Outcomes of leadless pacemaker implantation in the United States based on sex

被引:0
|
作者
Khan, Muhammad Zia [1 ]
Alyami, Bandar [1 ]
Alruwaili, Waleed [1 ]
Nguyen, Amanda T. [2 ]
Mendez, Melody [2 ]
Leon, William E. [2 ]
Devera, Justin [2 ]
Hayat, Hafiz Muhammad Sohaib [2 ]
Naveed, Abdullah [3 ]
Asad, Zain Ul Abideen [4 ]
Agarwal, Siddharth [4 ]
Balla, Sudarshan [1 ]
Darden, Douglas [5 ]
Munir, Muhammad Bilal [6 ]
机构
[1] West Virginia Univ, Div Cardiol, Heart & Vasc Inst, Morgantown, WV USA
[2] Univ Calif Davis, Div Cardiol, Sacramento, CA 95817 USA
[3] Dow Med Coll, Dept Med, Karachi, Sindh, Pakistan
[4] Univ Oklahoma, Div Cardiol, Oklahoma City, OK USA
[5] Kansas City Heart Rhythm Inst, Div Cardiol, Overland Pk, KS USA
[6] Univ Calif Davis, Div Cardiol, Sect Electrophysiol, Sacramento, CA 95616 USA
关键词
Leadless; Pacemaker; Women; Outcomes; Complications; Mortality; GENDER-DIFFERENCES; COMPLICATIONS;
D O I
10.1007/s10840-024-01936-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To determine differences in baseline characteristics and outcomes of leadless pacemaker implantation based on sex. Methods For the purpose of this study, data were extracted from the National Inpatient Sample database for years 2016-2020. The study group was then stratified based on sex. Baseline characteristics and in-hospital outcomes including complications were then analyzed in each group. Multivariable logistic regression models were created to analyze the association of sex with important outcomes of mortality, major complications (defined as pericardial effusion requiring intervention and any vascular complication), prolonged length of stay (defined as > 6 days), and increased cost of hospitalization (defined as median cost > 34,098$) after leadless pacemaker implantation. Results A total of 29,000 leadless pacemakers (n in women = 12,960, 44.7%) were implanted during our study period. Women were found to have an increased burden of co-morbidities as compared to men. In the adjusted analysis, the likelihood of mortality (aOR 1.27, 95% CI 1.14-1.43), major complications (aOR 1.07, 95% CI 0.98-1.18), prolonged length of stay (aOR 1.09, 95% CI 1.04-1.15), and increased hospitalization cost (aOR 1.14, 95% CI 1.08-1.20) were higher in women as compared to men after leadless pacemaker implantation. Conclusion Important and significant differences exist in leadless pacemaker implantation in women as compared to men. These findings highlight the need for evaluating etiologies behind such differences with a goal of improving outcomes in all patients after leadless pacemaker implantation.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Efficacy and safety of leadless pacemaker implantation in octogenarians
    Hofer, Daniel
    Regoli, Francois
    Saguner, Ardan M.
    Conte, Giulio
    Jelisejevas, Julius
    Luce Caputo, Maria
    Graup, Vera
    Gauthier, LorenzoGrazioli
    Gasperetti, Alessio
    Steffel, Jan
    Auricchio, Angelo
    Breitenstein, Alexander
    CARDIOLOGY, 2023, 148 (05) : 441 - 447
  • [32] Safety of leadless pacemaker implantation in the very elderly
    Pagan, Eric
    Gabriels, James
    Khodak, Alexander
    Chang, David
    Beldner, Stuart
    Epstein, Laurence M.
    Willner, Jonathan
    HEART RHYTHM, 2020, 17 (12) : 2023 - 2028
  • [33] TRANSSUBCLAVIAN IMPLANTATION OF THE AVEIR LEADLESS PACEMAKER SYSTEM
    Balanescu, Dinu Valentin
    Welle, Garrett A.
    Asirvatham, Samuel J.
    Friedman, Paul A.
    Mulpuru, Siva K.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 2962 - 2962
  • [34] Mortality After Micra Leadless Pacemaker Implantation
    Kamath, Akshay R.
    Heard, Brittney Z.
    Darby, Andrew E.
    Malhotra, Rohit
    Mangrum, James M.
    Bilchick, Kenneth C.
    Mason, Pamela K.
    Ferguson, John D.
    Mehta, Nishaki K.
    CIRCULATION, 2018, 138
  • [35] Leadless pacemaker implantation complications and the denominator problem
    Zeitler, Emily P.
    Crossley, George H.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (02) : 160 - 163
  • [36] Initial experience with leadless pacemaker implantation in Argentina
    Aguinaga, Luis
    Arana, Walter Bernal
    Bravo, Alejandro
    Sialle, Marcela
    Aguinaga, Lucia
    Quintana, Roberto
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2022, 51 (03):
  • [37] Echocardiogram- Guided Leadless Pacemaker Implantation
    Bhardwaj, Rahul
    Kewcharoen, Jakrin
    Contractor, Tahmeed
    Nayak, Srishti
    Ai, Saif
    Kim, Uoo
    Mandapati, Ravi
    Garg, Jalaj
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (12) : 1581 - 1582
  • [38] Epicardial implantation of a leadless pacemaker in a lamb model
    Backhoff, David
    Betz, Teresa
    Eildermann, Katja
    Paul, Thomas
    Zenker, Dieter
    Bonner, Matthew
    Krause, Ulrich
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (12): : 1481 - 1485
  • [39] Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
    Reddy, Vivek Y.
    Exner, Derek V.
    Cantillon, Daniel J.
    Doshi, Rahul
    Bunch, T. Jared
    Tomassoni, Gery F.
    Friedman, Paul A.
    Estes, N. A. Mark, III
    Ip, John
    Niazi, Imran
    Plunkitt, Kenneth
    Banker, Rajesh
    Porterfield, James
    Ip, James E.
    Dukkipati, Srinivas R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (12): : 1125 - 1135
  • [40] Leadless pacemaker implantation. Case report
    Pardo, Jose G.
    Lira, Gonzalo L. P.
    Marrero, Roberto M.
    Egger, Jorge Z.
    Jofre, Maria Lorena S. M.
    REVISTA MEDICA DE CHILE, 2022, 150 (08) : 1108 - 1114