Formation of MoS2/HA ceramic film on plasma electrolytic oxidized Ti-6Al-4V using mechanically synthesized method: Enhancing surface characteristics and biocompatibility for bio-implant

被引:0
|
作者
Nisar, Sidra Sadaf
Choe, Han-Cheol [1 ]
机构
[1] Chosun Univ, Coll Dent, Dept Dent Mat, Adv Funct Surface & Biomat Res Lab, Gwangju, South Korea
基金
新加坡国家研究基金会;
关键词
Mechanically synthesized (MS) film; MoS2-HA ceramics; Plasma electrolytic oxidation; Surface characteristics; Biocompatibility; HYDROXYAPATITE COATINGS; COMPOSITE COATINGS; PERFORMANCE; DISSOLUTION; GROWTH;
D O I
10.1016/j.ceramint.2024.11.455
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This study inspected the impact of mechanically synthesized molybdenum disulfide (MoS2) and hydroxyapatite (HA) coatings on plasma electrolytic oxidation (PEO) treated Ti-6Al-4V alloy. For the formation of MoS2-HA ceramic, varying compositions of MoS2 and HA (0, 3, 5, and 7 g) were mechanically synthesized (MS) for 6 h in a mechanical mixer containing PEO-treated Ti-6Al-4V alloy. The research aimed to evaluate the influence of these coatings on surface properties and bioactivity. The combined use of MoS2 and HA leverages the unique properties of both materials: HA provides excellent biocompatibility and corrosion resistance, while MoS2 enhances mechanical properties and scratch resistance. Surface characterization techniques, FESEM, XRD, and FTIR were employed to analyze the MS film's morphology, composition, and surface properties. Mechanical properties of ceramic were assessed through nanoindentation and scratch tester. PDP and EIS tests were conducted to evaluate the corrosion resistance of the ceramic. Moreover, the bioactivity of the ceramic was assessed through immersion tests in SBF, examining the formation and growth of apatite layers on the surface. EIS was also performed after SBF immersion. Results indicated that the MoS2-HA coatings significantly enhance the surface properties, corrosion resistance, and bioactivity of the PEO-treated Ti-6Al-4V alloy, with the optimal composition determined to be the sample of 3g MoS2 and 7g HA.
引用
收藏
页码:4806 / 4827
页数:22
相关论文
共 45 条
  • [31] Surface Observation of Plasma Electrolytic Oxidation-Treated Ti-6Al-4V Alloy After 2-Step Nano-Mesh Formation
    Lim, Sang-Gyu
    Choe, Han-Cheol
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (09) : 5755 - 5758
  • [32] Pore Shape Changes and Apatite Formation on Zn and Si Ion-Doped HA Films of Ti-6Al-4V After Plasma Electrolytic Oxidation Treatment
    Hwang, In-Jo
    Choe, Han-Cheol
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2018, 18 (02) : 1442 - 1444
  • [33] Comprehensive evaluation of MWCNT/HAp and Cu-functionalized MWCNT/HAp coatings on Ti6Al4V implants: Enhancing surface characteristics and biocompatibility via plasma electrolytic oxidation
    Logesh, Mahendran
    Ahn, Sang-Gun
    Choe, Han-Cheol
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2024, 33 : 7620 - 7644
  • [34] Obtaining Hydroxyapatite (HA) by Sol-Gel Method on Ti6Al4V Alloys Aiming the Implant's Surface Bio-Functionalization
    Stirbu, Ionut
    Vizureanu, Petrica
    Ratoi, Mihaela
    Cimpoesu, Ramona
    2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,
  • [35] Effect of Arc Plasma Sintering Process on Formation of TiO2 Surface Layer for Ti-6Al-4V Applications
    Supriadi, S.
    Gatot, M. P.
    Roseno, F. A.
    Annur, D.
    Suharno, B.
    Dimyati, A.
    PROCEEDINGS OF THE 3RD INTERNATIONAL SEMINAR ON METALLURGY AND MATERIALS (ISMM 2019): EXPLORING NEW INNOVATION IN METALLURGY AND MATERIALS, 2020, 2232
  • [36] In-vitro biocompatibility, antibacterial activity, and corrosion resistance of HA-TiO 2 /ZnO coating fabricated by plasma electrolytic oxidation on Ti6Al4V
    Fathyunes, Leila
    Hosseini, Milad
    Khalil-Allafi, Jafar
    MATERIALS TODAY COMMUNICATIONS, 2024, 40
  • [37] Enhanced Friction and Wear Properties of TiN/MoS2 Composite Coating on the Surface of Plasma Nitrided Ti6Al4V Alloy
    Li, Hongyu
    Le, Kai
    Wang, Ganggang
    Ren, Zhenghao
    Liu, Yuzhen
    Yang, Zhenglong
    Zheng, Liwei
    Xu, Shusheng
    LUBRICANTS, 2025, 13 (01)
  • [38] Fabrication of spark plasma sintered porous Ti-6Al-4V using PCA-added space holder method for bone implant materials
    Lantang, Yorina S. F.
    Kobayashi, Equo
    Sato, Tatsuo
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 2693 - 2701
  • [39] One-step preparation of TiO2/MoS2 composite coating on Ti6Al4V alloy by plasma electrolytic oxidation and its tribological properties
    Mu, Ming
    Liang, Jun
    Zhou, Xinjian
    Xiao, Qian
    SURFACE & COATINGS TECHNOLOGY, 2013, 214 : 124 - 130
  • [40] Crystallinity, surface morphology, and chemical composition of the recast layer and rutile-TiO2 formation on Ti-6Al-4V ELI by wire-EDM to enhance biocompatibility
    Saadman Sakib Rahman
    Md. Zurais Ibne Ashraf
    M. S. Bashar
    M. Kamruzzaman
    A. K. M. Nurul Amin
    M. M. Hossain
    The International Journal of Advanced Manufacturing Technology, 2017, 93 : 3285 - 3296