Replacing manual planning with automatic iterative planning for locally advanced rectal cancer VMAT treatment

被引:0
|
作者
Liu, Jiacheng [1 ]
Wang, Ruoxi [1 ]
Wang, Qingying [2 ]
Yao, Kaining [1 ]
Wang, Meijiao [1 ]
Du, Yi [1 ,2 ]
Yue, Haizhen [1 ]
Wu, Hao [1 ,2 ]
机构
[1] Peking Univ, Dept Radiat Oncol, Key Lab Carcinogenesis & Translat Res, Minist Educ Beijing,Canc Hosp & Inst, 52 Fucheng Rd, Beijing 100142, Peoples R China
[2] Peking Univ, Inst Med Technol, Hlth Sci Ctr, Beijing, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
automatic iterative planning; locally advanced rectal cancer; volumetric-modulated arc therapy; INTENSITY-MODULATED RADIOTHERAPY; HEMATOLOGIC TOXICITY; RADIATION-THERAPY; OPTIMIZATION; CHEMORADIATION; VALIDATION; BOWEL; PLANS; IMRT; FMEA;
D O I
10.1002/acm2.14552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and implement a fully automatic iterative planning (AIP) system in the clinical practice, generating volumetric-modulated arc therapy plans combined with simultaneous integrated boost technique VMAT (SIB-VMAT) for locally advanced rectal cancer (LARC) patients. Method: The designed AIP system aimed to automate the entire planning process through a web-based service, including auxiliary structure generation, plan creation, field configuration, plan optimization, dose calculation, and plan assessment. The system was implemented based on the Eclipse scripting application programming interface and an efficient iterative optimization algorithm was proposed to reduce the required iterations in the optimization process. To verify the performance of the implemented AIP system, we retrospectively selected a total of 106 patients and performed dosimetric comparisons between the automatic plans (APs) and the manual plans (MPs), in terms of dose-volume histogram (DVH) metrics, homogeneity index (HI), and conformity index (CI) for different volumes of interest. Result: The AIP system has successfully created 106 APs within clinically acceptable timeframes. The average planning time per case was 36.8 +/- 6.5 min, with an average iteration number of 6.8 (+/- 1.1) in plan optimization. Compared to MPs, APs exhibited better performance in the planning target volume conformity and hotspot control (p<0.001$p < 0.001$). The organs at risk (OARs) sparing was significantly improved in APs, with mean dose reductions in the femoral heads, the bone marrow, and the SmallBowel-Avoid of 0.53 Gy, 1.18 Gy, and 1.00 Gy, respectively (p<0.001$p < 0.001$). Slight improvement was also observed in the urinary bladder V40Gy${{V}_{40{\mathrm{\ Gy}}}}$ and the small bowel D2cc(p<0.001)${{D}_{2{\mathrm{\ cc}}}}\ (p < 0.001)$. Additionally, quality variation between plans from different planners was observed in DVH metrics while the APs represented better plan quality consistency. Conclusion: An AIP system has been implemented and integrated into the clinical treatment planning workflow. The AIP-generated SIB-VMAT plans for LARC have demonstrated superior plan quality and consistency compared with the manual counterparts. In the meantime, the planning time has been reduced by the AIP approach. Based on the reported results, the implemented AIP framework has been proven to improve plan quality and planning efficiency, liberating planners from the laborious parameter-tuning in the optimization phase.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Planning comparison of five automated treatment planning solutions for locally advanced head and neck cancer
    Krayenbuehl, J.
    Zamburlini, M.
    Ghandour, S.
    Pachoud, M.
    Lang-Tanadini, S.
    Tol, J.
    Guckenberger, M.
    Verbakel, W. F. A. R.
    RADIATION ONCOLOGY, 2018, 13 : 170
  • [22] Automatic treatment planning of VMAT for left-sided breast cancer with lymph nodes
    Engstrom, Kenni Hojsgaard
    Brink, Carsten
    Nielsen, Mette Holck
    Kjellgren, Martin
    Gottlieb, Karina
    Hazell, Irene
    Hansen, Vibeke Nordmark
    Lorenzen, Ebbe Laugaard
    ACTA ONCOLOGICA, 2021, 60 (11) : 1425 - 1431
  • [23] Investigating VMAT Planning Technique to Reduce Rectal and Bladder Dose in Prostate Cancer Treatment Plans
    Rana, S.
    Cheng, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Investigating VMAT planning technique to reduce rectal and bladder dose in prostate cancer treatment plans
    Rana, Suresh B.
    Cheng, ChihYao
    CLINICAL CANCER INVESTIGATION JOURNAL, 2013, 2 (03): : 212 - 217
  • [25] Correction to: Planning comparison of five automated treatment planning solutions for locally advanced head and neck cancer
    J. Krayenbuehl
    M. Zamburlini
    S. Ghandour
    M. Pachoud
    S. Tanadini-Lang
    J. Tol
    M. Guckenberger
    W. F. A. R. Verbakel
    Radiation Oncology, 13
  • [26] Comparison of endorectal ultrasound versus pelvic magnetic resonance imaging for radiation treatment planning in locally advanced rectal cancer
    Yu, Esther
    DiPetrillo, Thomas A.
    Ramey, Steven
    Leonard, Kara L.
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (05) : E451 - E455
  • [27] Preoperative VMAT with simultaneous integrated boost for locally advanced distal rectal cancer
    Yang, Y.
    Liu, Q.
    Zhao, P.
    Qian, J.
    Peng, Q.
    Zhu, Y.
    Feng, L.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S785 - S786
  • [28] Radiomics features on radiotherapy treatment planning CT can predict patient survival in locally advanced rectal cancer patients
    Jiazhou Wang
    Lijun Shen
    Haoyu Zhong
    Zhen Zhou
    Panpan Hu
    Jiayu Gan
    Ruiyan Luo
    Weigang Hu
    Zhen Zhang
    Scientific Reports, 9
  • [29] Radiomics features on radiotherapy treatment planning CT can predict patient survival in locally advanced rectal cancer patients
    Wang, Jiazhou
    Shen, Lijun
    Zhong, Haoyu
    Zhou, Zhen
    Hu, Panpan
    Gan, Jiayu
    Luo, Ruiyan
    Hu, Weigang
    Zhang, Zhen
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [30] Algorithm for an automatic treatment planning system using a single-arc VMAT for prostate cancer
    Kodama, Takumi
    Kudo, Shigehiro
    Hatanaka, Shogo
    Hariu, Masatsugu
    Shimbo, Munefumi
    Takahashi, Takeo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (12): : 27 - 36