Development of a biocompatible radiotherapy spacer using 3D printing and microcellular foaming process for enhanced prostate cancer treatment

被引:1
|
作者
Lim, DongHwan [1 ]
Yoon, DoKun [2 ]
Kim, JaeHoo [3 ]
Sung, KiHoon [4 ]
Choi, YoungEun [4 ]
Sheen, HeeSoon [3 ]
Shin, Han-Back [4 ]
Cha, Sung Woon [1 ]
机构
[1] Yonsei Univ, Sch Mech Engn, Seoul, South Korea
[2] Gachon Univ, Gil Med Ctr, Dept Radiat Oncol, Incheon, South Korea
[3] Sungkyunkwan Univ, Samsung Adv Inst Hlth Sci & Technol, Dept Hlth Sci & Technol, Seoul, South Korea
[4] Gachon Univ, Gil Med Ctr, Dept Radiat Oncol, Incheon, South Korea
基金
新加坡国家研究基金会;
关键词
3D printing; Prostate cancer treatment; Radiotherapy spacer; Microcellular foaming process; Biodegradable polymer; RADIATION-THERAPY; STERILIZATION; SCAFFOLDS; TOXICITY; HYDROGEL; BEHAVIOR; DEVICES; PCL;
D O I
10.36922/ijb.4252
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, a new active spacer was developed using three-dimensional (3D) printing technology and microcellular foaming process to overcome the limitations of current spacers used in prostate cancer treatment. In prostate cancer treatment, a spacer is inserted between the prostate and rectum to increase the distance between the two organs so as to reduce the radiation dose to the rectum. Radiotherapy spacer is widely used in particle therapy, such as proton and carbon beams, and X-ray radiation therapies, including intensity-modulated radiotherapy and stereotactic body radiation therapy. However, existing spacers have been reported to cause significant side effects. Therefore, this study introduces a 3D printing technique using polycaprolactone to develop a spacer that provides customized treatment and minimizes side effects. This technique utilizes the volume expansion that occurs when a 3D spacer printed to fit a patient's organs undergoes foaming through a supercritical carbon dioxide (scCO2)-assisted 2 )-assisted microcellular foaming process. Additionally, the use of scCO2 2 allows simultaneous gas absorption and sterilization, thereby reducing the number of process steps. This study confirms the potential of the newly developed spacer to provide effective and safe radiotherapy for prostate cancer, reduce patient discomfort, and minimize rectal side effects during radiation treatment.
引用
收藏
页码:477 / 486
页数:10
相关论文
共 50 条
  • [21] 3D probability distribution of treatment targets: A new way to define 3D organ motion for prostate cancer radiotherapy
    Patel, CB
    Wang, C
    Zhang, J
    Dong, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S523 - S523
  • [22] In Situ Foam 3D Printing of Microcellular Structures Using Material Extrusion Additive Manufacturing
    Kalia, Karun
    Francoeur, Benjamin
    Amirkhizi, Alireza
    Ameli, Amir
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (19) : 22454 - 22465
  • [23] Evaluation of Thermal Properties of 3D Spacer Technical Materials in Cold Environments using 3D Printing Technology
    Eom, Ran-i
    Lee, Hyojeong
    Lee, Yejin
    POLYMERS, 2019, 11 (09)
  • [24] Assessment of the Second Cancer Risk after Prostate Cancer Treatment: Comparison of 3D Conformal Radiotherapy and Intensity Modulated Radiotherapy
    Hassana I.M.
    Attalla E.M.
    El-Gohary M.I.
    Iranian Journal of Medical Physics, 2022, 19 (04) : 222 - 233
  • [25] Custom Designed Orthodontic Attachment Manufactured Using a Biocompatible 3D Printing Material
    Nagib, Riham
    Szuhanek, Camelia
    Moldoveanu, Bogdan
    Negrutiu, Meda Lavinia
    Sinescu, Cosmin
    Brad, Silviu
    MATERIALE PLASTICE, 2017, 54 (04) : 757 - 758
  • [26] Radiobiological model comparison of 3D conformal radiotherapy and IMRT plans for the treatment of prostate cancer
    Deb, P.
    Fielding, A.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (02) : 51 - 61
  • [27] Radiobiological model comparison of 3D conformal radiotherapy and IMRT plans for the treatment of prostate cancer
    P. Deb
    A. Fielding
    Australasian Physics & Engineering Sciences in Medicine, 2009, 32 : 51 - 61
  • [28] A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM
    Adam, D.
    Suditu, M. D.
    Popa, R.
    Ion, R. E.
    Ciocaltei, V.
    ROMANIAN REPORTS IN PHYSICS, 2014, 66 (02) : 394 - 400
  • [29] Materials Testing for the Development of Biocompatible Devices through Vat-Polymerization 3D Printing
    Gonzalez, Gustavo
    Baruffaldi, Desiree
    Martinengo, Cinzia
    Angelini, Angelo
    Chiappone, Annalisa
    Roppolo, Ignazio
    Pirri, Candido Fabrizio
    Frascella, Francesca
    NANOMATERIALS, 2020, 10 (09) : 1 - 13
  • [30] A Novel Immobilization Method for the Treatment of Head and Neck Cancer Using 3D Printing
    Szewczyk, Christopher
    Liao, Yixiang
    Al-Khudari, Samer
    Jelinek, Michael J.
    Tatebe, Ken
    PRACTICAL RADIATION ONCOLOGY, 2024, 14 (01) : 20 - 23