakers-Part II: Assessment of Energy Balance of Arc-Electrode
    Zhou, Yannan
    Humphries, James E.
    Spencer, Joseph W.
    Yan, Joseph D.
    Wang, Zhixiang
    Jones, Gordon R.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2025, 40 (02) : 786 - 796
  • [2] Study on magnetically blown arc characteristics and the resulting contact erosion mechanisms of high-power DC relays
    Hou, Guobin
    Zhang, Dandan
    Li, Zhenbiao
    Pan, Wenwu
    Wan, Zhiyu
    Ye, Xuebin
    Huang, Ziheng
    You, Yuwei
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2023, 56 (21)
  • [3] Comparative Analysis of Active Inrush Current Limiter for High-Voltage DC Power Supply System
    Lee, Eun-Ju
    Ahn, Jung-Hoon
    Shin, Seung-Min
    Lee, Byoung-Kuk
    2012 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2012, : 1256 - 1260
  • [4] Characterisation of surface morphology of high voltage DC relay contacts under arc erosion
    Wang, Haitao
    Yang, Tao
    Wu, Kai
    Li, Wei
    Lin, Zhen
    Liu, Qinneng
    Jiang, Wenli
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2024, 12 (04):
  • [5] Theoretical Analysis and Calculation of Arc Contact Erosion of High Voltage Circuit Breaker
    Chen, Gong
    Cheng, Zhuang
    Duan, Tao
    Zeng, Weiwen
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 189 - 193
  • [6] Analysis of leakage currents in photovoltaic modules under high-voltage bias in the field
    del Cueto, JA
    McMahon, TJ
    PROGRESS IN PHOTOVOLTAICS, 2002, 10 (01): : 15 - 28
  • [7] Contact Erosion at High Currents in High-Voltage Gas Circuit Breakers-Part I: Experimental Research and Material Testing
    Zhou, Yannan
    Humphries, James E.
    Spencer, Joseph W.
    Yan, Joseph D.
    Wang, Zhixiang
    Jones, Gordon R.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2025, 40 (02) : 776 - 785
  • [8] Analysis of factors influencing limb amputation in high-voltage electrically injured patients
    Hsueh, Yuan-Yu
    Chen, Chung-Lin
    Pan, Shin-Chen
    BURNS, 2011, 37 (04) : 673 - 677
  • [9] Analysis of influencing factors on buffer layer discharge for high-voltage XLPE cable
    Wu, Zhiheng
    Lai, Qingbo
    Zhou, Wenqing
    Liu, Xiaodong
    Chen, Jie
    Hu, Libin
    Hao, Yanpeng
    Liu, Gang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (20) : 4142 - 4157
  • [10] Thermal Shock Effect Analysis of CuW Contact under High Voltage Arc
    Wang Yanlong
    Liang Shuhua
    Yang Xiaohong
    Zou Juntao
    Xiao Peng
    RARE METAL MATERIALS AND ENGINEERING, 2012, 41 (02) : 266 - 270