Urgent endovascular repair of juxtarenal/pararenal aneurysm by off-the-shelf multibranched endograft

被引:1
|
作者
Gallitto, Enrico [1 ,2 ,15 ]
Faggioli, Gianluca [1 ,2 ]
Austermann, Martin [3 ]
Koelbel, Tilo [4 ]
Tsilimparis, Nikolas [5 ]
Dias, Nuno [6 ]
Melissano, Germano [7 ]
Simonte, Gioele [8 ]
Katsargyris, Athanasios [9 ]
Oikonomou, Kyriakos [10 ,11 ]
Mani, Kevin [12 ]
Pedro, Luis Mendes [13 ]
Cecere, Fabrizio [1 ]
Haulon, Stephan [14 ]
Gargiulo, Mauro [1 ,2 ]
机构
[1] Univ Bologna DIMEC, Vasc Surg, Bologna, Italy
[2] IRCCS, Univ Hosp Policlin S Orsola, Vasc Surg Unit, Bologna, Italy
[3] Bonifatius Hosp, Dept Vasc & Endovasc Surg, Lingen, Germany
[4] Univ Heart & Vasc Ctr UKE, German Aort Ctr, Dept Vasc Med, Hamburg, Germany
[5] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Vasc Surg, Munich, Germany
[6] Skane Univ Hosp, Vasc Ctr, Dept Thorac Surg & Vasc Dis, Malmo, Sweden
[7] Univ Vita Salute San Raffaele, Div Vasc Surg, Sci Inst H San Raffaele, Milan, Italy
[8] S Maria Misericordia Univ Hosp, Vasc & Endovascular Surg Unit, Vasc & Endovasc Surg Unit, Perugia, Italy
[9] Natl & Kapodistrian Univ Athens, Vasc Surg, Athens, Greece
[10] Univ Hosp, Vasc & Endovasc Surg, Frankfurt, Germany
[11] Wolfgang Goethe Univ Frankfurt, Frankfurt, Germany
[12] Uppsala Univ, Dept Surg Sci, Div Vasc Surg, Uppsala, Sweden
[13] Univ Lisbon, Ctr Hosp Univ Lisboa Norte, Ctr Cardiovasc, Dept Vasc Surg ,Fac Med, Lisbon, Portugal
[14] Marie Lannelongue Hosp, Dept Thorac & Vasc Surg, Paris, France
[15] IRCCS, Dept Vasc Surg, IRCCS St Orsola Malpighi Massarenti St 9th, Bologna, Italy
关键词
Urgent endovascular repair; Juxta/Pararenal aneurysm; Off the shelf endograft; Branched endograft; Thoracoabdominal; THORACOABDOMINAL ANEURYSM; FENESTRATED ENDOGRAFTS; AORTIC-ANEURYSMS; STENT GRAFT; OUTCOMES; MORTALITY; RUPTURE; OPTION;
D O I
10.1016/j.jvs.2024.07.005
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To report outcomes of urgent juxtarenal/pararenal aneurysms (J/P-AAAs) managed by off-the-shelf multibranched thoracoabdominal endografts (Cook, T-branch). Methods: In this observational, multicenter, retrospective study, patients with J/P-AAAs treated by urgent endovascular repair by T-branch in 23 European aortic centers, from 2013 to 2023, were analyzed. Contained J/P-AAAs rupture, presence of related symptoms, and aneurysm diameter of >70 mm were considered as indication for urgent repair. Technical success (TS), spinal cord ischemia (SCI), and 30-day/hospital mortality were assessed as early outcomes. Survival, freedom from reinterventions, and target artery instability (TAI) were evaluated during follow-up. Results: Overall, 197 patients (J-AAAs, n = 64 [33%]; P-AAAs, n = 95 [48%]; previous failed endovascular aneurysm repair (EVAR), n = 38 [19%]) were analyzed. The mean age and aneurysm diameter was 75 +/- 8 years and 76 +/- 4 mm, respectively. The American Society of Anesthesiologists score was 3 and 4 in 118 (60%) and 79 (40%) patients. Rupture, symptoms, and diameter of >70 mm were present in 51 (26%), 110 (56%), and 53 (27%) patients, respectively. An adjunctive proximal thoracic endograft was used in 28 cases (14%). The mean aortic coverage between the upper portion of the endograft and the lowest renal artery was 154 +/- 49 mm. Single-stage repair and cerebrospinal fluid drainage were reported in 144 (73%) and 53 (27%) cases, respectively. TS was achieved in 182 (92%) cases (rupture, 84% vs no rupture, 95%; P = .02). Failures consist of TA loss (11 [6%]: renal artery, 9; celiac trunk, 2), type I to III endoleaks (2 [1%]), and 24-h mortality (2 [1%]). Rupture was a risk factor for technical failure (P = .02; odds ratio [OR], 3.8; 95% confidence interval [CI], 1.1-12.1). Overall, 15 patients (8%) had persistent SCI (rupture, 14% vs no rupture, 5%) with 11 (6%) , of paraplegia (rupture, 10% vs no rupture, 5%; P = .001). Rupture (P = .04; OR, 3.1; 95% CI, 1.1-8.9) and adjunctive proximal thoracic endograft (P = .01; OR, 4.1; 95% CI, 1.3-12.9) were risk-factors for SCI. Twenty-two patients (11%) died within 30 days or during a prolonged hospitalization. Previous failed EVAR (P = .04; OR, 3.6; 95% CI, 1.1-12.3), paraplegia (P < .001; OR, 9.9; 95% CI, 1.6-62.2) and postoperative mesenteric complications (P = .03; OR, 10.4; 95% CI, 1.2-93.3), as well as cardiac (P = .03; OR, 8.2; 95% CI, 2.0-33.0) and respiratory (P < .001; OR, 10.1; 95% CI, 2.9-35.2) morbidities were associated with 30-day/hospital mortality. The mean follow-up was 19 +/- 5 months. The estimated 3-year survival and freedom from reinterventions was 58% and 77%, respectively. TAI occurred in 27 patients (14%) (occlusion, 15; endoleak, 14) with an estimated 3-year freedom from TAI of 72%. Conclusions: Urgent repair of J/P-AAAs by T-branch is feasible and effective with satisfactory TS and 30-day/hospital mortality in high-risk patients. However, extensive aortic coverage is necessary, leading to a non-negligible SCI rate, especially in case of aortic rupture or when adjunctive thoracic endografts are necessary. Previous failed EVAR and postoperative mesenteric complications, as well as cardiac and respiratory morbidities were associated with 30-day/hospital mortality and should be subjected to more research for the purposes of improving outcomes.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Outcomes of off-the-shelf preloaded inner branch device for urgent endovascular thoraco-abdominal aortic repair in the ItaliaN Branched Registry of E-nside EnDograft
    Piazza, Michele
    Squizzato, Francesco
    Ferri, Michelangelo
    Pratesi, Giovanni
    Gatta, Emanuele
    Orrico, Matteo
    Giudice, Rocco
    Antonello, Michele
    JOURNAL OF VASCULAR SURGERY, 2024, 80 (05)
  • [42] "Off-the-shelf" devices for complex aortic aneurysm repair DISCUSSION
    Beck, Adam W.
    Farber, Mark A.
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (03) : 583 - 584
  • [43] Outcomes of multibranched off-the-shelf stent graft in elective and urgent/emergent repair of complex aortic aneurysms with narrow internal aortic lumen
    Ferrer, Ciro
    Orrico, Matteo
    Spataro, Claudio
    Coscarella, Carlo
    Ronchey, Sonia
    Marino, Mario
    Giudice, Rocco
    Mangialardi, Nicola
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (02) : 326 - 334
  • [44] Endovascular aortic repair of pararenal aortic aneurysm with multibranched stent-graft: First successful experience in Turkey
    Canyigit, Murat
    Uguz, Emrah
    Hidiroglu, Mete
    Sener, Erol
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 23 (03): : 561 - 565
  • [45] Outcomes of off-the-shelf multibranched stent grafts with intentional occlusion of directional branches using endovascular plugs during endovascular repair of complex aortic aneurysms
    Tenorio, Emanuel R.
    Oderich, Gustavo S.
    Kolbel, Tilo
    Gargiulo, Mauro
    Timaran, Carlos H.
    Bertoglio, Luca
    Modarai, Bijan
    Jama, Katarzyna
    Eleshra, Ahmed
    Lima, Guilherme B. B.
    Scott, Carla
    Chiesa, Roberto
    Jakimowicz, Tomasz
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (04) : 1142 - +
  • [46] Fenestrated endovascular repair for juxtarenal aortic aneurysm
    Scurr, J. R. H.
    Brennan, J. A.
    Gilling-Smith, G. L.
    Harris, P. L.
    Vallabhaneni, S. R.
    McWilliams, R. G.
    BRITISH JOURNAL OF SURGERY, 2008, 95 (03) : 326 - 332
  • [47] Off-the-Shelf, Hybrid, Innominate Chimney Thoracic Endovascular Aneurysm Repair for Treatment of Mycotic Thoracic Aortic Aneurysm: A Case Report
    Dayna, Sim Pei Yin
    Peng, Nick Ng Zhi
    Shaun, Lee Qingwei
    VASCULAR SPECIALIST INTERNATIONAL, 2024, 40
  • [48] Stent Graft Modification to Preserve Intercostal Arteries Using Thoracoabdominal Off-the-Shelf Multibranched (t-Branch) Endograft
    Ferreira, Marcelo
    Mannarino, Matheus
    Cunha, Rodrigo
    Ferreira, Diego
    Capotorto, Luis Fernando
    Oderich, Gustavo S.
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (03) : 382 - 387
  • [49] Zenith p-Branch Fenestrated Endovascular Graft: How Close "Off-the-Shelf " Repair for Asian Patients with Juxtarenal Aortic Aneurysms?
    Ou, Jiale
    Cheng, Stephen W. K.
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (02) : 540 - 540
  • [50] Endovascular Thoracoabdominal Aortic Aneurysm Repair With t-Branch Off-the-Shelf Stent Graft: An Illustrated Video
    Mendes, Bernardo C.
    Oderich, Gustavo S.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (06) : 42S - 42S